Surge arrester for DIN rail according to IEC 60715
Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85
Point level switch with extension tube for liquids especially in the food and life sciences industry
Compact vibration point level switch for liquids especially in the food and life sciences industry
For all types of powdered and fine-grained solids especially in the food industry
Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids
Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids
Designed for light bulk solids
Designed for light bulk solids
Transmitterfor non-contact point level detection in bulk solids
Radiation source container with sliding source support rod for manual or pneumatic on/off switching
Reliable and robust level probe with ceramic measuring cell and HART
Simple and reliable level probe for freshwater applications
The standard sensor for highest demands in bulk solids level measurement with 80GHz technology
For 80GHz level measurement in aggressive liquids or applications with hygiene requirements
The standard sensor for highest demands in liquid level measurement with 80GHz technology
Economically efficient basis model for level measurement in solids
Basic model for level liquid applications
For continuous level measurement even in high bulk solids silos or bins
Basic model for continuous level measurement in light bulk solids
For continuous level and interface measurement in liquids - for large measuring ranges
For continuous level measurement in conductive liquids
Effective suppression of background radiation and extraneous radiation at the Gammapilot FMG50
Holder for in-situ measurement in water, wastewater and utilities
Modular assembly for water, wastewater and utilities
Memosens sensor for suspended solids and turbidity measurement in water, wastewater and utilities
Memosens glass electrode for the chemical and life sciences industries
Ready-to-use gel for validation, calibration, and adjustment of oxygen and disinfection sensors
Memosens toroidal conductivity sensor for hygienic and sterile applications
Toroidal conductivity measuring system for hygienic and sterile applications
Memosens sensor for drinking water, wastewater and process water in all industries
Sensor for drinking water, pool and process water as well as utilities in all industries
Simple assembly for drinking and process water applications

HAW562 Surge arrester

Surge arrester for DIN rail according to IEC 60715

  • Measuring principle

    Surge arrester

  • Function

    Surge arrester for DIN rail mounting
    Compact device for an easy ordering (no separation of mounting module and protection module)
    Flexible integration into the measuring chains of the process industry due to approvals according to ATEX & IEC, SIL2 conformity
    compatibility with the established fieldbusses (HART, FF, PA)
    Innovative grounding concept to avoid low-frequency equalizing currents – direct and indirect shield grounding possible in one device
    Uninterruptible operation of the plant due to an automatic resetting after the discharge process

  • Certification

    SIL2 conformity
    CSA

  • Dimensions (wxhxd)

    HAW562-AAA, HAW562-AAD, HAW562-AAE, HAW562-8DA:
    12 x 90 x 72.5 mm
    (0.47″ x 3.54″ x 2.85″)
    HAW562-AAB, HAW562-AAC:
    18 x 90 x 73 mm
    (0.71″ x 3.54″ x 2.87″)

  • Operating Voltage

    24V/60V/230V/5V/12(80)V/24V

  • Measuring principle

    Surge arrester

  • Measuring principle

    Surge arrester for DIN rail mounting

  • Function

    Surge arresters are applied to protect electronic components of a plant against overvoltage! Due to this investment intensive measuring instruments are protected and the plant availability is increased.

  • Application

    Surge protection for power supply or signal / communication cables

  • SIL

    2

  • Certificates

    ATEX
    IECEx
    CSA

Field of application
The HAW562 surge arrester is used to protect electronic components from being destroyed by overvoltage. It ensures that overvoltage surges which occur in signal cables (e.g. 4 to 20 mA), in communication lines (fieldbuses) and in power lines are safely passed into the ground. The functionality of the transmitter or the electronics component to be protected is not affected.

Surge arresters are used to weaken residual currents from upstream lightning protection steps and to limit system-induced or -generated overvoltage surges.
HAW562 units are primarily used in process automation and in measuring and communication technology within the chemicals, pharmaceuticals, water and wastewater sectors as well as in the food industry.

Benefits
Investment intensive measuring instruments protectedIncreased plant availability as surge arrester is perfectly matched to the electronic components involved in process automation and process measuring technologyApplication in Ex areas – optionally available with SIL2 intrinsically safe approvalsVibration and shock tested according to EN 60068-2Direct and indirect shield grounding

Vibronic Point level detection Nivotester FailSafe FTL825

Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    FailSafe level transmitter point level.
    Top hat rail mounting
    Connection to FTL80/81/85
    Permanent self-monitoring,LIVE-Signal.

  • Specialities

    SIL 3 according to IEC61508.

  • Supply / Communication

    85 – 253 VAC/DC
    20 – 30 VAC/20-60VDC

  • Ambient temperature

    –20 to +60 °C
    (–4 to +140 °F)

  • Communication

    2x SPST safety contact point level
    1x SPST signal contact
    1X SPDT fault contact

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI

  • Safety approvals

    Overfill protection WHG
    Leakage Detection

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

Field of application
The Nivotester FTL825 supplies the Liquiphant FailSafe FTL8x point level switch with direct voltage via a two-wire cable. At the same time, it analyzes the current values (4-20mA discrete) of the Liquiphant and returns a switching signal. The signal inputs of the Nivotester FTL825 are galvanically isolated from the mains and the output and can be ordered Safety-critical systems up to SIL3. For industries where redundant or diverse systems are either not recommended or not possible.

FailSafe point level switch unit for top hat rail mounting.

Ambient temperature: -20 to +60°C (-4 to +140°F)
International explosion protection certificates, overfill prevention WHG

Benefits
Use in safety systems requiring functional safety to SIL3 in accordance withIEC 61508 Ed.2.0 /IEC 61511-1 / ISA 84-1Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button For safety-critical systems up to SIL3 in the chemicals, petrochemicals and oil & gas industriesFor applications where redundant or diverse systems are either not recommended or not possible, the longest possible test cycles are desirable, or proof tests are either not possible or only with great difficulty and expenseIntegrated locking function (self-holding)4 switching outputs (can be analyzed separately): 2 as level safety contacts based on the quiescent current principle for a redundant output signal, 1 x signaling contact (e.g. lamp), 1 x fault-signaling contact as changeover contact

Vibronic Point level detection Liquiphant FTL51H

Point level switch with extension tube for liquids especially in the food and life sciences industry

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Premium device for point level detection
    in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
    Modular & completely welded housing concept,
    Wide range of certificates.

  • Specialities

    Plug and play functionalities,
    Surface finish: mechanical or electro-polished,
    Density/Concentration measurement,
    SIL 2/3 according to IEC 61508

  • Supply / Communication

    PROFIBUS PA,
    19 ..253V AC,
    10…55V DC-PNP,
    19…253V AC or 19…55V DC with relay DPDT,
    8/16mA,
    NAMUR,
    PFM

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…64 bar
    (Vacuum…928 psi)

  • Min. density of medium

    0.5g/cm³
    (0.4g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads (for weld-in adapter):
    G3/4A, G1A,
    Flange:
    DN25…DN100,
    ASME 1″…4″,
    JIS 25A…100A

  • Process connection hygienic

    Tri-Clamp,
    DIN 11851, DIN11864-1
    Ingold,
    Flush mount,
    DRD,
    SMS1145,
    Varivent (Var )

  • Sensor length

    Short tube (Liquiphant II)
    148mm…3000mm (6,00…118″)

  • Communication

    PROFIBUS PA

  • Certificates / Approvals

    ATEX, IEC Ex, FM, CSA C/US, TIIS,
    INMETRO Ex, NEPSI Ex

  • Safety approvals

    Overfill protection WHG,
    SIL 2/ SIL 3

  • Design approvals

    Inspection certificate 3.1, EN10204,
    CoC ASME BPE,
    Conformity to cGMP,
    EU Food Contact Material (EC) 1935/2004,
    US Food Contact Material FDA CFR 21,
    CN Food Contact Material GB 4806,
    Declaration of Conformity ASME B31.3,
    AD2000,
    CRN approval

  • Hygienic approvals

    3-A,
    EHEDG,
    CoC-ASME BPE

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Customized settings (Density)

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

  • Successor

    FTL63

  • Measuring principle

    Vibration Density

  • Characteristic / Application

    Premium device for density measurement in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Sensor with pipe extension up to 3 m (9,85 ft).
    Modular housing or completely welded compact housing.
    Wide range of certificates.

