Colorimetric system for online monitoring of water and wastewater treatment
Highly robust gas specialist for fluctuating conditions with compact, easily accessible transmitter
Highest capacity four-tube flowmeter with a compact, easily accessible transmitter
The specialist for life sciences with an ultra-compact transmitter
Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy
Inline flowmeter with long-term stability and a compact, easily accessible transmitter
Versatile standard flowmeter for the water and wastewater industry
Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter
The specialist for hygienic applications with an ultra-compact transmitter
Dual channel, SIL compliant temperature transmitter for use in hazardous areas
Trend-setting, highly modular and intrinsically safe RTD or TC thermometer – for a wide range of industrial applications
Universal, high-performance tablet PC for device configuration
Universal, high-performance tablet PC for device configuration
Universal transmitter, loop power supply, barrier and limit switch in one device!
For the indication of the 4 to 20 mA signal or the HART® values in the field or in the
Custody transfer BTU meter for recording heat quantities of water
Smart pressure transmitter - its health can be verified without process interruption
Smart pressure transmitter which detects process anomalies like plugged impulse lines
Bridge your application from the laboratory to the process environment
Precise composition measurement of high-speed, low volume samples for downstream optimization
Maintain sterility and spectral quality while reducing maintenance and cleaning burdens
Protect your samples with contact-free measurement
Continuous, inline, multi-component bioprocess measurement
Unlock the power of in situ laboratory analysis of liquids, slurries, and semi-solids
Innovative Raman fiber optics designed for maximum laser safety and easy installation
Reliable H2S measurement for increased quality, process control, and asset integrity
Proven technology for accurate and reliable measurement of H2O in natural gas
World's only intrinsically safe HART/USB interface for Device & FieldCare and FieldXpert software
Point level switch for all liquid media
Smart Safety for your process
Memosens 2.0 pH electrode for standard applications in process and water & wastewater industries
Universal assembly for the water and wastewater industry and industrial auxiliary processes.
Expandable multiparameter field device for all industries

Ammonium analyzer Liquiline System CA80AM

Colorimetric system for online monitoring of water and wastewater treatment

  • Measuring principle

    Colorimetric

  • Characteristic

    Analyzer for ammonium in aqueous solutions

  • Measuring method

    Comply with standard colorimetric measuring principle – indophenol blue method following ISO 7150-1, DIN 38406-5 and GB 7481-87

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design / cabinet:
    Plastic ASA-PC
    Stand housing:
    Plastic ASA-PC, steel coated

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    Unpressurized

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Low solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    Optional cooling module for longer reagent life time
    Automatic calibration and cleaning
    Optional 2 channel version
    User-definable measuring ranges
    Flexibale functionality and modular expandable
    Digital communication for remote access

  • Application

    Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
    Monitoring of the wastewater treatment plant outlet for documentation purposes
    Monitoring and optimization of activated sludge basins

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1.2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Optional: Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 or 2 measuring channels
    Optinonal 1 to 4 digital sensor inputs for sensors with Memosens protocol

  • Measurement range

    0.05 to 20 mg/l NH4-N
    0.5 to 50 mg/l NH4-N
    1 to 100 mg/l NH4-N
    0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l NH4-N

  • Consumables

    Reagents and standard solutions CY80AM
    Cleaner CY800
    Maintenance kit CAV800

Field of application
Liquiline System CA80AM offers high-precision ammonium measurement in all critical control points. As member of the Liquiline platform, it enables plug & play and easy upgrade to a measuring station – minimizing the installation effort. Automatic calibration and cleaning as well as the low consumption of reagents save you operating and maintenance costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.

Liquiline System CA80AM monitors and controls:
Inlets of wastewater treatment plants
Outlets of wastewater treatment plants for documentation purposes
Aeration basins
Water treatment
Cleaning capacity of municipal and industrial wastewater plants

Benefits
Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensorsAdvanced diagnostics with remote access for increased process safetyReduced operating costs through automatic, configurable calibration and cleaning and long reagent shelf life with optional cooling moduleCompliance with standard colorimetric measuring principle – indophenol blue method – following ISO 7150-1, DIN 38406-5 and GB 7481-87

Proline Prosonic Flow G 300 ultrasonic flowmeter

Highly robust gas specialist for fluctuating conditions with compact, easily accessible transmitter

  • Measuring principle

    Ultrasonic flow

  • Product headline

    Highly robust gas specialist for fluctuating process conditions with compact, easily accessible transmitter.
    Flexible device with user-definable gas mixtures for demanding measuring tasks.
    Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.

  • Sensor features

    Maximum reliability even with humid or wet gas – sensor design insensitive to condensate. High-performance process control – real-time pressure- and temperature-compensated values. Efficient solution – multivariable, no pressure loss.
    Direct measurement: flow, pressure & temperature. Wetted parts: titanium / 316L. Maximum measuring accuracy: 0.5 %.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

  • Nominal diameter range

    DN 25 to 300 (1 to 12″)

  • Wetted materials

    Measuring tube: 1.4408/1.4409 (CF3M)
    Transducer: 1.4404 (316, 316L), Titan Grade 2

  • Measured variables

    Volume flow, corrected volume flow, mass flow, flow velocity, speed of sound, pressure, temperature, density, dynamic viscosity, energy flow, Wobbe index, methane fraction, calorific value, molar mass

  • Max. measurement error

    Volume flow (standard):
    ‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
    ‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
    Volume flow (optional calibration):
    ‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
    ‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
    Corrected volume flow (standard):
    ‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
    ‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
    Corrected volume flow (optional calibration):
    ‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
    ‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
    Sound Velocity: ±0.2 % o.r.

  • Measuring range

    Gas: 0.3 m/s to 40 m/s

  • Max. process pressure

    0.7 to 101 bar a (10.15 to 1464.88 psi a)

  • Medium temperature range

    -50 to 150 °C (-58 to +302°F)
    -50 to 100 °C (-58 to +212°F) with integrated pressure cell

  • Ambient temperature range

    -40 to 60 °C(-40 to +140 °F)
    Optional: -50 to 60 °C(-58 to +140 °F)

  • Sensor housing material

    Stainless Steel, 1.4404(316/316L), 1.4408/1.4409 (CF3M)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
    Polycarbonate

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure.
    Optional: External WLAN antenna: IP67

  • Display/Operation

    4-line backlit display with Touch Control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, Modbus RS485

  • Power supply

    24V DC
    100 to 230 V AC
    AC 100 to 230 V / DC 24 V (non harzardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC

  • Product safety

    CE, C-tick

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material
    NACE MR0175/MR0103

Field of application
For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables compliance and process safety at all times.

The measuring principle is unaffected by gas compositionAccurate measurement of natural and process gas in the chemical as well as oil and gas industries.Device properties:Direct measurement: flow, pressure & temperatureWetted parts: titanium / 316LMaximum measuring accuracy: 0.5 %Compact dual-compartment housing with up to 3 I/OsBacklit display with touch control and WLAN accessRemote display available

Benefits
Flexible device with user-definable gas mixtures for demanding measuring tasks
Maximum reliability even with humid or wet gas – sensor design insensitive to condensateHigh-performance process control – real-time pressure- and temperature-compensated values
Efficient solution – multivariable, no pressure loss
Full access to process and diagnostic information – numerous, freely combinable I/Os
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology

Proline Promass X 300 Coriolis flowmeter

Highest capacity four-tube flowmeter with a compact, easily accessible transmitter

  • Measuring principle

    Coriolis

  • Product headline

    Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.
    For highest flow rates and outstanding performance in on/offshore oil and gas applications.

  • Sensor features

    Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Nominal diameter: DN 300 to 400 (12 to 16″). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L).

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Compact dual-compartment housing with up to 3 I/Os.

  • Nominal diameter range

    DN 300 to 400 (12 to 16″)

  • Wetted materials

    Measuring tube: 1.4404 (316/316L)
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 4100 t/h (0 to 4520 tn. sh./h)

  • Max. process pressure

    PN 100, Class 600

  • Medium temperature range

    –50 to +180 °C (–58 to +356 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L

  • Degree of protection

    IP66/67, type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available”

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
    MI-002, PTB

  • Marine approvals and certificates

    LR approval, DNV approval, ABS approval, BV approval, CCS approval

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

  • Measuring principle

    Coriolis

  • Product headline

Proline Promass P 100 Coriolis flowmeter

The specialist for life sciences with an ultra-compact transmitter

  • Measuring principle

    Coriolis

  • Product headline

    Specialist for life sciences with an ultra-compact transmitter.
    Dedicated to applications under sterile conditions in the life sciences industry.

  • Sensor features

    Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). Fast recovery from CIP/SIP.

  • Transmitter features

    Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
    Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2″)

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4435 (316L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Max. process pressure

    PN 63, Class 300, 40K

  • Medium temperature range

    Standard: –50 to +150 °C (–58 to +302 °F)
    Option: –50 to +205 °C (–58 to +401 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Compact: AlSi10Mg, coated
    Compact/ultra‐compact: 1.4301 (304)

  • Degree of protection

    Standard: IP66/67, type 4X enclosure
    Option: IP69

  • Display/Operation

    4‐line backlit display available (no local operation)
    Configuration via web browser and operating tools possible

  • Outputs

    4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)

  • Inputs

    None

  • Digital communication

    HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

  • Power supply

    DC 20 to 30 V

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

  • Product safety

    CE, C-Tick, EAC marking

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation)

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, EHEDG, ASME BPE, ISPE, cGMP

  • Measuring principle

    Coriolis

  • Hygienic approvals and certificates

    cGMP

  • Measuring principle

    Coriolis

  • Product headline

    Specialist for life sciences with an ultra-compact transmitter.
    Dedicated to applications under sterile conditions in the life sciences industry.

  • Sensor features

    Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). Fast recovery from CIP/SIP.

  • Transmitter features

    Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. I

Proline Prowirl F 200 vortex flowmeter

Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy

  • Measuring principle

    Vortex

  • Product headline

    Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.
    Easy energy management – integrated temperature and pressure measurement for steam and gases.
    Suitable for a wide range of applications; optimized for steam applications.

  • Sensor features

    Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
    Wet steam capabilities for DN 25 to 300 (1 to 12″). Flexible positioning of pressure cell. Industrial siphon design for pressure measurement.