  • Supply / Communication

    via density controller FML621

  • Ambient temperature

    -40 °C…70 °C (-40…158 °F)
    -40 °C…60 °C (-40…140 °F) for hazardous applications

  • Process temperature

    0…80 °C (32…176 °F) – standard temperature range
    -50…0 °C / 80…150 °C (with reduced technical data/accuracy)

  • Process pressure

    0…25 bar (0…362 psi) – standard pressure range
    >25…64 bar (>362…928 psi) – with reduced technical data/accuracy

  • Wetted parts

    316L

  • Hygienic

    3A
    EHEDG

  • Sensor length

    Short tube (Liquiphant II)
    148mm…3000mm (6,00…118″)

  • O

Vibronic Point level detection Liquiphant FTL50H

Compact vibration point level switch for liquids especially in the food and life sciences industry

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Premium device for point level detection
    in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Compact sensor version,
    Modular & completely welded housing concept,
    Wide range of certificates.

  • Specialities

    Plug and play functionalities,
    Surface finish: mechanical or electro-polished,
    Density/Concentration measurement,
    SIL 2/3 according to IEC 61508

  • Supply / Communication

    PROFIBUS PA,
    19 ..253V AC,
    10…55V DC-PNP,
    19…253V AC or 19…55V DC with relay DPDT,
    8/16mA,
    NAMUR,
    PFM

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…64 bar
    (Vacuum…928 psi)

  • Min. density of medium

    0.5g/cm³
    (0.4g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads (for weld-in adapter):
    G3/4A, G1A.
    Flange:
    DN25…DN100
    ASME 1″…4″,
    JIS 25A…100A

  • Process connection hygienic

    Tri-Clamp,
    DIN 11851, DIN11864-1
    Ingold,
    Flush mount,
    DRD,
    SMS1145,
    Varivent (Var )

  • Sensor length

    Compact sensor

  • Communication

    PROFIBUS PA

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    Overfill protection WHG,
    SIL 2/ SIL 3

  • Design approvals

    Inspection certificate 3.1, EN10204,
    CoC ASME BPE,
    Conformity to cGMP,
    EU Food Contact Material (EC) 1935/2004,
    US Food Contact Material FDA CFR 21,
    CN Food Contact Material GB 4806,
    Declaration of Conformity ASME B31.3,
    AD2000,
    CRN approval

  • Hygienic approvals

    3-A,
    EHEDG,
    CoC-ASME BPE

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Customized settings (Density)

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

  • Successor

    FTL63

  • Measuring principle

    Vibration Density

  • Characteristic / Application

    Premium device for density measurement in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Sensor with pipe extension up to 3 m (9,85 ft).
    Modular housing or completely welded compact housing.
    Wide range of certificates.

  • Supply / Communication

    via density controller FML621

  • Ambient temperature

    -40 °C…70 °C (-40…158 °F)
    -40 °C…60 °C (-40…140 °F) for hazardous applications

  • Process temperature

    0…80 °C (32…176 °F) – standard temperature range
    -50…0 °C / 80…150 °C (with reduced technical data/accuracy)

  • Process pressure

    0…25 bar (0…362 psi) – standard pressure range
    >25…64 bar (>362…928 psi) – with reduced technical data/accuracy

  • Wetted parts

Capacitance Point level detection Nivector FTI26

For all types of powdered and fine-grained solids especially in the food industry

  • Measuring principle

    Capacitive Solid

  • Characteristic / Application

    Compact for all types of powdered solids / small-grain bulk
    solids

  • Specialities

    Active build-up compensation

  • Supply / Communication

    12 V…30 VDC

  • Ambient temperature

    -20°C…60°C
    (-4°F…140°F)

  • Process temperature

    -40°C…80°C
    (-40°F…176°F)

  • Main wetted parts

    PC, ECTFE
    “Protector”
    FDA listed material PBT-GF
    (according to 21 CFR 177.1660)

  • Process connection

    G1

  • Communication

    12 V…30 VDC
    IO-Link

  • Safety approvals

    ATEX, CSA C/US, IEC Ex, EAC Ex

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3-A, EHEDG

Field of application
The Nivector FTI26 is a cost-efficient point level switch for solids in the food industry and powder applications in all industries. The capacitance device convinces with the best build-up performance in class and a high sensitivity. All industry compliant certificates are available. In addition, the FTI26 is industry 4.0 ready with IO-Link communication.

For MIN or MAX detection in silos with powdered and fine-grained solids, like plastic granules, grain, sugar, spices, coffee powder, laundry detergent

Process connections: G1″ thread, Tri-Clamp 2″ via adapter
Temperature: -20 to +80°C (-4 to +176°F)
Pressure: -1 to +6bar (-14.5 to +86psi)
International explosion protection certificates (Dust Ex), hygienic certificates

Benefits
Easy installation even in tight conditions or where access is restricted thanks to the compact designFulfillment of all relevant hygienic requirements (3A, EHEDG, FDA, EG1935/2004); cleanable (IP69) IO-Link reduces costs and complexity with an easy configuration of the devices via engineering tools Best build-up performance in class and high sensitivity No individual adjustment to each medium necessaryLED signalization for on-site function check

Point level switch Soliswitch FTE31 Rotary paddle switch

Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids

  • Measuring principle

    Paddle

  • Characteristic / Application

    universally applicable as a full, empty and demand alarm on silos containing solids

  • Specialities

    Hinged paddle for retro-fitting

  • Supply / Communication

    230V 50/60 Hz
    115V 50/60 Hz
    48V 50/60 Hz
    24V 50/60 Hz
    20 to 28 VDC

  • Ambient temperature

    -20 °C … 60 °C (-4 °F … 140 °F)

  • Process temperature

    -20 °C … 80 °C (-4 °F … 170 °F)

  • Process pressure / max. overpressure limit

    0.5 bar to 1.5 bar (7 psi to 22 psi)

  • Min. density of medium

    >= 100 g/l

  • Main wetted parts

    Shaft: 1.4435
    Paddle: 1.4435

  • Process connection

    Threaded boss – thread NPT 1 1/4″ or NPT 1 1/2″

  • Sensor length

    Standard:
    75 mm (3″)
    100 mm (4″)
    200 mm (8″)
    300 mm (12″)
    400 mm (16″)
    500 mm (20″)
    600 mm (24″)

  • Communication

    Relay

  • Certificates / Approvals

    FM DIP Cl.II,III, Div.1 Gr.EFG
    CSA DIP Cl. II,III, Div.1, Gr.EFG

  • Application limits

    max. grain size 50 mm (2″)

Field of application
The economical Soliswitch FTE31 is a paddle switch for point level detection in bulk materials. Its robust polymer housing and compact design makes it an ideal sensor for full, empty and demand alarm in applications with bulk solids. The optimized materials make the unit outstandingly robust and therefore suitable for use in dust explosive areas.

The universal point level switch FTE31 is used as a full, empty and demand alarm on silos containing solids. Its construction and materials make the unit suitable for use in the food industry. The unit is suitable as a level limit switch in dust-explosion-hazardous areas.

Typical applications are level detection in: Cereals, sugar, cacao, animal feeds, washing powders, chalk, dry plaster, cement, granulates, wood chips

Benefits
Reliable and economical paddle switchHighest safety standard for dust-explosion-hazardous areasDiverse instrument designs for use under different application conditionsSlip clutch prevents impact on paddleIngress protection to IP 65 / NEMA 4x / Type 4x for optimum safety in the process

Point level switch Soliswitch FTE30 rotary paddle switch

Simple mechanical mechanism, extremely robust and cost-effective point level switch for bulk solids

  • Measuring principle

    Paddle

  • Characteristic / Application

    universally applicable as a full, empty and demand alarm on silos containing solids

  • Specialities

    Hinged paddle

  • Supply / Communication

    230 VAC 50/60 Hz
    115 VAC 50/60 Hz
    48 VAC 50/60 Hz
    24 VAC 50/60 Hz
    20 bis 28 VDC

  • Ambient temperature

    -20 °C … 60 °C (-4 °F … 140 °F)

  • Process temperature

    -20 °C … 80 °C (-4 °F … 170 °F)

  • Process pressure / max. overpressure limit

    0.5 bar to 1.5 bar (7 psi to 22 psi)

  • Min. density of medium

    >= 100 g/l

  • Main wetted parts

    Shaft: 1.4305
    Paddle: 1.4301

  • Process connection

    G 1 1/2″, PBT
    G 1 1/2″, 1.4305
    Reinforced shaft G 1 1/2″, 1.4305

  • Sensor length

    100 mm (4″)
    200 mm (8″)
    300 mm (12″)
    400 mm (16″)
    500 mm (20″)
    600 mm (24″)
    Rope length of approx 2000 mm (80″), can be shortened

  • Communication

    Micro switch with changeover contact max. 10 A/250 VAC

  • Certificates / Approvals

    No approvals available

  • Options

    Relay

  • Application limits

    max. grain size 50 mm (2″)

Field of application
The economical Soliswitch FTE30 is a paddle switch for point level detection in bulk materials. Its robust polymer housing and compact design makes it an ideal sensor for full, empty and demand alarm in applications with bulk solids. The optimized materials make the unit outstandingly robust and therefore suitable for use in dust explosive areas.

Process connections: G 1½”, PBT; G 1½”, 1.4305; Reinforced shaft G 1½”, 1.4305
Sensor length: Different standard lengths between 100 mm (4″) and 600 mm (24″), additional rope length of 2,000 mm (80″) (can be shortened)
Temperature: -20 to +80 °C (-4 to +170 °F)
Pressure: 0.5 to 1.8 bar (7 to 25 psi)

Benefits
Reliable and economical paddle switchHighest safety standardDiverse instrument designs for use under different application conditionsSlip clutch prevents impact on paddleIngress protection to IP65 for optimum safety in the process

Capacitance Point level detection Minicap FTC262

Designed for light bulk solids

  • Measuring principle

    Capacitive Solid

  • Characteristic / Application

    No calibration on start-up
    Active build-up compensation
    Mechanically robust
    The rope probe can be shortened
    (optimum matching to the measuring point)

  • Specialities

    Rope shortening parts to be supplied by the customer

  • Supply / Communication

    10,8 … 45V DC, DC-PNP 3-wire
    20 … 253V AC, or
    20 … 55V DC, Relay output

  • Ambient temperature

    -40 °C … 80 °C(-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    -1 … 6 bar(-14.5 … 90 psi)

  • Main wetted parts

    PPS = Polyphenylene sulphide
    (glass fibre content approx. 40%)

  • Max. tensile strength

    3000 N

  • Process connection

    R 1 1/2
    NPT 1 1/2

  • Sensor length

    min. 500 mm (20″), max 6000 mm (236″)

  • Communication

    PNP transistor output
    Relay output (potential-free
    change-over contact / SPDT)

  • Certificates / Approvals

    ATEX , FM, CSA, NEPSI, EAC

  • Options

    Aluminium Housing

  • Application limits

    Solids, grain size max. 30 mm (1.2″),
    DK min 1,5
    Flexural strength 1400 N (at probe tip)

Field of application
Minicap FTC262 is a simple and cost-effective rope probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6. Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.
Process connection: Threads
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: -1 to +6bar (-14.5 to +90psi)
Sensor length: 500mm (20″) to 6,000mm (236″)
International explosion protection certificates, overfill prevention WHG

Benefits
Simple mounting and commissioning without calibrationMechanical safety, cost-efficiency and long operating life due to no wearing partsHigh operational safety and reliability due to active build-up compensationOptimized storage by simply shortening the rope probe on site

Capacitance Point level detection Minicap FTC260

Designed for light bulk solids

  • Measuring principle

    Capacitive Solid

  • Characteristic / Application

    Compact rod probe with build-up compensation
    easy start up

  • Specialities

    FDA-listed material

  • Supply / Communication

    10,8 … 45V DC, DC-PNP 3-wire
    20 … 253V AC, or
    20 … 55V DC, Relay output

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 120°C
    (-40 °F … 248 °F)

  • Process pressure / max. overpressure limit

    -1 … 25 bar
    (-14.5 … 360 psi)

  • Main wetted parts

    PPS = Polyphenylene sulphide
    (glass fibre content approx. 40%)

  • Process connection

    R1″
    NPT1″

  • Sensor length

    140 mm (5.51″)

  • Communication

    PNP transistor output
    Relay output (potential-free
    change-over contact / SPDT)

  • Certificates / Approvals

    ATEX, IEC, FM, CSA, NEPSI, EAC

  • Options

    Aluminium Housing

  • Application limits

    Solids, grain size max. 30 mm (1.2″),
    DK min 1,6
    Flexural strength 1400 N (at probe tip)

Field of application
Minicap FTC260 is a simple and cost-effective rod probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6. Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.
Process connection: Threads
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: -1 to +25bar (-14.5 to +360psi)
Sensor length: 140mm (5.51″)
International explosion protection certificates, overfill prevention WHG

Benefits
Simple mounting and commissioning without calibrationMechanical safety, cost-efficiency and long operating life due to no wearing partsHigh operational safety and reliability due to active build-up compensation

Microwave barrier transmitter Soliwave FQR56

Transmitterfor non-contact point level detection in bulk solids

  • Measuring principle

    Microwave barrier

  • Characteristic / Application

    Transmitter
    Non-contact point level detection and flow monitoring
    Detecting, counting and positioning of objects
    Monitoring of material transfer points
    Detection and analysis of deposits and contamination
    Installation:
    Non-contact installation (transmission window) or front-flush installation (contact)

  • Specialities

    Measurement range: max. 100 m

  • Supply / Communication

    85 … 253VAC
    20 … 30 VDC/ 20 … 60 VAC

  • Ambient temperature

    -40 °C…+70 °C
    (-40 °F…+158 °F)

  • Process temperature

    Non-contact installation: any
    Within installation:
    -40 °C…+70 °C (-40 °F…+158 °F)
    With HT-Adapter:
    up to +450 °C (+842 °F)

  • Process pressure / max. overpressure limit

    Non-contact installation: any
    Within installation:
    0.5 bar…6.8 bar (7.2 psi…99 psi) abs.
    With HD-Adapter:
    up to +21 bar (+305 psi) abs.

  • Min. density of medium

    Solid weight: > 10 g/l

  • Main wetted parts

    Non-contact installation:
    no wetted parts
    Within installation:
    316Ti or Aluminium;
    PTFE or Ceramic

  • Process connection

    1-1/2″ R, 1-1/2″ G, 1-1/2″ NPT

  • Process connection hygienic

    Non-contact installation

  • Certificates / Approvals

    ATEX, IEC Ex, CSA C/US

  • Design approvals

    EN10204-3.1

  • Options

    Sight glass
    High temperature adapter
    High pressure adapter
    Installation bracket
    FAR50, FAR51, FAR52, FAR53, FAR54, FAR55

  • Components

    Transceiver: FDR56

  • Application limits

    Solid weight: < 10 g/l

Field of application
The Soliwave FQR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FDR56 receiver.

Typical bulk solids are: Wood chips, wood dust or flour; plaster, cement, ash, paper or cardboard shred, gravel, sand, dried powders in general, bags and boxes.Process connections: ThreadsAmbient temperature: -40 to +70°C (-40 to +158°F)Measuring range: Max. 100m (328ft)International explosion protection certificates

Benefits
Highly reliable measurement due to flush-mounted installation and possible non-contact installation as well as indication of the signal strength on the receiverMechanical robust solution ensures cost savings over the whole life cycle of the product: No wear and tear, process-wetted ceramic sensor diaphragm (optional), long serviceable life, maintenance free Electronics housing can be rotated by 360°, allowing adjustment into optimum position after installationDirect connection of the supply voltage (transmitter and receiver separately or together)Mechanically compatible to FQR50/FDR50 microwave barrier, existing process connections can continue to be used; likewise, accessories such as adapter flanges, installation brackets and sight glasses can continue to be used

Radiometric Level and density Source Container FQG66

Radiation source container with sliding source support rod for manual or pneumatic on/off switching

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    435kg

  • Specialities

    Sliding source support rod for manual or pneumatic on/ off switching

  • Ambient temperature

    -55 °C…+100 °C
    (-67 °F…+212 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    435kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -55 °C…+100 °C
    (-67 °F…+212 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    Approximately 435 kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -55 °C … +100 °C
    (-67 °F …+212 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Process connection hygienic

    Non- contact

Hydrostatic Level measurement Waterpilot FMX21

Reliable and robust level probe with ceramic measuring cell and HART

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Compact probe with ceramic cell for hydrostatic level measurement,
    Diameter = 22 mm: General applications, fresh water
    Diameter = 42 mm: Waste water applications
    Diameter = 29 mm: Salt water applications