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
    Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

  • Nominal diameter range

    DN 15 to 300 (½ to 12″)

  • Wetted materials

    Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
    DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
    Process connection: 1.4404/F316/F316L); 2.4602

  • Measured variables

    Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

  • Max. measurement error

    Volume flow (liquid): ±0.75 %
    Volume flow (optional): ±0.65 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
    Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
    Mass flow (liquid): ±0.85%

  • Measuring range

    Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

  • Max. process pressure

    PN 100, Class 600, 20K

  • Medium temperature range

    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)

  • Ambient temperature range

    Compact version (standard): –40 to +80 °C (–40 to +176 °F)
    Compact version (option): –50 to +80 °C (–58 to +176 °F)
    Remote version (standard): –40 to +85 °C (–40 to +185 °F)
    Remote version (option): –50 to +85 °C (–58 to +185 °F)

  • Sensor housing material

    Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4404 (316L)

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

  • Inputs

    Current Input 4‐20 mA (passive)

  • Digital communication

    HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Power supply

    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, JPN, EAC

  • Product safety

    CE, C-TICK, EAC, UK Ex

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Marine approvals and certificates

Proline t-mass F 300 thermal mass flowmeter

Inline flowmeter with long-term stability and a compact, easily accessible transmitter

  • Measuring principle

    Thermal

  • Product headline

    Inline flowmeter with long-term stability and a compact, easily accessible transmitter.
    Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof.
    Measurement of utility and process gases as well as gas mixtures in small line sizes.

  • Sensor features

    High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor.
    Inline version with DN 15 to 100 (½ to 4″). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

  • Nominal diameter range

    DN 15 to DN 100 (1/2″ to 4″)

  • Wetted materials

    Measuring tubes
    DN 15 to 50 (½ to 2″): stainless cast steel, CF3M/1.4408
    DN 65 to 100 (2½ to 4″): stainless steel, 1.4404 (316/316L)
    Process connections
    Flange connections
    Stainless steel, 1.4404 (F316/F316L)
    Threaded connections
    Stainless steel, 1.4404 (316/316L)
    Sensing element
    Unidirectional
    Stainless steel, 1.4404 (316/316L)
    Alloy C22, 2.4602 (UNS N06022);
    Bidirectional
    Stainless steel, 1.4404 (316/316L)
    Reverse flow detection
    Stainless steel, 1.4404 (316/316L)

  • Measured variables

    Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density

  • Max. measurement error

    Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

  • Measuring range

    0.5 to 3750 kg/h (1.1 to 8250 lb/h)

  • Max. process pressure

    PN40 / Cl. 300 / 20K

  • Medium temperature range

    -40 °C to +180°C (-40 °F to +356 °F)

  • Ambient temperature range

    -40 to 60°C (-40 to 140°F)
    Optional:
    Transmitter: -50 to 60°C (-50 to 140°F),
    Sensor: -60 to 60°C (-60 to 140°F)

  • Transmitter housing material

    Aluminium, AlSi10Mg, coated
    Polycarbonate

  • Degree of protection

    IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, Modbus RS485

  • Power supply

    DC 24V
    AC 100 to 240V

  • Hazardous area approvals

    ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC

  • Product safety

    CE, C-tick

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material
    NACE MR0175/MR0103

Field of application
The patented sensor design of t-mass F provides unprecedented measurement stability in thermal mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. Its compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.

Measuring principle is characterized by a high operable flow range and direct mass flow measurementMeasur

Proline Promag W 400 electromagnetic flowmeter

Versatile standard flowmeter for the water and wastewater industry

  • Measuring principle

    Electromagnetic

  • Product headline

    Versatile standard flowmeter for the water and wastewater industry.
    Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
    Ideal for water measurement, e.g. drinking water, utility water and industrial/municipal wastewater.

  • Sensor features

    Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
    International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). Approved for custody transfer to MI-001/OIML R49.

  • Transmitter features

    Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
    Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring.

  • Nominal diameter range

    DN 25 to 3000(1 to 120″)

  • Wetted materials

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
    Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

  • Measured variables

    Volume flow, conductivity, mass flow

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

  • Measuring range

    0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
    Liner material PTFE: –20 to +90 °C (–4 to +194 °F)

  • Ambient temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)

  • Sensor housing material

    DN 25 to 300 (1 to 12″): AlSi10Mg, coated
    DN 25 to 2000 (1 to 78″): Carbon steel with protective varnish
    Sensor connection housing (standard): AlSi10Mg, coated
    Sensor connection housing (option): Polycarbonate

  • Transmitter housing material

    Polycarbonat; AlSi10Mg, coated

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP68, type 6P enclosure, with protective varnish
    according to EN ISO 12944 C5‐M/Im1/Im2/Im3
    Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display, web browser and operating tools possible

  • Outputs

    3 ouputs:
    0‐20 mA/4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)
    Pulse/frequency output (passive)
    Switch output (passive)

  • Inputs

    Status input

  • Digital communication

    HART, PROFIBUS DP, EtherNet/IP, Modbus RS485

  • Power supply

    AC 100…240 V / AC/DC 24 V

  • Hazardous area approvals

    cCSAus

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
    Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run)

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920

Field of application
With its international approvals for custody transfer as well as drinking water, Promag W serves the broadest variety of applications. It is available as both compact or remote version. Promag W 400 saves time and costs thanks to the broad functionality of its transmitter optimized for Water & Wastewater. In addition, Heartbeat Technology enables measurement reliability and compliant verification.

The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityIdeal for water measurement , e.g. drinking water, utility water and industrial/municipal wastewaterDevice propertiesInternational drinking water approvalsDegree of protection IP68 (Type 6P enclosure)Approved for custody transfer to MI-001/OIML R49Transmitter housing made of durable polycarbonate or aluminiumWLAN accessIntegrated data logger: measured values monitoring

Benefits
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure lossFlexible engineering – sensor with fixed or lap-joint process connectionsApplication fitness – EN ISO 12944 corrosion protection for underground or underwater installationImproved plant availability – sensor compliant with industry-specific requirementsSafe operation – no need to open the deviceTime-saving local operation without additional software and hardware – integrated web serverIntegrated verification and build-up detection – Heartbeat Technology

Proline Promag W 300 electromagnetic flowmeter

Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter

  • Measuring principle

    Electromagnetic

  • Product headline

    Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter.
    Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
    Dedicated to the measurement of industrial or municipal water and wastewater .

  • Sensor features

    Flexible engineering – sensor with fixed or lap-joint process connections. Long-term operation – robust and completely welded sensor. Improved plant availability – sensor compliant with industry-specific requirements.
    International drinking water approvals.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

  • Nominal diameter range

    DN 25 to 3000(1 to 120″)

  • Wetted materials

    Liner: Polyurethane; Hard rubber, PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

  • Measured variables

    Volume flow, conductivity, mass flow

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

  • Measuring range

    0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
    Liner material PTFE: –20 to +90 °C (–4 to +194 °F)

  • Ambient temperature range

    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    DN 25 to 300 (1 to 12″): AlSi10Mg, coated
    DN 25 to 2400 (1 to 90″): Carbon steel with protective varnish
    Sensor connection housing (standard): AlSi10Mg, coated
    Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input 4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Marine approvals and certificates

    LR approval, DNV approval, ABS approval, BV approval

  • Pressure approvals and certificates

    CRN, PED

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    ACS, KTW/W270, NSF 61, WRAS BS 6920

Field of application
The premium device for water and wastewater measurement Promag W 300 was designed for reliable use in hazardous areas and under harsh conditions. Its compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.

The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated to the measurement of industrial or municipal water and wastewaterDevice propertiesInternational drinking water approvalsDegree of protection IP68 (Type 6P enclosure)Compact dual-compartment housing with up to 3 I/OsBacklit display with touch control and WLAN accessRemote display available

Benefits
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure lossFlexible engineering – sensor with fixed or lap-joint process connectionsLong-term operation – robust and completely welded sensorImproved plant availability – sensor compliant with industry-specific requirementsFull access to process and diagnostic information – numerous, freely combinable I/Os and EthernetReduced complexity and variety – freely configurable I/O functionalityIntegrated verification – Heartbeat Technology

Proline Promag H 100 electromagnetic flowmeter

The specialist for hygienic applications with an ultra-compact transmitter

  • Measuring principle

    Electromagnetic

  • Product headline

    Specialist for hygienic applications with an ultra-compact transmitter.
    Multivariable measurement of flow, temperature and conductivity.
    Dedicated to demanding applications in the food and beverage as well as in life sciences industries.

  • Sensor features

    Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
    Integrated temperature measurement. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP, SIP cleanable.

  • Transmitter features

    Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
    Robust, ultra-compact transmitter housing. High degree of protection: IP69. Local display available.

  • Nominal diameter range

    DN 2 to 150 (¹⁄₁₂ to 6″)

  • Wetted materials

    Liner: PFA
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
    Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
    Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
    Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum

  • Measured variables

    Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
    conductivity

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
    Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

    0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)

  • Max. process pressure

    PN 40, Class 150, 20K

  • Medium temperature range

    –20 to +150 °C (–4 to +302 °F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Compact: AlSi10Mg, coated
    Compact/ultra‐compact: 1.4301 (304)

  • Degree of protection

    Standard: IP66/67, type 4X enclosure
    Option: IP69

  • Display/Operation

    4‐line backlit display available (no local operation)
    Configuration via web browser and operating tools possible

  • Outputs

    4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)

  • Inputs

    None

  • Digital communication

    HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET

  • Power supply

    DC 20 to 30 V

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, INMETRO, EAC

  • Product safety

    CE, C-tick

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation)

  • Marine approvals and certificates

    LR approval, DNV approval, ABS approval, BV approval

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP

Field of application
Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. The ultra-compact transmitter provides full performance on the smallest footprint and enables seamless system integration, making Promag H 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.