  • Supply voltage

    10.5 …35V DC

  • Reference Accuracy

    0.2%
    0.1% (optional)

  • Long term stability

    0.1% of URL/year

  • Process temperature

    -10°C…70°C
    (14°F…158°F)
    Diameter 29 mm (1.14″): 0°C…50°C
    (32°F…122°F)

  • Ambient temperature

    -10°C…70°C
    (14°F…158°F)
    Diameter 29 mm (1.14″):
    0°C…50°C
    (32°F…122°F)

  • Measuring cell

    100mbar…20bar
    (1.5psi…300psi)

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Communication

    4…20 mA
    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

  • Marine approvals

    GL/ ABS/ BV/ DNV/ LR

  • Drinking water approvals

    NSF/ KTW/ ACS

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Compact probe with ceramic cell for hydrostatic level measurement,
    Diameter = 22 mm: General applications, Fresh water
    Diameter = 42 mm: Waste water applications
    Diameter = 29 mm: Salt water applications

  • Specialities

    Automatic density compensation
    Version w/o metal parts in contact to process

  • Supply / Communication

    10.5 …35 VDC

  • Accuracy

    0.2%
    0.1% (optional)

  • Long term stability

    0.1% of URL/year

  • Ambient temperature

    -10°C…70°C
    (14°F…158°F)
    Diameter 29 mm (1.14″):
    0°C…50°C
    (32°F…122°F)

  • Process temperature

    -10°C…70°C
    (14°F…158°F)
    Diameter 29 mm (1.14″): 0°C…50°C
    (32°F…122°F)

  • Pressure measuring range

    100 mbar…20 bar
    (1.5 psi…300 psi)

  • Main wetted parts

    Diameter 22 mm and 42 mm: Seal, 316L, Ceramic
    Diameter 29 mm: Seal, PPS, Polyolefin, Ceramic
    Extension cable: PE, PUR, FEP

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Max. measurement distance

    200 m H2O
    (656 ft H2O)

Hydrostatic Level measurement Waterpilot FMX11

Simple and reliable level probe for freshwater applications

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply voltage

    8…28 VDC

  • Reference Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1 % of URL/year

  • Process temperature

    -10°C…+70°C
    (+14°F…+158°F)

  • Ambient temperature

    -10°C…+70°C
    (+14°F…+158°F)

  • Measuring cell

    200 mbar…2 bar
    (3 psi…29 psi)

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Material process membrane

    Metal

  • Communication

    4…20 mA

  • Drinking water approvals

    NSF, KTW, ACS

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply / Communication

    8…28 VDC

  • Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1% of URL/year

  • Ambient temperature

    -10°C…+70°C
    (+14°F…+158°F)

  • Process temperature

    -10°C…+70°C
    (+14°F…+158°F)

  • Process pressure / max. overpressure limit

    10 bar (145 psi)

  • Pressure measuring range

    200 mbar…2 bar
    (3 psi…29 psi)

  • Main wetted parts

    316L

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Max. measurement distance

    20 m H2O
    (66 ft H2O)

  • Communication

    4…20 mA

  • Drinking water approvals

    NSF, KTW, ACS

Field of application
The Waterpilot FMX11 transmitter is typically used in environmental applications for hydrostatic level measurement. It is certified for drinking water applications and can be used in wells, storage tanks, water towers, dams, gauging stations, lakes and rivers.

Temperature: –10 to +70°C (14 to 158°F)
Measuring range: 0 to 2bar / 20m H20 (0 to 30psi / 67ft H2O)
Cable length: 6 to 30m
Accuracy: up to ±0.35%
Drinking water approvals: ACS, KTW, NSF61, DVGW
Certifications: cULus

Benefits
Simple and reliable transmitter for various drinking water applicationsEasy installation, commissioning and operation Orderable with flexible measuring ranges and cable lengths tailored to fit your application Robust construction for durable long-term services Suitable for surface water monitoring in rivers and lakes as well as level monitoring for drinking water production, e.g. in water towers, dams, gauging stationsCompact size d=22mm (0.87”), makes this an excellent choice for applications in bore holes and small diameter stilling wells.Simple specification and ordering

Radar measurement Micropilot FMR67

The standard sensor for highest demands in bulk solids level measurement with 80GHz technology

  • Measuring principle

    Level radar solid

  • Characteristic / Application

    Reliable, non-contact level measurement for high silos, bunkers or stockpiles, especially with many obstacles, long measuring range and build-up forming media.

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Very small beam angle,
    Safety and reliability with Multi- Echo Tracking,
    HistoROM,
    RFID TAG for easy identification,
    Air purge connection,
    Alignment device

  • Supply / Communication

    2-wire (HART),
    Bluetooth® wireless technology and App (optional)

  • Frequency

    W-band (~80 GHz)

  • Accuracy

    +/- 3 mm (0.12 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+200 °C
    (-40…+392 °F)

  • Main wetted parts

    PTFE, 316L
    Alignment device: Alu

  • Process connection

    Thread:
    G1-1/2″, MNPT1-1/2″;
    Flanges:
    DN80…DN100
    ASME 3″…4″
    UNI DN80…DN250 (3″…10″)

  • Max. measurement distance

    125 m (410 ft)

  • Communication

    4…20 mA HART
    Additional switch,
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, JPN Ex, UK Ex

  • Safety approvals

    SIL2, SIL3

  • Options

    Remote operation via SmartBlue App using Bluetooth®

Field of application
Micropilot FMR67 is the first 80GHz radar developed according to the international functional safety directive IEC 61508. It offers maximum reliability due to the drip-off antenna, improved focusing and very small emitting angles which is perfect for the measuring in slim silos. FMR67 is used for continuous, non-contact level measurement in powdery to granular bulk solids. FMR67 also possesses the smart sensor functionality Heartbeat Technology.

Micropilot FMR67 is suited for free space applications up to 125m and offers high beam focusing for vessels with many internal fittings.
Process connections: Threads or flanges
Temperature: -40 to +200°C (-40 to +392°F)
Pressure: –1 to +16bar (–14.5 to +232psi)
Maximum measuring range: 125m (410ft)
Accuracy: ±3mm (0.12in)
W-band: 80GHz
International explosion protection certificates, SIL, marine approvals, 5-point linearity protocol

Benefits
Hardware and software developed according to IEC 61508 up to SIL3 in homogeneous redundancy Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics Highest reliability even with obstructions in vessels due to small beam angle and Multi-Echo Tracking evaluation Innovative drip-off antenna of PTFE for maximum system availability Reduction of engineering effort due to an easier integration of the 80GHz radar instrument into the process The world’s easiest proof test concept for SIL saves time and costs

Radar measurement Micropilot FMR62

For 80GHz level measurement in aggressive liquids or applications with hygiene requirements

  • Measuring principle

    Level radar

  • Characteristic / Application

    Premium device for continuous non-contact level measurement,
    in which aggressive media are used as well as for highest hygiene requirements (ASME
    BPE, USP Class VI); For applications with many obstacles for small vessels due to the very small beam angle.

  • Specialities

    Heartbeat Technology
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi-Echo Tracking,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART),
    Bluetooth® wireless technology and App (optional)

  • Frequency

    W-band (~80 GHz)

  • Accuracy

    +/- 1 mm (0.04 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+200 °C
    (-40…+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…+25 bar
    (Vacuum…+362.6 psi)

  • Main wetted parts

    PTFE or PEEK antenna,
    316L threads,
    PTFE cladded flanges

  • Process connection

    Threads:
    G, MNPT 3/4″, 1-1/2″
    Flanges:
    DN50 … DN150
    ASME 2″ …6″

  • Process connection hygienic

    DIN11851, Tri-Clamp

  • Max. measurement distance

    80 m (262 ft)

  • Communication

    4…20 mA HART,
    Additional switch,
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG,
    SIL 2, SIL 3

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    AD2000

  • Hygienic approvals

    CoC-ASME BPE

  • Options

    Display,
    Customized parameterization,
    Remote operation via SmartBlue App using Bluetooth®,
    PWIS free,
    Gastight feed through

  • Application limits

Radar measurement Micropilot FMR60

The standard sensor for highest demands in liquid level measurement with 80GHz technology

  • Measuring principle

    Level radar

  • Characteristic / Application

    For basic level measurement in liquids, pastes and slurries;
    non affected by changing media, temperature changes, gas blankets or vapor;
    For applications with many obstacles due to the very small beam angle.

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi-Echo Tracking
    HistoROM
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Frequency

    W-band (~80 GHz)

  • Accuracy

    +/- 1 mm (0.04 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+130 °C
    (-40…+266 °F)

  • Process pressure / max. overpressure limit

    Vacuum …16 bar
    (Vacuum … 232 psi)

  • Main wetted parts

    PTFE antenna
    PP or 316L process connections

  • Process connection

    Thread:
    G1-1/2″, MNPT1-1/2″;
    Flange:
    UNI DN80…DN150 (3″…6″)

  • Max. measurement distance

    50 m (164 ft)

  • Communication

    4…20 mA HART,
    Additional switch,
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL 2, SIL 3

  • Design approvals

    EN 10204-3.1

  • Options

    Display,
    Customized parameterization,
    Remote operation via SmartBlue App using Bluetooth®,
    Gas-tight feed through,
    PWIS free

  • Application limits

    Process temp. > 130 °C (266 °F) -> FMR62
    Very aggressive media -> FMR62
    Strong turbulences and foam, stilling well and bypass -> FMR5x, FMP5x

Field of application
Micropilot FMR60 is the first 80GHz radar developed according to the international functional safety directive IEC 61508. The free space radar offers maximum reliability due to the drip-off antenna, improved algorithms and small beam angle. It is used for continuous non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. It also possesses the smart sensor functionality Heartbeat Technology.

80GHz drip-off antenna suited for free space applications up to 50m and offers high beam focusing for vessels with many internal fittings.
Process connections: Threads or flanges
Temperature: –40 to +130°C (–40 to +266°F)
Pressure: –1 to +16bar (–14.5 to +232psi)
Maximum measuring range: 50m (164ft)
Accuracy: ±1mm (0.04in)
W-band: 80GHz
International explosion protection certificates, overfill prevention WHG, SIL, marine approvals, 5-point linearity protocol

Benefits
Hardware and software developed according to IEC 61508 up to SIL3 in homogeneous redundancy Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics Highest reliability even with obstructions in vessels due to small beam angle and Multi-Echo Tracking evaluation Reduction of engineering effort due to an easier integration of the 80GHz radar instrument into the process Innovative drip-off antenna of PTFE for maximum system availability The world’s easiest proof test concept for SIL and WHG saves time and costs

Radar measurement Time-of-Flight Micropilot FMR56

Economically efficient basis model for level measurement in solids

  • Measuring principle

    Level radar solid

  • Characteristic / Application

    For simple applications:
    Reliable non-contact level measurements in silos or storage tanks for bulk solids

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi- Echo Tracking,
    HistoROM,
    RFID TAG for easy identification,

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Frequency

    K-band (~26 GHz)

  • Antenna

    Horn DN80/3″, PP plated
    Horn DN100/4″, PP plated

  • Accuracy

    +/- 3 mm (0.12 in)

  • Ambient temperature

    -40 °C…+80 °C
    (-40 °F…+176 °F)

  • Process temperature

    -40 °C…+80 °C
    (-40 °F…+176 °F)

  • Process pressure / max. overpressure limit

    Vacuum…3 bar
    (Vacuum…43.5 psi)

  • Main wetted parts

    PP, UP

  • Process connection

    Flange:
    UNI DN80…DN150
    (3″…6″)
    Mounting bracket

  • Max. measurement distance

    30 m (98 ft)

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC Ex, KC, UK Ex

  • Safety approvals

    SIL

  • Options

    Display,
    Customized parameterization
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    DK < 1.6
    Reduction of the max. possible measuring range through:
    Media with poor reflection properties
    Angle of repose
    Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling
    Build-up, above all of moist products

Field of application
Micropilot FMR56 is particularly designed for light-duty process conditions as they occur in silos or bins for solids. Micropilot free space radar is used for continuous, non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.

PP-plated horn antenna can be easily aligned to the surface of the solids by the mounting bracket or a turnable seal.Process connections: Mounting bracket or slip-on flangeTemperature: -40 to +80°C (-40 to +176°F)Pressure: -1 to +3bar (-14.5 to +43.5psi)Maximum measuring range: 30m (98ft)K-band: 26GHzInternational explosion protection certificates, SIL, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test concept for SIL and WHG saves time and cost

Radar measurement Time-of-Flight Micropilot FMR50

Basic model for level liquid applications

  • Measuring principle

    Level radar

  • Characteristic / Application

    For basic level measurement in liquids, pastes and slurries; non affected by changing media, temperature changes, gas blankets or vapor;
    Encapsulated PVDF or PP clad horn antenna

  • Specialities

    Heartbeat Technology,
    SIL 2 according to IEC 61508,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi-Echo Tracking,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 2 mm (0.08 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+130 °C
    (-40…+266 °F)

  • Process pressure / max. overpressure limit

    Vacuum…3 bar
    (Vacuum…43.5 psi)

  • Main wetted parts

    PVDF, Viton, PP, PBT

  • Process connection

    Thread:
    G1 1/2, MNPT1 1/2
    Flange:
    UNI DN80…DN150 (3″…6″)

  • Max. measurement distance

    Standard: 30 m (98 ft)
    With advanced dynamics: 40 m (131 ft)

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Options

    Display,
    Customized parameterization,
    PWIS free,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Ammoniacal gas phase:
    FMR54 in stilling well
    Strong build-up formation:
    FMR54 with air purge
    Low DK:
    FMR51
    Only PTFE resistant:
    FMR52
    Custody transfer measurement:
    FMR5xx

Field of application
Micropilot FMR50 is the best choice in simple reservoir and storage applications as well as in utility processes. The FMR50 free space radar is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. Remote access with SmartBlue app via Bluetooth module is available.

Encapsulated PVDF or PP-plated horn antenna.
Process connections: Thread, mounting bracket or slip-on flange
Temperature: -40 to +130°C (-40 to +266°F)
Pressure: -1 to +3bar (-14.5 to +43.5psi)
Maximum measuring range: 30m (98ft), 40m (131ft) for enhanced dynamics
Accuracy: ±2mm
K-band: 26GHz
International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Benefits
Reliable non-contact measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test concept for SIL and WHG saves time and cost

Electromechanical Level measurement Silopilot FMM50

For continuous level measurement even in high bulk solids silos or bins

  • Measuring principle

    Electromechanical

  • Characteristic / Application

    Not affected by characteristics of solid medium
    Mesuring range: 70m

  • Specialities

    Switch to indicate need of maintenance (predictive maintenance)

  • Supply / Communication

    180 … 253 V, 50/60 Hz

  • Accuracy

    +/- 5 cm

  • Ambient temperature

    -40°C … +70°C
    (-40°F … 158°F)

  • Process temperature

    -20°C … +230°C
    (-4°F … 446°F)

  • Process pressure / max. overpressure limit

    0.8 … 3 bar abs.
    (11.6psi …43.5psi abs.)

  • Main wetted parts

    Aluminium, Steel, Stainless steel

  • Process connection

    Flange DN100 PN16 / 4″

  • Blocking distance

    Top: 500 mm (20 “)

  • Max. measurement distance

    70m (230ft)

  • Communication

    0/4…20 mA

  • Certificates / Approvals

    ATEX

  • Design approvals

    EN10204-3.1

Field of application
Silopilot FMM50 is an electromechanical level system. Depending on the sensing weight, the level can be measured in bins or silos with dusty, fine-grained or coarse-grained bulk solids or in tanks with liquids.