The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated to demanding applications in the food and beverage as well as in life sciences industriesDevice propertiesIntegrated temperature measurementSensor housing made of stainless steel (3-A, EHEDG)Wetted materials CIP, SIP cleanableRobust, ultra-compact transmitter housingHigh ingress protection: IP69Local display available

Benefits
Multivariable measurement for flow, temperature and conductivityFlexible installation concept – numerous hygienic process connectionsEnergy-saving flow measurement – no pressure loss due to cross-section constrictionSpace-saving transmitter – full functionality on the smallest footprintTime-saving local operation without additional software and hardware – integrated web serverIntegrated verification – Heartbeat TechnologyMaintenance-free – no m

iTEMP TMT82 HART® 7 temperature transmitter

Dual channel, SIL compliant temperature transmitter for use in hazardous areas

  • Measuring principle

    Head transmitter

  • Input

    2 x RTD, TC, Ohm, mV

  • Output

    1 x analog 4…20 mA / HART

  • Auxiliary power supply

    11…42 V DC (head transmitter)
    12…42 V DC (Din rail device)
    11/12…30 V DC (Ex ia)

  • Communication

    HART-protocol

  • Installation

    Terminal head form B, DIN-Rail housing or field mount housing

  • Accuracy

    (Pt100, -50…200 °C) <= 0,1 K
    (Pt100, -58…392 °F) <= 0,18 °F

  • Galvanic isolation

    yes

  • Certification

    ATEX II1G Ex ia IIC T4/T5/T6
    ATEX II3G Ex ic IIC T6 Gc
    ATEX II2D Ex tb IIIC Db
    ATEX II3D Ex tc IIIC Dc
    ATEX II3G Ex nA IIC T6 Gc
    ATEX II1G Ex ia IIC T6 Ga, II3D
    ATEX II3G Ex nA IIC T6 Gc, II3D
    ATEX II2G Ex d T6, II2D Ex tb IIIC
    CSA C/US General Purpose
    CSA IS, NI I / 1+2/A-D
    CSA XP, NI, DIP I, II, III/1+2/A-G
    FM IS,NI I / 1+2/A-D
    FM XP, NI, DIP I, II, III/1+2/A-G
    EAC Ex ia IIC T6 Ga
    EAC Ex d IIC T6 Gb
    EAC Ex ia IIC T6, II3D
    IECEx Ex ia IIC T4/T5/T6
    IECEx Ex tb IIIC Db
    IECEx Ex nA II T4/T5/T6
    IECEx Ex d T6 Gb, Ex tb IIIC Db
    INMETRO Ex ia [ia Ga] IIC T6 Gb
    INMETRO Ex d T6 Gb, Ex tb IIIC Db
    NEPSI Ex ia IIC T6 Ga
    NEPSI Ex d IIC T6 Gb
    NEPSI Ex nA IIC T6 Gc
    TIIS Ex ia IIC T6
    TIIS Ex nA II T6
    UK II1G Ex ia IIC T6 Ga
    UK II2D Ex tb IIIC Db
    UK II3D Ex tc IIIC Dc
    UK II1G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
    UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
    UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
    ATEX IECEx II1G Ex ia IIC T6 Ga
    FM+CSA IS, NI I/1+2/A-D

Field of application
The iTEMP TMT82 is a highly reliable, accurate and long-term stable temperature transmitter for industrial processes requiring high availability. The versatile 2-channel device converts universal sensor inputs such as thermocouples or RTD into stable, scalable 4 to 20 mA output signals and HART® communication. With its built-in smart sensor monitoring capability and diagnostic status information according to NAMUR NE 107, the SIL 2, SC3 certified transmitter increases process safety and uptime.

Safe operation in hazardous areas; International approvals such as FM, CSA, ATEX, EAC, NEPSI, IECEx, DNV GL 2-channel universal signal inputs: RTD, thermocouple, resistance (Ω) and voltage transmitters (mV), HART® 7 protocolSuited for use in marine applicationsInstallation in explosion proof field housings; Protection class up to IP 68Fits in flat-face terminal heads as per DIN EN 50446Cabinet or DIN rail mounting; width: 17.5 mm

Benefits
Robust temperature transmitter delivering precise, long-term stable measurements for high plant availabilitySIL certification up to SIL2, SC3 according to IEC 61508:2010Versatile mounting and housing options:terminal head form B, DIN rail, field housing with separate terminal compartment, integrated display (TID10)Transmitter-sensor matching for highest measurement accuracySensor and hardware failure detection; diagnostic status informationaccording to NAMUR NE 107Time-saving installation: Tool-free wiring with push-in terminal technology

Intrinsically Safe Temperature Sensor: iTHERM ModuLine TM131

Trend-setting, highly modular and intrinsically safe RTD or TC thermometer – for a wide range of industrial applications

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    modular temperature assembly
    universal range of application
    suitable for hazardous areas
    with neck or QuickNeck
    incl. thermowell / protection tube (metal) or to be installed into thermowell
    can be used with StrongSens, QuickSens insert
    for fast response times

  • Thermowell / protection tube

    welded protection tube or to be used with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    Thermowell:
    9×1,25 mm
    11×2 mm
    12×2,5 mm
    14×2 mm
    16×3,5
    1/4″ SCH80
    1/2″ SCH80
    1/2″ SCH40

  • Max. immersion length on request

    up to 4.500,0 mm (177”)

  • Material protection tube/ thermowell

    316 (1.4401)
    316L (1.4404)
    316Ti (1.4571)
    Alloy 600 (2.4816)
    Alloy C276 (2.4819)
    Alloy 446 (1.4749)
    Alloy 321 (1.4541)
    Sheath PTFE
    Sheath Tantal

  • Process connection

    Male thread:
    G3/8, G1/2″, G3/4″, G1″
    NPT1/2″, NPT3/4″, NPT 1″
    M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
    R1/2″, R3/4″
    Female thread:
    M20x1.5, M24x1.5
    NPT1/2″
    Cap-nut:
    M20x1.5, G1/2″, G3/4″
    Compression fitting:
    NPT1/2″, G1/2″, G1″
    Flange:
    DN15 PN40 B1, C
    DN25 PN20, PN40, PN100 B1, B2, C
    DN40 PN40 B1
    DN50 PN40 B1
    ASME 1″ 150 RF
    ASME 1″ 300 RF
    ASME 1 1/2″ 150 RF
    ASME 2″ 150 RF
    ASME 2″ 300 RF

  • Tip shape

    straight
    reduced
    tapered
    optimized for quick response times

  • Surface roughness Ra

    < 0.76 μm (0.03 μin)

  • Operating temperature range

    PT100 TF StrongSens:
    -50 °C …500 °C
    (-58 °F …932 °F)
    PT100 QuickSensTF:
    -50 °C …200 °C
    (-58 °F …392 °F)
    PT100 WW:
    -200 °C …600 °C
    (-328 °F …1.112 °F)
    PT100 TF:
    -50 °C …400 °C
    (-58 °F …752 °F)
    Typ K:
    max. 1.100 °C
    (max. 2.012 °F)
    Typ J:
    max. 800 °C
    (max. 1.472 °F)
    Typ N:
    max. 1.100 °C
    (max. 2.012 °F)

  • Max. process pressure (static)

    depending on the configuration up to 100 bar

  • Accuracy

    Class AA acc. to IEC 60751
    Class A acc. to IEC 60751
    Class B acc. to IEC 60751
    Class special or standard acc. to ASTM E230
    Class 1 or 2 acc. to IEC 60584-2

  • Response time

    fastest response time with thermowell t90 starting at below 10 s
    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex – approvals

    ATEX
    ATEX IECEx
    NEPSI
    IECEx
    EAC Ex
    CSA C/US
    INMETRO

  • Certification

    SIL, MID, DNV/GL

Field of application
Intrinsically safe temperature sensor (RTD / TC assembly) with manufactured thermowell or for use with existing thermowell. An optional head transmitter with all common communication protocols – Bluetooth® technology inclusive – and special features like iTHERM QuickNeck for tool-free, easy recalibration, vibration-resistant and fast-response sensor and thermowell technology (iTHERM StrongSens, QuickSens) as well as hazardous area approvals ensure enhanced measurement accuracy and reliability.

Universal range of applicationMeasuring range: –200 to +1.100 °C (–328 to +2.012 °F)Pressure range up to 100 bar (1450 psi)Degree of protection: up to IP 68Vibration-resistant sensor elements up to 60gImproved ease of maintenance (sensor replacement without process shutdown), easy and safe recalibration of the measuring point

Benefits
Second process barrier with failure indication offering valuable health status information iTHERM QuickSens: fastest response times 1.5 s for optimum process control iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety iTHERM QuickNeck: cost and time savings thanks to simple, tool-free recalibrationBluetooth® connectivity (optional) International certification: explosion protection according to ATEX, IECEx, CSA C/US and NEPSI

Field Xpert SMT70

Universal, high-performance tablet PC for device configuration

  • Measuring principle

    Device configurator

  • Function

    The Field Xpert SMT70 tablet PC for universal device configuration supports protocols such as HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus, and Endress+Hauser service protocols (CDI, ISS, IPC and PCP). The devices can be connected directly via a suitable interface e.g. a modem (point-to-point) or a bus system (point-to-bus).

  • Input

    Camera:
    • 5 MP camera on the back with auto focus and LED flash with 1500 mcd
    • 2 MP camera on the front
    Scanner:
    • 1D/2D barcode scanner

  • CPU

    Intel Core i5-5200U (2,2…2,7 GHz)

  • Memory

    • 8 GB with DDR3L adapter
    • 256 GB SSD M2-SATA robust version
    • Micro SD card slot, support for SDHC/SDXC

  • Power supply

    Replaceable, rechargeable lithium polymer battery, 11.1 VDC,
    4100 mAh (45 Wh)/7800 mAh (86 Wh) (optional)

  • Dimensions (WxHxD)

    298.5 mm x 192 mm x 20 mm
    (11.4 in x 7.48 in x 0.78 in)

  • Screen size

    • 11.6″ LCD display, with Gorilla Glass protector
    • Capacitive multi-touch screen
    • Optical bonding, sunlight readable, LCD (730 Nit)
    • Ambient light sensor

  • Resolution

Field Xpert SMT50

Universal, high-performance tablet PC for device configuration

  • Measuring principle

    Device configurator

  • Function

    The Field Xpert SMT50 tablet PC for universal device configuration supports various protocols, the Endress+Hauser service protocols and connection to Endress+Hauser Bluetooth field devices. Field devices can be connected directly via suitable interface, e.g. a modem (point-to-point) or a bus system (point-to-bus) or wireless (WLAN/Bluetooth).