For level measurement in bunkers or silos for dusty, fine or coarse-grained bulk products, or in tanks containing liquids.
Process connection: Flange
Temperature: -40 to +230°C (-40 to +446°F)
Pressure: 0.8 to 3bar (11.6 to 43.5psi)
Measuring range: 70m (230ft)
Accuracy: ±5cm (1.97″)
International explosion protection certificates

Benefits
High reliability level measurement of powdery, fine-grained or coarse-grained bulk solidsSafe measurements in extremely dusty environments Fully electronic digital minimum fail-safe control, therefore no running down of the sensor weight into the silo outlet and no risk to the conveying systems Quick menu-guided local operation using a 4-line text displayHigh performance three-phase engine (traction power up to 500N) using a single-phase supply voltage by employment of a converter, therefore simple electric supply Optional design with certification for application in areas subject to dust explosion hazard zones 20, 21 and 22 (measuring zone) or zones 21 and 22 (device zone), category 1/2D

Electromechanical Level measurement Silopilot FMM20

Basic model for continuous level measurement in light bulk solids

  • Measuring principle

    Electromechanical

  • Characteristic / Application

    Not affected by characteristics of solid medium
    Mesuring range: 32m

  • Specialities

    Switch to indicate need of maintenance (predictive maintenance)

  • Supply / Communication

    90… 253V, 50/60Hz
    20 – 28 VDC

  • Accuracy

    +/- 2.5 cm (0.98″)

  • Ambient temperature

    -40°C … +60°C
    (-40°F…140°F)

  • Process temperature

    -20°C … +150°C
    (-4°F…302°F)

  • Process pressure / max. overpressure limit

    0.8 … 1.1 bar abs.
    (11.6psi …15.95psi abs.)

  • Main wetted parts

    Aluminium, Steel, Stainless steel

  • Process connection

    Flange DN100 PN16 / 4″

  • Blocking distance

    Top: 500mm (20″)

  • Max. measurement distance

    32m (105ft)

  • Communication

    0/4…20 mA

  • Certificates / Approvals

    ATEX

Field of application
Silopilot FMM20 is a low cost device for electromechanical level measurement in bins or silos with dusty, fine-grained or coarse grained bulk solids or in tanks with liquids.

For measurement of light bulk solids such as wheat, plastic granules and powder in bunkers or silos with dusty, fine-grain or coarse-grain bulk solids.
Process connection: Flange
Temperature: -20 to +150°C (-4 to +302°F)
Pressure: 0.8 to 1.1bar (11.6 to 15.95psi)
Measuring range: 32m (105ft)
Accuracy: ±2.5cm (0.98″)
International explosion protection certificates

Benefits
Tried and tested, reliable measurement of light bulk solids, e.g. cereals, plastic granulate, powderSafe measurements in extremely dusty environmentsFully electronic digital minimum fail-safe control, therefore no running down of the sensor weight into the silo outlet and no risk to the conveying systems Quick menu-guided local operation using a 4-line text displaySupply voltage 90 to 253VAC (wide-range voltage power unit) as well as 24VDC, depending on version selected

Capacitance Level measurement Liquicap FMI52

For continuous level and interface measurement in liquids – for large measuring ranges

  • Measuring principle

    Capacitive

  • Characteristic / Application

    Fully insulated rope probe, for standard and extreme process conditions (temperature, pressure)

  • Interface measurement

    Interfaces liquid / liquid also with emulsion layers

  • Specialities

    Inactive length
    Factory calibrated
    short response time by change of value

  • Supply / Communication

    12-36V DC HART
    PFM

  • Accuracy

    repeatablity 0,1%

  • Linearity error for conductive liquids

    <0,25%

  • Ambient temperature

    -50°C…+70°C
    -58°F…+158°F

  • Process temperature

    -80°C…200°C
    -112°F…392°F

  • Process pressure / max. overpressure limit

    Vacuum … 100 bar
    (Vaccum … 1450 psi)

  • Main wetted parts

    Insulation material: FEP,PFA
    316L

  • Process connection

    G 3/4, G 1, G1 1/2 /NPT 3/4″, NPT 1, NPT1 1/2″
    Flange from DN25…/ASME 1″…/JIS…

  • Process connection hygienic

    Tri-Clamp ISO02852 gap free plated
    Dairy coupling
    Flush-mounted seal

  • Sensor length

    Total length: 6m (20ft)
    Inactive length: max. 2m (7ft)

  • Max. measurement distance

    0.42 m … 10.0 m
    (1.38 ft … 33 ft)

  • Communication

    4…20mA HART
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175

  • Hygienic approvals

    EHEDG

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Separate housing
    gas-tight probe seal

  • Application limits

    Changing, non-conductive
    media, conductivity
    < 100 μS/cm
    Notice the pressure and temperature derating

Field of application
Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks, build-up forming media and extremely high temperatures – especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.

Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
Process connections: Flanges and threads
Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
Measuring range: 0.42 to 10.0m (1.38 to 33ft)
Temperature: -80 to +200°C (-112 to +392°F)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals

Benefits
Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508Reliable and universal application thanks to wide range of certificates and approvals No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higherMaterial in contact with the process made of corrosion-resistant materialMenu-guided local configuration via plain text display (optional) Two-stage overvoltage protection

Capacitance Level measurement Liquicap FMI21

For continuous level measurement in conductive liquids

  • Measuring principle

    Capacitive

  • Characteristic / Application

    Two-rod probe
    Preconfigured from factory 0%…100%
    High quality, non-corrosive materials (carbon fibre, stainless steel)
    Suitable for aggressive liquids (many acids and alkalis)

  • Specialities

    Probe shorting kit available

  • Supply / Communication

    10 … 30VDC

  • Accuracy

    < 1%

  • Ambient temperature

    -40 °C … 70 °C
    (-40 °F … 158 °F)

  • Process temperature

    -40 °C … 100 °C
    (-40 °F … 212 °F)

  • Process pressure / max. overpressure limit

    Vacuum … 10 bar
    (Vacuum … 145 psi)

  • Main wetted parts

    Probe rods:
    316L/1.4404 / PP
    Option: carbon fibre PP coated

  • Process connection

    G 1½
    NPT 1½

  • Sensor length

    Total length of probe 2.5 m

  • Max. measurement distance

    2.5 m (8 ft)

  • Communication

    4 … 20 mA

  • Certificates / Approvals

    ATEX, CSA, CSA C/US

  • Safety approvals

    Overfill prevention WHG

  • Options

    Display

  • Application limits

    Changing, non-conductive
    media, conductivity
    < 3 0 μS/cm
    Highly viscous liquids
    > 2 000 cst

Field of application
Liquicap FMI21 is a simple and cost-effective rod probe for continuous level measurement for conductive liquids. High quality non-corrosive materials (carbon fibre, stainless steel) make it suitable even for aggressive liquids (e.g. acids and alkalis). Used in conjunction with the Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.

The device is preconfigured from factory 0 to 100% to probe length ordered. It can be used as of a conductivity of 30μS/cm and the measurement is independent of the dc-value (dielectric constant) of the liquid. Suited for cistern measurements.
Process connection: Thread
Process pressure: Vacuum to 10bar (vacuum to 145psi)
Measuring range: Up to 2.5m (8ft)
Temperature: -40 to +100°C (-40 to +212°F)
International explosion protection certificates, overfill prevention WHG

Benefits
Safe and reliable function regardless of tank geometryNo calibration necessary (factory preconfiguration)High quality, non-corrosive materials (carbon fibre, stainless steel) for use in aggressive liquidsNo moving parts in tankCost-effective solution for continuous level measurementOptimized storage by simply shortening the probe rods on site

Radiometric measurement Gamma Modulator FHG65

Effective suppression of background radiation and extraneous radiation at the Gammapilot FMG50

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Radiometric Measurement
    Effective Suppression of Background Radiation and Extraneous
    Radiation at the Gammapilot FMG60

  • Specialities

    Unhindered measurement with Gammapilot M
    FMG60 in the event of
    -Interference radiation from nondestructive material testing up to 50 μSv/h
    – Fluctuating background radiation

  • Supply / Communication

    DC: 18-36V

  • Ambient temperature

    -40°C …60°C
    (-40°F … 140°F)
    with cooling jacket:
    0°C …120°C
    (32°F …248 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Process connection hygienic

    Non-contact

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, NEPSI

  • Components

    Synchronizer FHG66

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Effective Suppression of Background Radiation and Extraneous
    Radiation at the Gammapilot FMG60

  • Specialities

    Unhindered measurement with Gammapilot M
    FMG60 in the event of
    -Interference radiation from nondestructive material testing up to 50 μSv/h
    – Fluctuating background radiation

  • Supply / Communication

    DC: 18-36V

  • Ambient temperature

    -40°C …60°C
    (-40°F … 140°F)
    with cooling jacket:
    0°C …120°C
    (32°F …248 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Process connection hygienic

    Non-contact

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, NEPSI

  • Components

    Synchronizer FHG66

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Radiometric Measurement
    Effective Suppression of Background Radiation and Extraneous
    Radiation at the Gammapilot FMG60