  • Input

    2 MP camera on the front
    5 MP camera or better, on the rear

  • CPU

    Intel® Skylake Core m3-6Y30 or better

  • Memory

    Working memory: 4 GB DDR3L
    Memory 128 GB M.2 SSD

  • Power supply

    Replaceable, rechargeable lithium polymer battery, 7,4 VDC, 6300 mAh (45 Wh)

  • Dimensions (WxHxD)

    11.75 in ⋅ 8.5 in ⋅ 0.9 in

  • Screen size

    12.2″”
    Touch Screen: 10-point capacitive (Corning Gorilla Glass 3)
    Brightness: 280 cd/m²

  • Resolution

    1920 × 1200 pixels

  • Communication interface

    2x USB 2.0 + 1x USB 3.0
    802.11 a/b/g/n | 2.4GHz + 5.8GHz Dual Band Wi-Fi
    Bluetooth 4.0 (BLE) Class 1.5 | Transmission distance: 10 meters
    Integrated 4G module + U-blox NEO-7

  • Operation

    Operating system: Windows 10 LTSC

  • Configuration

    Touch-enabled device configuration software optimized for Field Xpert that is characterized by easy, fast and intuitive operation. The Field Xpert device library has more than 3000 preinstalled device and communication drivers. They can be used to operate practically all HART and FOUNDATION Fieldbus devices (FieldComm Group libraries). Furthermore all Endress+Hauser field device drivers are installed. Further device drivers (DTMs) can be installed additionally. The generic HART DTM and PROFIBUS profile DTMs also enable operation of all the important basic functionalities of the relevant field devices.

  • Optional

    4G LTE WWAN + 12 channel GPS

  • Certificates

    Degree of protection:
    IP65
    Vibration resistance:
    MIL-STD 810G 514.6 Procedure I Cat. 24, Fig. 514.6E-1
    Shock resistance:
    MIL-STD-810G
    Interference conformance to:
    EN 55022: 2010+ AC: 2011
    EN 55022 Class B
    EN 61000-3-2
    EN 61000-3-3
    Interference immunity:
    EN 55024: 2010
    IEC 61000-4-2
    IEC 61000-4-3
    IEC 61000-4-4
    IEC 61000-4-5
    IEC 61000-4-6
    IEC 61000-4-8
    IEC 61000-4-11
    Approvals:
    CE, FCC”

Field of application
The Field Xpert SMT50 tablet PC for universal device configuration supports various protocols, the Endress+Hauser service protocols and connection to Endress+Hauser Bluetooth field devices. Field devices can be connected directly via suitable interface, e.g. a modem (point-to-point) or a bus system (point-to-bus) or wireless (WLAN/Bluetooth). The Field Xpert software package is fast, easy and intuitive to use. Its device library has more than 3000 pre-installed device and communication drivers.

The Field Xpert SMT50 tablet PC for device configuration enables mobile plant asset management in non-hazardous areas. It is suitable for commissioning and maintenance. It manages Endress+Hauser and third-party instruments with a digital communication interface and documents the progress of the work. The SMT50 is designed as a complete solution. It comes with a pre-installed driver library and is an easy-to-use, touch-enabled tool for managing field devices throughout their entire life cycle.

Benefits
Robust tablet with large 12″ display and a battery runtime of up to 8 hours.Touch-enabled device configuration software for optimized asset management.Direct link to Netilion, Endress+Hauser’s IIoT ecosystem.Pre-installed device driver libraries for all of the important industrial protocols.Fast connection to devices with a single click thanks to automatic hardware detection. Online application software and DTM/Drivers update service offers new functionality and maximum security.Integrated Heartbeat Verification incl. PDF documentation.Connection to Endress+Hauser Bluetooth and WLAN devices – perfect for difficult-to-access instruments.

RMA42 Process transmitter with control unit

Universal transmitter, loop power supply, barrier and limit switch in one device!

  • Measuring principle

    Process transmitter

  • Measuring principle

    Process transmitter

  • Function

    Universal process and temperature transmitter with control unit

  • Loop power supply

    24 V intrinsically safe loop power supply

  • Power Supply

    Wide range power supply 24 to 230 V AC/DC (-20 % / +10 %) 50/60 Hz

  • Input

    2 x universal (current, voltage, R, RTD, TC, resistance)

  • Output

    2 x Analog (current, voltage)

  • Software functions

    Internal software for calculations, linearization, limit monitoring
    Monitoring of sensor wires according NAMUR NE43
    Application package differential pressure measurement

  • Certificates

    ATEX
    FM
    NEPSI
    CSA
    UKCA
    UR C/US
    marine approval
    KTA
    German WHG overfill protection

  • SIL

    2

  • Display

    LCD
    7 segment
    Multicolour
    Bargraph
    TAG unit
    Colour change in case of failure

  • Interface

    Not defined

  • Dimensions (WxHxD)

    45 x 115 x 118 mm (1.77″ x 4.53″ x 4.65″)

  • Measuring principle

    Process transmitter

  • Function

    Universal process and temperature transmitter with control unit

  • Certification

    ATEX
    FM
    NEPSI
    CSA
    CSA GP
    UR C/US
    Marine approval
    KTA
    German WHG overfill protection

  • Input

    2 x universal (current, voltage, R, RTD, TC, resistance)

  • Output

    2 x Analog (current, voltage)

  • Relay output

    2 x relay
    1 x open collector

  • Auxiliary power supply / Loop power supply

    24 V intrinsically safe loop power supply

  • Dimensions (wxhxd)

    45 x 115 x 118 mm
    (1.77″ x 4.53″ x 4.65″)

  • Software

    Internal software for calculations, linearization, limit monitoring
    Monitoring of sensor wires according NAMUR NE43
    Application package differential pressure measurement

  • Operation

    On site via 3 buttons
    PC configuration via FieldCare

  • Display

    LCD
    7 segment
    Multicolour
    Bargraph
    TAG unit
    Colour change in case of failure

  • Operating Voltage

    20-250V AC/DC wide range power supply

  • Number of poles

    .

Field of application
Analog measured values are indicated, evaluated and calculated by the process transmitter. With the integrated loop power supply two-wire sensors can be powered. The universal inputs enable the connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Via analog outputs process signals can be forwarded. The integrated application package “differential pressure” allows the quick and easy commissioning for differential pressure applications.

The RMA42 process transmitter exhibits a display, analog inputs for process and status signals, analog and digital outputs, and an interface for configuration. Connected sensors can be powered by the integrated LPS. All measured and calculated values are available as a signal source for display, outputs, relays and the interface.Plant and apparatus engineeringControl rooms and cabinetsProcess control, recording and supervisionSignal adjustment and conversionOverfill protection (WHG)

Benefits
SIL 2 approval (optional);
Marine approval1 or 2 calculated values and linearization tableMin./max. value saved5-digit 7-segment LC display, backlit1 or 2 universal inputs2 relays (optional)Digital status output (Open Collector)

RIA15 Loop-powered indicator for 4 to 20 mA or HART signals

For the indication of the 4 to 20 mA signal or the HART® values in the field or in the panel!

  • Measuring principle

    Loop powered indicators

  • Measuring principle

    Loop-powered field indicator

  • Function

    Display

  • Display

    LCD 17 mm (0.67″)
    5-digit
    7-segment bargraph
    Plain text display for unit/TAG
    Activatable backlight

  • Power Supply

    Loop powered

  • Input

    1 x analogue 4…20 mA/HART®

  • Output

    Not defined

  • Output

    Not defined

  • Software functions

    Not defined

  • Certificates

    ATEX II2(1)G Ex ib [ia Ga] IIC T6 Gb
    CSA C/US IS CI.I Div.1 Gr.A-D CSA C/US NI CI.I Div.2 Gr.A-D
    CSA Ex ia, CI. I, Div. 1, Gr. ABCD
    FM IS, CI. I, Div. 1, Gr. ABCD
    EAC 1Ex ib IIC T6 Gb
    IECEx Ex ib [ia Ga] IIC T6 Gb
    JPN Ex ib IIC Gb
    NEPSI Ex ib IIC Gb
    UK II2(1)G Ex ib [ia Ga] IIC T6 Gb
    ATEX IECEx II2(1)G Ex ib [ia Ga] IIC T6
    marine certificate
    UL C/US

  • SIL

    Not defined

  • Panel mounting

    field
    panel mounting

Field of application
The process indicator is available with 4 to 20 mA or with HART® protocol. In the HART® version up to 4 measured values of one sensor can be indicated in alternation. For this the indicator can be set as primary or secondary HART® master and actively inquire the values from the sensor. The small voltage drop of < 1V (< 1.9 V with HART®) is a huge advantage especially in Ex-applications, where in most cases only a reduced voltage is available.

Display of 4 to 20 mA measured values or HART® process variables in all industriesPanel-mount housing or field housing as local displayScalable display valueWith the “Level” or “Analysis” options, basic settings can be made on selected sensors and available measured values and units can be preset quickly and easily.

Benefits
Display of 4 to 20 mA measured values or optionally up to four of a sensor’s HART® process variables in all industries; Use as primary or secondary HART® master5-digit measured value display with 17 mm (0.67″) character height with dimension and bargraph; backlight can be activated Panel-mount housing (IP65) or field housing (IP66; Ex approval) as local display; Minimal installation depthNo external power supply required; Voltage drop ≤1 V (HART® ≤1.9 V) Easy 3-key operation for configuring the deviceInternational approvals; marine approvalSIL interference freeness acc. to EN 60508

EngyCal RH33 BTU meter

Custody transfer BTU meter for recording heat quantities of water

  • Measuring principle

    Energy manager

  • Measuring principle

    Energy manager

  • Function

    Monitoring and billing of energy in heating and cooling applications as well as combined heating-and cooling circles.
    Typical applications can be found in industries, district heating and building automation.

  • Calculations

    heat quantity and heat quantity difference

  • Number of applications

    1

  • Data storage

    yes

  • Calculation standards

    IAPWS-97

  • Communication

    web server
    USB
    Ethernet
    Modbus RTU/TCP Slave
    M-Bus

  • Power supply

    Not defined

  • Loop power supply

    Low voltage power supply:
    100 bis 230 V AC (-15% / +10%)
    Small voltage power supply:
    24 V DC (-50% / +75%)
    24 V AC (±50%)

  • Protection class

    IP65

  • Input

    1x Puls/Analog
    2x RTD/Analog
    Loop power supply 24V DC (+/-16%)

  • Output

    1x 4…20mA
    2x digital (Open Collector)

  • Dimensions (WxHxD)

    144 x 144 x 103.1 mm (5.67″ x 5.67″ x 4.06″)

  • Operation

    3 button on site or via FieldCare
    read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface)
    selectable language

  • Display

    160 x 80 Dot-Matrix LCD with white backlit
    colour change in case of alarm event
    active display area 70 x 34 mm

  • Software functions

    Calculated Values:
    Energy, volume, density, enthalpy & enthalpy difference, DP-Flow-Compensation, mass, temperature difference
    Counters:
    Volume, mass, energy, counter in case of failure
    Optional:
    tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy

  • Certificates

    CE
    CSA GP
    MID 004 (custody transfer) according EN1434 (water/other liquids)
    OIML R75

  • Measuring principle

    Energy manager

  • Function

    Monitoring and billing of energy in heating and cooling applications as well as combined heating-and cooling circles.
    Typical applications can be found in industries, district heating and building automation.

  • Certification

    CE, UL listed, CSA GP, MID 004 (custody transfer) according EN1434 (water/other liquids) and OIML R75

  • Input

    1x Puls/Analog,
    2x RTD/Analog,
    Loop power supply 24V DC (+/-16%)

  • Output

    1x 4…20mA,
    2x digital (Open Collector)

  • Relay output

    2x

  • Auxiliary power supply

    Low voltage power supply: 100 bis 230 V AC (-15% / +10%); Small voltage power supply: 24 V DC (-50% / +75%), 24 V AC (±50%)

  • Dimensions (wxhxd)

    144 x 144 x 103.1 mm
    (5.67″ x 5.67″ x 4.06″)

  • Software

    Calculated Values:
    Energy, volume, density, enthalpy & enthalpy difference,
    DP-Flow-Compensation,
    mass,
    temperature difference;
    Counters: volume, mass, energy, counter in case of failure
    Optional: tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy

  • Operation

    3 button on site or via FieldCare; read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface), selectable language

  • Display

    160 x 80 Dot-Matrix LCD with white backlit, colour change in case of alarm event, active display area 70 x 34 mm

  • Others

    electronic temperature sensor matching via CvD coefficients, logbook measured values, custody transfer logbook, event logbook, limit monitoring

  • Calculations

    IAPWS-IF97

Field of application
The BTU meter RH33 is used in applications with liquid energy carriers.It calculates the thermal energy of water acc. to EN1434, glycol/water mixtures or other fluids such as thermal oils. Temperature sensor matching using calibrated temperature sensors is done in the device. Potential for cost savings can be shown by using the software available as an accessory.The device has a custody transfer approval and allows bi-directional measurement, e.g. charging/discharging of a heat accumulator.

Recording and billing the quantities of heat and cold in:Heating circuitsCooling circuitsCombined heating and cooling circuitsTypical application areas in industry, long-distance heat networks and building automation.

Benefits
Transparent energy consumption helps you save on energy costsCalibrated, electronically paired temperature sensors ensure the highest accuracy and enable replacement of individual temperature sensors even for certified devices in the field (without reapproval!)Tariff counter for requirements-based billingDetailed data logging of current and counter values and of error messages, off-limit conditions and changes to operating parametersStandard models are suitable for connecting and supplying all common volume flow transmitters and temperature measuring pointsRemote readout via Ethernet and

Cerabar PMP71B – pressure transmitter

Smart pressure transmitter – its health can be verified without process interruption

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic

    Pressure transmitter with metallic process diaphragm.
    Available with diaphragm seals.
    Device health verification without process interruptions.
    Intuitive and clear wizards for commissioning, proof tests and verification.

  • Supply voltage

    4…20 mA HART
    Ex d, Ex e, non-Ex:
    10.5…35V DC :
    Ex i: 10.5…30V DC

  • Reference Accuracy

    Standard:
    up to 0.05 %
    Platinum:
    up to 0.025 %

  • Long term stability

    0.05 % of URL/ year
    0.07 % of URL/ 5 years
    0.10 % of URL/ 10 years

  • Process temperature

    Standard:
    -40°C…+125°C
    (-40°F…+257°F)
    Diaphragm seal:
    -70°C…+400°C
    (-94°F…+752°F)

  • Ambient temperature

    -60°C…+80°C
    (-76°F…+185°F)

  • Measuring cell

    400 mbar…700 bar
    (6 psi…10,500 psi)

  • Smallest calibratable span

    5 mbar (0.075 psi)

  • Vacuum resistance

    5 mbar (0.725 psi)

  • Max. Turn down

    100:1

  • Max. overpressure limit

    2,800 bar (40,600 psi)

  • Process connection

    Thread:
    G1/2…G2, R1/2, MNPT3/4…MNPT2,
    FNPT1/2, R1/2
    Flange:
    DN25…DN100,
    NPS 1″…4″
    Pancake: 2″…4″, DN50…DN100

  • Material process membrane

    316L, AlloyC,
    Tantal, Monel,
    PTFE,
    Gold

  • Material gasket

    PTFE

  • Fill fluid

Deltabar PMD75B – differential pressure transmitter

Smart pressure transmitter which detects process anomalies like plugged impulse lines

  • Measuring principle

    Differential pressure

  • Characteristic

    Differential pressure transmitter which detects process anomalies like plugged impulse lines.
    Intuitive and clear wizards for commissioning, proof tests and verification.

  • Supply voltage

    Ex d, Ex e, non-Ex:
    10.5…35V DC
    Ex i: 10.5…30V DC

  • Reference Accuracy

    Standard:
    up to 0.05 %
    Platinum:
    up to 0.035 %

  • Long term stability

    0.025 % of URL/ year
    0.05 % of URL/ 5 years
    0.10 % of URL/ 10 years

  • Process temperature

    -40°C…+110°C
    (-40°F…+230°F)

  • Ambient temperature

    -40°C…+85°C
    (-40°F…+185°F)

  • Measuring cell

    10 mbar…250 bar
    (0.15 psi…3750 psi)

  • Smallest calibratable span

    0.25 mbar (0.00375 psi)

  • Vacuum resistance

    25 mbar (0.0375 psi)

  • Max. Turn down

    100:1

  • Max. overpressure limit

    1600 bar (23,200 psi)

  • Process connection

    NPT1/4-18
    RC1/4″

  • Material process membrane

    316L, AlloyC,
    Tantal,
    Monel,
    Gold

  • Material gasket

    PTFE, FKM, EPDM, FFKM

  • Fill fluid

    Silicone oil,
    Inert oil

  • Material housing

    Aluminium, 316L

  • Communication

    4…20 mA HART
    PROFINET with Ethernet-APL
    Bluetooth® wireless
    technology and app (optional)

  • Certificates / Approvals

    ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1,
    NACE MR0103,
    NACE MR0175

  • Drinking water approvals

    NSF, KTW

  • Specialities

    Heartbeat Technology,
    Bluetooth® Operation and maintenance SmartBlue App,
    LED Module,
    RFID TAG for easy identification,
    Plug and play functionalities,
    HistoROM

  • Measuring principle

    Differential pressure

  • Characteristic / Application

    Differential pressure transmitter which detects process anomalies like plugged impulse lines.
    Intuitive and clear wizards for commissioning, proof tests and verification.

  • Specialities

    Heartbeat Technology,
    Bluetooth® Operation and maintenance with SmartBlue App,
    LED Module,
    RFID TAG for easy identification,
    Plug and play functionalities
    HistoROM

  • Supply / Communication

    Ex d, Ex e, non-Ex:
    10.5…35V DC
    Ex i:
    10.5…30V DC

  • Accuracy

    Standard:
    up to 0.05 %
    Platinum:
    up to 0.035 %

  • Long term stability

    0.025 % of URL/ year
    0.05 % of URL/ 5 years
    0.10 % of URL/ 10 years

  • Ambient temperature

    -54°C…+85°C
    (-65°F…+185°F)

  • Process temperature

    -40°C…+110°C
    (-40°F…+230°F)

Raman Rxn2 analyzer

Bridge your application from the laboratory to the process environment

  • Measuring principle

    Raman spectroscopy

  • Spectral coverage

    Starter:
    300-3300 cm-1 (785 nm)
    Base Model:
    150-4350 cm-1 (532 nm)
    150-3425 cm-1 (785 nm)
    200-2400 cm-1 (1000 nm)
    Hybrid: 175-1890 cm-1 (785 nm)

  • Spectral resolution

    Starter:
    10 cm-1 (average)
    Base model (average):
    5 cm-1 (532 nm)
    4 cm-1 (785 nm)
    5 cm-1 (1000 nm)
    Hybrid:
    4 cm-1 (785 nm) average

  • Channels

    Starter:
    Single channel
    Base Model:
    Up to four channels
    Hybrid:
    Up to two channels

  • Temperature

    Operating:
    15 to 30 °C
    59 to 86 °F
    Storage:
    -15 to 50 °C
    5 to 122 °F

  • Relative humidity

    20 to 80 %, non-condensing

  • Input voltage

    100-240 V, 50-60 Hz, ±10%

  • Power consumption (W)

    400 (max)
    250 (typical start-up)
    120 (typical running)

  • Warm up time (minutes)

    120

  • Unit dimensions (width x height x depth)

    Benchtop model:
    279 x 483 x 592 mm
    10.99 x 19.02 x 23.31 inch
    Cart model:
    685 x 1022 (to tabletop) x 753 mm
    26.97 x 40.24 (to tabletop) x 29.65 inch

  • Weight

    Base model:
    32 kg / 71 lbs
    Cart model:
    93 kg / 205 lbs

  • Sampling probe compatibility

    Starter:
    Raman Rxn-10 (with accessory optics)
    Base model:
    Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46
    Hybrid:
    Channel 1 – Raman Rxn-20 (with accessory optics)
    Channel 2 – Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46

  • Automation interface

    OPC
    Modbus
    HTTPS
    (contact us for other options)