  • Specialities

    Unhindered measurement with Gammapilot M
    FMG60 in the event of
    -Interference radiation from nondestructive material testing up to 50 μSv/h
    – Fluctuating background radiation

  • Supply / Communication

    DC: 18-36V

  • Ambient temperature

    -40°C …60°C
    (-40°F … 140°F)
    with cooling jacket:
    0°C …120°C
    (32°F …248 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

Modular holder system Flexdip CYH112

Holder for in-situ measurement in water, wastewater and utilities

  • Measuring principle

    Potentiometric

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    The holder system CYH112 works for nearly any type of fixing:
    Fixing on the floor, wall or directly on a rail

  • Material

    Main pipe, transverse pipe: stainless steel 1.4404
    Chain: PA or stainless steel 1.4401

  • Process temperature

    -20 to 60 °C (-4 to 140 °F)

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    The holder system CYH112 works for nearly any type of fixing:
    Fixing on the floor, wall or directly on a rail

  • Material

    Main pipe, transverse pipe: stainless steel 1.4404
    Chain: PA or stainless steel 1.4401

  • Process temperature

    -20 to 60 °C (-4 to 140 °F)

  • Measuring principle

    Conductive

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    The holder system CYH112 works for nearly any type of fixing:
    Fixing on the floor, wall or directly on a rail

  • Material

    Main pipe, transverse pipe: stainless steel 1.4404
    Chain: PA or stainless steel 1.4401

  • Process temperature

    -20 to 60 °C (-4 to 140 °F)

  • Measuring principle

    Amperometric oxygen measurement

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    The holder system CYH112 works for nearly any type of fixing:
    Fixing on the floor, wall or directly on a rail

  • Material

    Main pipe, transverse pipe: stainless steel 1.4404
    Chain: PA or stainless steel 1.4401

  • Process temperature

    -20 to 60 °C (-4 to 140 °F)

  • Measuring principle

    Total chlorine

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    The holder system CYH112 works for nearly any type of fixing:
    Fixing on the floor, wall or directly on a rail

Immersion assembly Flexdip CYA112

Modular assembly for water, wastewater and utilities

  • Measuring principle

    Potentiometric

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYA112 is a modular assembly system for sensors in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    Versions in stainless steel or PVC

  • Material

    Immersion pipe, connection angle, welded threads: stainless steel 1.4404
    Sensor adaption, quick fastener, multifunctional clamp ring: POM – GF
    O-rings: EPDM

  • Dimension

    Immersion pipe diameter: 40 mm (1.57 inch)
    Length: 600, 1200, 1800 and 2400 mm
    (23.6, 47.2, 70.9 and 94.5 inch)

  • Process temperature

    0 to 60 °C (32 to 140 °F)

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYA112 is a modular assembly system for sensors in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    Versions in stainless steel or PVC

  • Material

    Immersion pipe, connection angle, welded threads: stainless steel 1.4404
    Sensor adaption, quick fastener, multifunctional clamp ring: POM – GF
    O-rings: EPDM

  • Dimension

    Immersion pipe diameter: 40 mm (1.57 inch)
    Length: 600, 1200, 1800 and 2400 mm
    (23.6, 47.2, 70.9 and 94.5 inch)

  • Process temperature

    0 to 60 °C (32 to 140 °F)

  • Measuring principle

    Conductive

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYA112 is a modular assembly system for sensors in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    Versions in stainless steel or PVC

  • Material

    Immersion pipe, connection angle, welded threads: stainless steel 1.4404
    Sensor adaption, quick fastener, multifunctional clamp ring: POM – GF
    O-rings: EPDM

  • Dimension

    Tauchrohr Durchmesser: 40 mm (1.57 Zoll)
    Länge: 600, 1200, 1800 und 2400 mm
    (23.6, 47.2, 70.9 und 94.5 Zoll)

  • Process temperature

    0 … 60 °C (32 … 140 °F)

  • Measuring principle

    Amperometric oxygen measurement

  • Application

    Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

  • Installation

    CYA112 is a modular assembly system for sensors in open basins, channels and tanks

  • Characteristic

    Simple and easy installation
    Universal and flexible

  • Design

    Versions in stainless steel or PVC

  • Material

    Immersion pipe, connection angle, welded threads: stainless steel 1.4404
    Sensor adaption, quick fastener, multifunctional clamp ring: POM – GF
    O-rings: EPDM

  • Dimension

    Immersion pipe diameter: 40 mm (1.57 inch)
    Length: 600, 1200, 1800 and 2400 mm
    (23.6, 47.2, 70.9 and 94.5 inch)

  • Process temperature

    0 to 60 °C (32 to 140 °F)

    Suspended solids sensor Turbimax CUS51D

    Memosens sensor for suspended solids and turbidity measurement in water, wastewater and utilities

    • Measuring principle

      Four beam alternating light

    • Application

      Wastewater, process water and primary water treatment applications.
      Turbidity and suspended solids measurement at all stages of the wastewater treatment process and at primary water treatment applications with medium to high turbidities.

    • Installation

      Insitu (immersion in process or retractable holder), extractive with sample and flow cell

    • Design

      40 mm sensor, stainless steel

    • Dimension

      194 mm x 40 mm

    • Material

      Stainless steel 316L

    • Measurement range

      For formazin: 0 to 4000 FNU
      Display range up to 9999 FNU
      For sludge: 0 to 300 g/L
      The achievable measuring range depends very much on the media

    • Connection

      G1, NPT3/4″

    • Ingress protection

      IP68 (1 m / 3.3 ft) water column with 1N KCl during 60 days

    • Measuring principle

      Four beam alternating light

    • Application

      Wastewater, process water and primary water treatment applications.
      Turbidity and suspended solids measurement at all stages of the wastewater treatment process and at primary water treatment applications with medium to high turbidities.

    • Installation

      Insitu (immersion in process or retractable holder), extractive with sample and flow cell

    • Measurement range

      For formazin: 0 to 4000 FNU
      Display range up to 9999 FNU
      For sludge: 0 to 300 g/L
      The achievable measuring range depends very much on the media

    • Measuring principle

      Scattered light in 90°/135° and 4beam cross light

    • Design

      40 mm sensor, stainless steel

    • Material

      Stainless steel 316L

    • Dimension

      194 mm x 40 mm

    • Process temperature

      Process temperature:
      -5 to 50 °C (23 to 122 °F)
      Ambient temperature:
      -20 to 60 °C (-4 to 140 °F)

    • Connection

      G1, NPT3/4″

    • Ingress protection

      IP68 (1 m / 3.3 ft) water column with 1N KCl during 60 days

    Field of application
    Turbimax CUS51D is a smart sensor that allows unattended operation in a wide range of process conditions. Its unique design is extremely robust and it is also low-maintenance thanks to its self-cleaning functionality. Choose from different integrated analytical models to adapt the sensor to your specific application. With Memosens digital technology, the CUS51D combines maximum process and data integrity with simple operation. It resists corrosion and moisture and enables lab calibration.

    Turbimax CUS51D measures suspended solids and turbidity in:
    Wastewater treatment plants:- Solids content measurement in aeration, recirculation and sludge treatment- Flocculent dosing- Turbidity measurement in the outlet
    Drinking and process water:- Solids content measurement in sludge treatment- Flocculent dosing
    Utilities of all industries:- Solids content measurement in aeration, recirculation and sludge treatment- Flocculent dosing

    Benefits
    One sensor for all applications: The ‘one for all’ principle optimizes stockholding, speeds up project handling and simplifies life cycle management.Optimum adaption to all measuring tasks:Sensor fits all measuring ranges thanks to numerous integrated analytical models.Fast and easy commissioning: Sensor comes precalibrated and preconfigured ex factory. Enables unattended plant operation: Intelligent design enables sophisticated self-cleaning capabilities and minimizes maintenance. Perfect process adaption: Fast sensor positioning with holder and assembly system Flexdip CYA112 and CYH112.