  • Installation options

    Benchtop (standard) or mobile wheeled cart

  • Hazardous area certifications

    ATEX, CSA, IECEx

  • Measuring principle

    Raman spectroscopy

  • Spectral coverage

    Starter:
    300-3300 cm-1 (785 nm)
    Base Model:
    150-4350 cm-1 (532 nm)
    150-3425 cm-1 (785 nm)
    200-2400 cm-1 (1000 nm)
    Hybrid: 175-1890 cm-1 (785 nm)

  • Spectral resolution

    Starter:
    10 cm-1 (average)
    Base model (average):
    5 cm-1 (532 nm)
    4 cm-1 (785 nm)
    5 cm-1 (1000 nm)
    Hybrid:
    4 cm-1 (785 nm) average

  • Channels

    Starter:
    Single channel
    Base Model:
    Up to four channels
    Hybrid:
    Up to two channels

  • Temperature

Raman flow assembly

Precise composition measurement of high-speed, low volume samples for downstream optimization

  • Measuring principle

    Raman Spectroscopy

  • Temperature

    Micro flow bench:
    Operating:
    0 to 40 °C / 32 to 104 °F
    Storage:
    -10 to 50 °C / 14 to 122 °F
    Micro flow cell:
    Operating:
    0 to 40 °C / 32 to 104 °F
    Storage:
    -20 to 60 °C / -4 to 140 °F

  • Relative humidity

    Micro flow cell:
    Storage:
    < 90 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Micro flow bench:
    254 x 102 x 66 mm
    10.0 x 4.0 x 2.6 inch
    Micro flow cell:
    46 x 25 x 11 mm
    1.8 x 1.0 x 0.4 inch

  • Sampling probe compatibility

    Raman Rxn-10 in tandem

  • Sample interface

    Micro flow bench:
    Micro flow cell

  • Pressure

    Micro flow cell:
    Max pressure: 4.8 barg / 70 psig

  • Wetted materials

    Micro flow cell:
    Body: 316L stainless steel
    Window: Proprietary material, optimized for bioprocesses
    Surface finish: Ra 15 with Electropolish to ASME BPE SF4 finish
    Adhesive: USP Class VI and ISO 10993 compatible

  • Sterilization method

    Micro flow cell:
    CIP/SIP

  • Process connection

    Micro flow cell:
    5/16-24 flat bottom ferrules
    Up to 3/16 inch OD tubing

  • Fluid Path Thickness

    Micro flow bench:
    1.0 to 5.0 mm (flow cell driven)
    Micro flow cell:
    2.5 mm

  • Flow Conditions (Flowcell)

    Micro flow cell:
    Laminar

  • Flow Cell Maximum Volumetric Flowrate (mL/min)

    Micro flow cell:
    15

  • Amplification Available or Amplification Factor?

    Micro flow bench:
    Yes
    > 3.0 (TYP)
    > 2.5 (MIN)

Field of application
The Raman flow assembly brings in-line Raman spectroscopy to downstream bioprocessing. Comprised of a flow cell and associated flow bench connected to an Rxn-10 probe, this system meets the speed demands of downstream by optimizing Raman collection for low-turbidity, low volume samples. Ideally suited for development-scale flow rates, the Raman flow assembly provides real-time monitoring, rapid process optimization, and process control for chromatography and other downstream unit operations.

Downstream: aggregation, protein crystallization, formula stability, product CQA, protein concentration, buffer excipients Midstream: analyte monitoring in permeate

Benefits
Brings Raman-based process insights and control to downstream bioprocessing unit operations Achieves lower limits of detection through enhancement of the Raman signal  Provides continuous, real-time measurements with high sensitivity for development-scale flow rates  Easily connects to an Rxn-10 probe paired with a Raman Rxn embedded analyzer, and ensures transferability when used with the Raman flow assembly calibration and verification kitWith the flow bench, provides flexibility to swap out flow cells any time without impacting your process or sterility

Raman bio multi optic and bio sleeve

Maintain sterility and spectral quality while reducing maintenance and cleaning burdens

  • Measuring principle

    Raman spectroscopy

  • Temperature

    -30 to 150 °C / -22 to 302 °F

  • Sampling probe compatibility

    Raman Rxn-10

  • Pressure

    Bio Sleeve:
    Max pressure: 13.8 barg / 200 psig

  • Wetted materials

    Bio sleeve:
    Body: 316L stainless steel
    Window: Proprietary material, optimized for bioprocesses
    Surface finish: Ra 15 with Electropolish to ASME BPE SF4 finish
    Adhesive: USP Class VI and ISO 10993 compatible

  • Length

    120 or 220 mm

  • Diameter

    Bio sleeve:
    12 mm

  • Sterilization method

    Bio sleeve:
    Autoclave, gamma irradiation

  • Process connection

    Bio Sleeve:
    PG13.5

Field of application
The bio multi optic and bio sleeve duo delivers reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectra quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactor setups.

Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more Use with flow assembly CYA680 for select downstream bioprocessing applications

Benefits
Patented self-focusing lens with automatic alignment for optimal spectral quality and reproducibility Improved ease of use with less probe service and maintenance Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time Autoclavable, gamma sterilizable, and compatible with standard cleaning protocols (bio sleeve), with reduced risk of cross-contamination (via non-contact multi optic) 120 mm version is compatible with Endress+Hauser flow assembly CYA680

Raman non-contact optics

Protect your samples with contact-free measurement

  • Measuring principle

    Raman spectroscopy

  • Sampling probe compatibility

    Raman Rxn-10 probe

  • Sample interface

    Temperature: ambient

  • Pressure

    Ambient

  • Length

    Varies based on model

  • Diameter

    Varies based on model

  • Working distance

    NCO-0.4-NIR: 10 mm / 0.40 inch
    NCO-0.5-VIS: 12.5 mm / 0.50 inch
    NCO-1.3-VIS: 33 mm / 1.30 inch
    NCO-2.5-VIS: 64 mm / 2.52 inch
    NCO-3.0-NIR: 75 mm / 2.96 inch
    NCO-5.5-VIS/NIR: 140 mm / 5.52 inch

Field of application
Paired with the Rxn-10 probehead, Raman non-contact optics provide contact-free Raman measurements of samples either directly or through sight glass or translucent packaging. Available with a range of working distances, these highly versatile optics are the perfect choice for use with solids or turbid media. They are also well suited for delicate or corrosive samples when sample contamination or damage to optical components is a concern.

Pharmaceutical: Drug product manufacturingChemical: Polymer solids (pellets, films, or powders)Food & Beverage: Meat or fish qualityRaw material identificationFormulation optimization

Benefits
Range of working distances for remote measurements either directly or through sight glass and translucent packagingHighly versatile – measuring films to pellets to powdersAccurate measurement of static or moving samplesContact-free analysis of delicate or corrosive samples

Raman bIO-Optics

Continuous, inline, multi-component bioprocess measurement

  • Measuring principle

    Raman spectroscopy

  • Sampling probe compatibility

    Raman Rxn-10 probe

  • Sample interface

    Temperature: –30 to 150 °C / -22 to 302 °F

  • Pressure

    Max pressure: 13.8 barg / 200 psig

  • Wetted materials

    Body: 316L stainless steel
    Window: Proprietary material, optimized for bioprocesses
    Process connection: PG13.5
    Surface finish: Ra 15 with electropolish
    Adhesive: USP Class VI and ISO 10993 compatible

  • Length

    120, 220, 320, or 420 mm
    4.73, 8.67, 12.60, 16.54 inch

  • Diameter

    12 mm / 0.48 inch

  • Sterilization method

    Autoclave

  • Process connection

    PG13.5

Field of application
Raman bIO-Optics are versatile immersion optics used in conjunction with the Rxn-10 probehead and compatible with standard bioreactor ports. The fixed focus design provides long-term measurement stability along with superior signal performance, essential for transferable, high performance Raman-based bioprocess analysis. Available in industry standard lengths, Raman bIO-Optics are ideally suited for both glass and plastic benchtop bioreactor/fermenter applications requiring headplate entry.

Cell culture: glucose, lactate, glutamine, amino acids, cell density, titerFermentation: glycerol, methanol, ethanol, sorbitol, biomassDownstream: aggregation, protein crystallization, formula stability, product CQA, protein concentration, buffer excipients

Benefits
Immersion optics for multi-component bioprocess measurementCompatible with standard bioreactor portsFixed-focus designAvailable in 12 mm diameter with Pg 13.5 threaded connector120, 220, 320, or 420 mm lengthsAutoclavable

Raman immersion optic

Unlock the power of in situ laboratory analysis of liquids, slurries, and semi-solids

  • Measuring principle

    Raman spectroscopy

  • Sampling probe compatibility

    Raman Rxn-10 probe

  • Sample interface

    Temperature range:
    -30 to 120 °C / -22 to 248 °F (316L stainless steel)
    -30 to 280 °C / -22 to 536 °F (C276 alloy)
    -30 to 300 °C / -22 to 572 °F (Grade 2 Titanium)

  • Pressure

    Min pressure:
    Full vacuum (0 bara) but not ultrahigh vacuum (UHV) where outgassing maybe a concern
    Max pressure 1/4 inch IO:
    68.5 barg/ 993 psig (316L stainless steel)
    74 barg/ 1073 psig (C276 alloy)
    29 barg/ 420 psig (Grade 2 titanium)
    Max pressure 1/2 inch IO:
    68.5 barg/ 993 psig (316L stainless steel)
    74 barg/ 1073 psig (C276 alloy)
    29 barg/ 420 psig (Grade 2 titanium)

  • Wetted materials

    Metal: C276 alloy as standard (316L stainless steel or Grade 2 titanium upon request)
    Window: high-purity sapphire, proprietary compression fit non-brazed design

  • Length

    Immersion Optic shaft length:
    152, 305, or 457 mm
    6, 12, or 18 inch
    Outer diameter: 12.7 mm / 0.5 inch
    Immersion Optic shaft length:
    152 or 203 mm
    6 or 8 inch
    Outer diameter: 6.35 mm / 0.25 inch

  • Working distance

    Short (S): 0 mm / 0 inch
    Long (L): 3 mm / 0.12 inch

  • Operating range

    VIS or NIR

Field of application
The fixed focus design of the Raman immersion optic provides long-term measurement stability along with superior signal performance which is essential for transferable, high-performance Raman measurements. Compatible with the Rxn-10 probehead, the immersion optic uses no movable parts so it is always in focus. The Raman immersion optic is well-suited for use in reaction vessels, laboratory reactors, or process streams, and its wettable components resist corrosion in harsh environments.

Pharmaceutical: drug substance unit operations, reaction analysis, crystallization, end-point detection, solvent swapsChemical: material identification, reaction analysis, polymerization, cross-linking, blendingFood & Beverage: blending, purification, natural and synthetic componentsDevelopment laboratory

Benefits
Ideal for quick liquids, slurries & semi-solids measurements in the labSuperior signal performanceAvailable in 1/4” and 1/2” diametersNo user-adjustable partsWettable components resist corrosion in harsh environments (including acidic solutions)

Raman electro-optical (EO) fiber optic cables

Innovative Raman fiber optics designed for maximum laser safety and easy installation

  • Measuring principle

    Raman spectroscopy

  • Temperature

    Range:
    -40 to 70 °C / -40 to 158 °F

  • Fiber optic cable

    Length: 5000 mm / 196.86 inch (custom lengths available)
    Bend radius: 152.4 mm / 6 inch

Field of application
Our Raman embedded analyzers and probes are connected by electro-optical (EO) fiber optic cables with integrated low-voltage electrical interlock and optical fiber cable components bundled into one CSA-rated assembly. Rated for indoor/outdoor use, the EO connector is designed to protect the connection from external influences, avoid breakage, and ensure a secure connection. EO fiber cables are available in several size lengths with extension cables to simplify installation and remote analysis.

Used in all Raman Rxn embedded analyzer installationsSupports remote analysis of both lab and process measurementsUsed in a variety of industries: Life Sciences, Chemical, Oil & Gas, Food and Beverage

Benefits
Simple plug and lock designIntegrated safety interlock to prevent laser exposureCertified for hazardous area environmentsIndoor/outdoor rated cable – flame retardant, fungus resistant, internal strength memberAvailable in different fiber lengths to meet your installation requirements

JT33 TDLAS gas analyzer

Reliable H2S measurement for increased quality, process control, and asset integrity

  • Measuring principle

    TDLAS

  • Channels

    1

  • Analyte and measurement ranges

    H2S (Hydrogen sulfide):
    0 to 10 ppmv
    0 to 500 ppmv
    other ranges by request

  • Measured variables

    Concentration
    Cell pressure
    Cell temperature

  • Ambient temperature range

    JT33 TDLAS gas analyzer system:
    –20 to 50 °C (–4 to 122 °F)
    –10 to 60 °C (14 to 140 °F)

  • Operating pressure range

    Application dependent
    800 to 1200 mbara (standard)
    800 to 1700 mbara (optional)

  • Analyzer wetted materials

    316L stainless steel
    FKM O-Rings
    Glass
    PCTFE/PTFE

  • Power supply

    For controller (spectrometer):
    AC 100 to 240 V tolerance ±10 %, 50/60 Hz, 10W
    DC 24 V tolerance ±20 %, 10W
    UM = AC 250 V
    For sample conditioning system electronics:
    AC 100 to 240 V ±10 %, 50/60 Hz, 275W
    UM = AC 250 V

  • Communication

    I/O1: Modbus RTU/RS485 or Modbus TCP/Ethernet
    I/O2 and 3: Relay output or Universal I/O (UIO); UIO can be configured as analog input/output (4-20 mA) or digital/status output
    Service web server interface: Ethernet RJ45

  • Housing materials

    Electronics: Coated copper-free aluminum or Cast stainless steel
    Sample system enclosure: 304 stainless steel or 316 stainless steel
    Sample system panel: Anodized aluminum
    Enclosure window (optional): Polycarbonate

  • Hazardous area approvals

    ATEX/IECEx/UKEx Zone 1
    CSA Class I, Division 1
    CSA Class I, Zone 1

  • Degree of protection

    IP66, Type 4X

  • Product safety

    CE
    RCM
    FCC
    CRN

J22 TDLAS gas analyzer

Proven technology for accurate and reliable measurement of H2O in natural gas

  • Measuring principle

    TDLAS

  • Product Headline

    Best-in-class gas analyzer for moisture (H2O) that is exceptionally reliable and tailored for the natural gas industry. The sensor measures gas using a tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream. Heartbeat Technology ensures compliance and process safety at all times.

  • Channels

    1

  • Analyte and Measurement ranges

    H2O (Moisture):
    0 to 50 ppmv (minimum)
    0 to 6000 ppmv (maximum)

  • Measured Variables

    Concentration
    Dew Point
    Cell Pressure
    Cell Temperature

  • Ambient Temperature range

    -20 to 60°C (-4 to 140°F)

  • Operating Pressure range

    Inlet Pressure: 140 to 310 kPa (20 to 45 psig)
    Sample Cell: 800 to 1200 mbara or 800 to 1700 mbara (optional)

  • Analyzer Wetted materials

    316L stainless steel
    FKM O-Rings
    Glass

  • Power supply

    Without heater: 24 VDC ±20% or 100 to 240 VAC ±10%, 50/60 Hz, 10W
    With optional heater: 100 to 240 VAC ±10%, 50/60 Hz, 80W

  • Communication

    Service webserver interface: Ethernet RJ45
    I/O1: Modbus RS485 or Modbus TCP
    I/O2 and 3: Relay output or Universal I/O (UIO); UIO can be configured as analog input/output (4-20 mA) or digital/status output

  • Housing materials

    Electronics: Copper-free aluminum
    Sample System Enclosure: 304 stainless steel or 316 stainless steel
    Sample System Panel: Anodized aluminum

  • Hazardous area approvals

    ATEX / IECEx /UKEx Zone 1
    PESO / KTL / CML Zone 1
    INMETRO Zone 1
    CSA Class I, Division 1
    CSA Class I, Zone 1

  • Degree of protection

    IP66, Type 4X

  • Product safety

    CE
    RCM
    FCC
    CRN

Field of application
The J22 gas analyzer uses patented tunable diode laser absorption spectroscopy (TDLAS) technology to provide accurate measurement of H2O in natural gas. Featuring the reliable diagnostic capabilities of Heartbeat Technology, the J22 analyzer determines the concentration of a gas without coming into physical contact with streams. It allows pipeline operators and suppliers to meet quality specifications, prevent pipeline corrosion, and stop hydrate formation to ensure safety and asset integrity.

For use in natural gas for quality measurements in production, storage, transportation, and distribution Monitoring and control in the natural gas pipeline, processing plant, compressor station, gathering site, and distributionIdeal for custody transfer measurements to ensure gas quality Measuring at the inlet and outlet of the dehydration process to ensure dry gas product quality in H2 production and CCUS applications Measurable ranges of up to 0-6000 ppm (0-284 lb/mmscf) H2O

Benefits
Ensures highest availability for production, transmission, storage and distribution of natural gasUser-friendly interface with intuitive menu and web server software Integrated diagnostic and verification with Heartbeat Technology Automatically-stored historical data and spectrum logging NIST-traceable calibration providing superior accuracy and repeatabilityRobust design for easy installation, commissioning, and repairField serviceable components and modules for minimal downtime

Commubox FXA195 USB/HART modem

World’s only intrinsically safe HART/USB interface for Device & FieldCare and FieldXpert software

  • Measuring principle

    Communication Interface

  • Function

    Connects intrinsically safe Smart transmitters with HART protocol to the USB port of a personal computer or laptop. This makes the remote operation of the transmitters possible with FieldCare.

  • Input

    USB signal as per USB specification.

  • Output

    Connects HART field devices with the USB interface of a laptop

  • Certificates

    ATEX
    FM
    CSA

Field of application
The Commubox FXA195 modem connects HART logged, intrinsically safe measuring devices to the USB interface of a Windows system.

This makes the remote operation of the transmitters possible with the aid of the Endress+Hauser FieldCare software. Power is supplied to the Commubox by means of the USB interface.

Benefits
Remote commissioning of field devices directly from the control room or anywhere in the current loopFull support for FieldCare softwareFor connection to intrinsically safe circuits (4…20 mA)Reactionless in accordance with IEC 61508 for connection to 4…20 mA SIL 2 loopsSwitchable communication resistorAdapter cable for the FXA195 USB/HART Modem supplied (4mm/2mm)

Liquiphant FTL51B – digital, simple and safe

Point level switch for all liquid media

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Compact vibronic device with an optional pipe extension up to 6 m (19.7 ft);
    Modular housing concept;
    Wide range of certificates

  • Specialities

    Heartbeat Technology,
    Bluetooth® Operation and maintenance SmartBlue App,
    LED Module,
    RFID TAG for easy identification,
    Second line of defense,
    Ambient temperature down to -50°C (-60°C optional),
    Temperature spacer for high process temperature,
    Plug and play functionalities

  • Supply / Communication

    19…253V AC / 2-wire,
    10…55V / DC-PNP 3-wire,
    9…20V DC with relay DPDT,
    19…253V AC or 19…55V DC with relay DPDT,
    2-wire NAMUR,
    2-wire PFM,
    4-20mA HART

  • Ambient temperature

    -60 °C…+70 °C
    (-51 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…100 bar
    Vacuum…1450 psi

  • Min. density of medium

    0.5 g/cm³
    (0.4 g/cm³ optional)

  • Main wetted parts

    316L
    Alloy

  • Process connection

    Threads:
    G3/4A, G1A, R3/4″, R1, NPT3/4, NPT1
    Flanges:
    DN25…DN100
    ASME 1″…4″
    JIS 25A…100A

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Sensor length

    Up to 6 m (19.7 ft)

  • Communication

    2-wire direct load
    HART
    DC-PNP 3-wire
    Relays
    NAMUR
    PFM
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, IEC Ex, CSA, NEPSI, KC, JPN Ex, INMETRO, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL2/ SIL 3 according to IEC 61508

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3 Process Piping
    AD2000
    CRN
    AD 2000

  • Marine approval

    ABS/ LR/ BV/ DNV

  • Options

    Heavy duty stainless steel housing

  • Components

    FTL325P Interface PFM
    FTL325N Interface NAMUR

  • Measuring principle

    Vibration Density

  • Product Headline

    Vibronic point level switch with optional extension tube for liquid applications in hazardous areas .
    Reliable measurement values not affected by: changing media properties, gas bubbles, foam, build-up, flow or turbulences.

Micropilot FMR62B – 80 GHz radar sensor

Smart Safety for your process

  • Measuring principle

    Level radar

  • Characteristic / Application

    Premium device for continuous non-contact
    level measurements, where aggressive media
    are used; For vessels with many internals

  • Specialities

    Heartbeat Technology;
    SIL 2/3 according to IEC 61508;
    Bluetooth® commissioning;
    Operation and maintenance with SmartBlue App;
    HistoROM;
    RFID TAG for easy identification;
    Very narrow beam angle

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA)
    PROFINET with Ethernet-APL
    Bluetooth® wireless technology

  • Frequency

    W-Band (~80 GHz)

  • Accuracy

    +/-1 mm (0.04 in)

  • Ambient temperature

    -40 … +85 °C (-40 … +185 °F)

  • Process temperature

    -196 … +450 °C (-321 … +842 °F)

  • Process pressure / max. overpressure limit

    Vacuum…160 bar (2320 psi)

  • Main wetted parts

    316L or PTFE (clad 316L flanges)

  • Process connection

    Flange:
    DN50 … DN150
    ASME 2″ … 8″

  • Max. measurement distance

    80 m (262 ft)

  • Communication

    HART/ PROFIBUS PA
    PROFINET with Ethernet-APL
    Bluetooth® wireless
    technology and app (optional)

  • Certificates / Approvals

    IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex,
    INMETRO Ex, NEPSI Ex, UK Ex

  • Safety approvals

    Overfill protection WHG;
    SIL 2/ SIL 3

  • Design approvals

    Acceptance test certificate 3.1, EN10204;
    NACE MR0175 / ISO 15156;
    NACE MR0103 / ISO 17945;
    EU Food Contact Material (EC) 1935/2004;
    US Food Contact Material FDA CFR 21;
    Declaration of Conformity ASME B31.3;
    Conformity to cGMP;
    AD2000;
    PMI test;
    CRN approval;
    Helium leak test;
    Liquid penetrant test AD2000-HP5-3(PT);
    Liquid penetrant testing ISO23277-1 (PT);
    Liquid penetrant testing ASME VIII-1 (PT);
    Welding documentation (according to ISO or ASME)

  • Marine approval

    ABS, LR, BV, RINA, DNV

  • Options

    Display,
    Customized settings,
    App ‘SmartBlue’ for commissioning and operation via Bluetooth
    Gas-tight implementation;
    Overvoltage protection;
    PWIS free

  • Application limits

    Strong turbulences and foam,
    long stilling wells (>12 m) and bypass -> FMR5x,FMP5x

Field of application
Micropilot FMR62B is part of the new generation of 80 GHz radar sensors. It is used for continuous non-contact level measurement in challenging liquid applications. It masters process requirements like high temperatures, high process pressure as well as changing media. Testing concepts for SIL-locking and proof tests reduces the risk of systematic errors. Heartbeat Technology offers verification and monitoring functions to identify anomalies for increased safety and productivity.

The Micropilot FMR62B is suitable for free-space applications up to 80m and offers high beam focusing for vessels with many internal fittings. Process connections: FlangesTemperature: –196 to +450 °C (-320 to +842°F)Pressure: –1 bis +160 bar (-14.5 to 2320.6 psi)Maximum measuring range: 80 m (262.5 ft)Accuracy: ±1 mm (0.04 in)W-band: 80 GHzInternational explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5- or 10-point factory calibration certificate

Benefits
Increased productivity thanks to process monitoring, verification, and diagnostics in the running process with Heartbeat Technology Safety by design: Device development according to IEC 61508 for SIL 2 and SIL 3 applications (e.g. in homogeneous redundancy) Reduction of systematic errors through guided SIL-locking, verification and proof testing Easy handling through intuitive operation and wizards, for commissioning and verifications Easier troubleshooting through recommended actions shown on the display

Digital pH sensor Memosens CPS11E

Memosens 2.0 pH electrode for standard applications in process and water & wastewater industries

  • Measuring principle

    Potentiometric

  • Application

    Long-term monitoring and limit control in processes with stable process conditions
    Water and wastewater treatment

  • Characteristic

    Digital pH electrode for standard applications in process and environmental technology with dirt-repellent PTFE ring junction and built-in temperature sensor

  • Measurement range

    Application A
    • pH: 1 to 12
    Application B
    • pH: 0 to 14
    Application F
    • pH: 0 to 10

  • Measuring principle

    Gel compact electrode with PTFE ring junction

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type A, B, F
    Metal lead: Ag/AgCl
    Aperture: Ring-shaped PTFE junction, sterilizable
    O-ring: FKM
    Process coupling: PPS fibre-glass reinforced
    Nameplate: ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.47 inch)
    Shaft length: 120, 225, 360 and 425 mm
    (4.72, 8.86, 14.17 and 16.73 inch)

  • Process temperature

    Application A: –15 to 80 °C (5 to 176 °F)
    Application B: 0 to 135 °C (32 to 275 °F)
    Application F: 0 to 70 °C (32 to 158 °F)

  • Process pressure

    Applications A and B:
    0.8 to 17 bar (11.6 to 246.5 psi) absolute
    Application F:
    0.8 to 7 bar (11.6 to 101.5 psi) absolute

  • Temperature sensor

    NTC 30K

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

  • Additional certifications

    Additional certifications

Field of application
Memosens CPS11E is the digital all-rounder for stable processes. It measures reliably even in extreme pH ranges or hazardous areas. Thanks to Memosens 2.0 digital technology, the pH sensor resists moisture and enables lab calibration, increasing process safety and simplifying operation. Its extended storage of calibration and process data provides the perfect basis for predictive maintenance. Designed for a long operating life and low maintenance, Memosens CPS11E offers you best value for money.

Long-term monitoring and limit monitoring of processes with stable process conditions: – Chemical industry- Pulp & paper industry- Power plants (e.g. flue gas washers, boiler feed water)- Incineration plantsWater & wastewater treatment:- Drinking water- Cooling water- Well water- Wastewater treatment plantsWith ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Benefits
IIoT ready: Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. Low operating costs: Lab calibration and quick sensor exchange in the process result in minimized process downtime and longer sensor lifetime. Robust, low maintenance electrode: Long poison diffusion path or optimized ion trap prevent poisoning of the electrode reference. Large, dirt-repellent PTFE junction protects from soiling by the medium. Process glass is suitable for the full pH range and pressure-stable up to 17 bar (246.5 psi) absolute. Optional F-glass allows application in media containing hydrofluoric acid such as etching baths in semiconductor production. Improved optional salt storage ensures reliable measurement in low conductivity applications such as boiler feed water. Maximum process integrity through non-contact, inductive signal transmission.

Flow assembly Flowfit CPA25

Universal assembly for the water and wastewater industry and industrial auxiliary processes.

  • Measuring principle

    Potentiometric

  • Application

    Water, Wastewater, Utilities

  • Installation

    Flow assembly

  • Characteristic

    Piping, bypass, branch line

  • Design

    ‘- Three PG13.5 sensor ports (shaft length 120 mm)
    – calibration direct in the holder possible with a removable calibration cap

  • Material

    Holder: Polypropylene PP
    Sealing: EPDM or FKM available

  • Process temperature

    0 to 80°C
    (32 to 176°F)

  • Process pressure

    max. 6 bar at 20°C
    (87 psi at 68°F)

  • Measuring principle

    Amperometric oxygen measurement

  • Application

    Water, Wastewater, Utilities

  • Installation

    Flow assembly

  • Characteristic

    Piping, bypass, branch line

  • Design

    ‘- Three PG13.5 sensor ports (shaft length 120 mm)
    – calibration direct in the holder possible with a removable calibration cap

  • Material

    Holder: Polypropylene PP
    Sealing: EPDM or FKM available

  • Process temperature

    0 to 80°C
    (32 to 176°F)

  • Process pressure

    max. 6 bar at 20°C
    (87 psi at 68°F)

  • Measuring principle

    Conductive

  • Application

    Water, Wastewater, Utilities

  • Installation

    Flow assembly

  • Characteristic

    Piping, bypass, branch line

  • Design

    ‘- Three PG13.5 sensor ports (shaft length 120 mm)
    – calibration direct in the holder possible with a removable calibration cap

  • Material

    Holder: Polypropylene PP
    Sealing: EPDM or FKM available

  • Process temperature

    0 to 80°C
    (32 to 176°F)

  • Process pressure

    max. 6 bar at 20°C
    (87 psi at 68°F)

4-channel transmitter Liquiline CM444

Expandable multiparameter field device for all industries

  • Measuring principle

    Potentiometric

  • Application

    Modular 4 wire controller
    Multichannel: 1 to 4 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    4 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors

  • Characteristic

    Robust plastic housing
    All non-ex applications

  • Design

    2 to 4x Memosens input, 2 to 8x current output
    Alarmrelay, 4x relay, SD card for software update and copy & paste of setup

  • Material

    Housing base: PC-FR
    Housing seal: EPDM

  • Dimension

    237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch

  • Process temperature

    -20 to 55 °C (0 to 130 °F)

  • Ingress protection

    IP66 / IP 67

  • Input

    1 to 4x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional

  • Output / communication

    2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet

  • Additional certifications

    EAC, cCSAus

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Modular 4 wire controller
    Multichannel: 1 to 4 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    4 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors

  • Characteristic

    Robust plastic housing
    All non-ex applications

  • Design

    2 to 4x Memosens input, 2 to 8x current output
    Alarmrelay, 4x relay, SD card for software update and copy & paste of setup

  • Material

    Housing base: PC-FR
    Housing seal: EPDM

  • Dimension

    237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch

  • Process temperature

    -20 to 55 °C (0 to 130 °F)

  • Ingress protection

    IP66 / IP 67

  • Input

    1 to 4x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional

  • Output / communication

    2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet

  • Additional certifications

    EAC, cCSAus

  • Measuring principle

    Conductive

  • Application

    Modular 4 wire controller
    Multichannel: 1 to 4 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    4 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors

  • Characteristic

    Robust plastic housing
    All non-ex applications