    Digital pH sensor Ceragel CPS71D

    Memosens glass electrode for the chemical and life sciences industries

    • Measuring principle

      Potentiometric

    • Application

      Aggressive chemical and hygienic applications, process

    • Characteristic

      Analog, digital pH single-rod measuring cells
      For chemical process, hygienic and sterile applications with an ion trap for poison-resistant reference

    • Measurement range

      pH 0 to 14

    • Measuring principle

      Ceramic diaphragm, ion-trap

    • Design

      All shaft lengths with temperature sensor
      Advanced gel technology
      Digital electrode with Memosens technology

    • Material

      Glass and ceramic

    • Dimension

      Diameter: 12 mm (0.47 inch)
      Shaft lengths: 120, 225, 360 and 425 mm
      (4.72, 8.86, 14.2 and 16.7 inch)

    • Process temperature

      0 to 140 °C (32 to 284 °F)

    • Process pressure

      1 to 14 bar (15 to 203 psi)

    • Temperature sensor

      NTC 30k

    • Ex certification

      ATEX, FM, CSA

    • Connection

      Inductive, digital connection head with Memosens technology

    • Ingress protection

      IP68

    • Additional certifications

      3A, biocompatibility

    Field of application
    Ceragel CPS71D is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media or low conductivity. The sensor measures reliably at high temperatures and is non-toxic assuring highest safety. Ceragel CPS71D is not the latest Memosens generation. To get information on the new Memosens sensors with extended functionality, click CPS71E for chemical applications and CPS61E for hygienic applications.

    Process technology and monitoring of processes with:- Quickly changing pH values- High proportion of electrode poisons such as H2SChemical industryHygienic and sterile applications:- Fermenters- Biotechnology- Life sciencesWith ATEX, FM, and CSA approval for application in hazardous areas

    Benefits
    Sensor resists strong acids and bases and high organic loadsSuitable for CIP/SIP and autoclaving maintaining high accuracyFree from animal-based materials and from acrylamide Maximum process safety through non-contact inductive signal transmissionEnables predictive maintenance due to storage of sensor and process-specific data Reduced operating costs thanks to minimized process downtime and extended sensor lifetime

    Zero-point gel COY8

    Ready-to-use gel for validation, calibration, and adjustment of oxygen and disinfection sensors

    • Measuring principle

      Amperometric oxygen measurement

    • Application

      Zero point gel for oxygen sensor verification, adjustment or calibration

    • Measurement range

      Zero point

    • Dimension

      Available for 12 mm and 40 mm oxygen sensors

    • Measuring principle

      Amperometric oxygen measurement

    • Application

      Zero point gel for disinfection sensor adjustment

    • Measurement range

      Zero point

    • Dimension

      Available for 25 mm disinfection sensors

    Field of application
    COY8 is a ready-made gel that allows you to detect the true zero point of your oxygen and disinfection (e.g. free chlorine) sensors. This improves the reliability and accuracy of your measuring points leading to increased product quality and yield. What’s more, it helps you decide whether a sensor should be adjusted, maintained or replaced. The gel doesn’t require additional chemicals or preparation. It is instantly ready to use and is reusable within 24 hours after opening.

    COY8 zero-point gel determines the true zero point of virtually all sensors that measure the parameters:
    Oxygen
    Free chlorine
    Total chlorine
    Chlorine dioxide
    Etc.
    It is used for example in:
    Life Sciences- Fermentation processes
    Food & Beverages- Inertization processes
    Power & Energy- Steam/water cycle
    Drinking water- Distribution network- Critical control points (CCPs)
    Utilities of all industries- Water treatment

    Benefits
    Be sure: exact determination of the true zero of your oxygen and disinfection / chlorine measuring points.Enhance your product quality: the zero-point calibration improves the accuracy and reliability of your measurements and can increase the quality and yield of your products.Speed up your maintenance: the gel is instantly ready to use – just insert the sensor!Simplify your maintenance: one tool for validation, calibration and adjustment of all your sensors in the field and the lab.Improve safety at work: the ready-made gel comes in safe, easy-to-use bottles removing the need for manual chemical preparation by plant personnel.

    Digital conductivity sensor Indumax CLS54D

    Memosens toroidal conductivity sensor for hygienic and sterile applications

    • Measuring principle

      Inductive

    • Application

      Food, beverage and pharmaceutical industries, biotechnology, dairies, breweries

    • Characteristic

      Specifically intended for use in hygienic applications and especially suitable for following applications:
      Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring

    • Measurement range

      100 µS/cm to 2000 mS/cm
      Cell constant k: 6.3 1/cm

    • Measuring principle

      Inductive conductivity measurement

    • Design

      Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications

    • Material

      In contact with medium: virgin PEEK

    • Process temperature

      -10 °C to 125 °C (14 °F to 257 °F)
      Sterilization: 150 °C at 6 bar abs for max. 60 min
      (302 °F at 87 psi abs for max. 60 min)

    • Process pressure

      13 bar abs up to 90 °C (188.5 psi abs up to 194 °F)
      9 bar at 125 °C (130.5 psi abs at 257 °F)

    • Temperature sensor

      Pt1000 (Class A according to IEC 60751)

    • Connection

      Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2″, Varivent N DN 40-125, Neumo Biocontrol D50

    • Ingress protection

      IP68 / NEMA type 6P

    • Additional certifications

      FDA, EHEDG, 3-A
      Biological reactivity USP class VI part <87> and <88>

    Field of application
    The Indumax CLS54D inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products. Thanks to Memosens digital technology, Indumax CLS54D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration, and facilitates predictive maintenance.

    Indumax CLS54D measures toroidal conductivity in hygienic food & beverage and life science applications, such as:
    Phase separation of product/water and product/product mixtures in pipe systems
    Control of CIP (cleaning in place) processes in the return channel
    Concentration control in remaking of CIP cleaning agents
    Product monitoring in pipe systems, bottling plants, quality assurance
    Leakage monitoring

    Its unique hygienic design is certified by EHEDG and 3-A.

    Benefits
    Unique hygienic design avoids contaminationWith all hygienic certificates required in hygienic and sterile applications, compliant with EG 2023/2006 and 1935/2004Food grade virgin PEEK body without joints nor crevicesCertified biocompatibility according to USP class VISuitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)Convenient maintenance strategy with Memobase Plus for easy data and sensor managementReliable values thanks to active connection monitoring and EMC protection

    Conductivity compact device Smartec CLD134

    Toroidal conductivity measuring system for hygienic and sterile applications

    • Measuring principle

      Inductive

    • Application

      Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology

    • Characteristic

      Specifically intended for use in hygienic applications and especially suitable for following applications:
      Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring

    • Measurement range

      100 µS/cm to 2000 mS/cm
      Cell constant k : 6.3 1/cm

    • Measuring principle

      Inductive conductivity measurement

    • Design

      Hygienic design with FDA certified virgin PEEK body including all hygienic certifications

    • Material

      In contact with medium: Virgin PEEK

    • Process temperature

      Max. 125 °C (max. 257 °F)
      For sterilization: up to 150 °C for max. 60 min
      (up to 302 °F for max. 60 min)

    • Process pressure

      12 bar abs up to 90 °C
      (174 psi abs up to 194 °F)

    • Temperature sensor

      Pt 1000

    • Connection

      Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2″, Varivent N DN 40-125, Neumo Biocontrol D50

    • Ingress protection

      IP67

    • Output / communication

      Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus

    • Additional certifications

      FDA, EHEDG, 3A
      Biological reactivity USP class VI part <87> and <88>
      EC Regulation No. 1935/2004

    Field of application
    Smartec CLD134 is a measuring system for inductive conductivity in the food & beverage and life sciences industries. The combination of a transmitter and a sensor is interference-free and especially easy-to-use. It meets the highest hygienic and sterile demands thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates. Smartec CLD134 is therefore the ideal package to ensure the highest safety and quality of your products and processes.

    The hygienic Smartec CLD134 measures toroidal conductivity in food & beverage and life science applications:
    Phase separation of product/water and product/product mixtures in pipe systems
    Control of CIP processes in the return channel
    Concentration control in remaking of CIP cleaning agents
    Product monitoring in pipe systems, bottling plants, quality assurance
    Leakage monitoring

    It features the following protocols and interfaces:
    0/4…20mA
    HART
    PROFIBUS DP
    PROFIBUS PA

    Benefits
    Unique hygienic design avoids recontaminationWith all hygienic certificates required in hygienic and sterile applicationsCertified biocompatibility according to USP class VICompliant with EG 2023/2006 and 1935/2004 Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP) Durable thanks to encapsulated, jointless design

    Digital ozone sensor Memosens CCS58D

    Memosens sensor for drinking water, wastewater and process water in all industries

    • Measuring principle

      Ozone

    • Application

      Drinking water – ensures adequate disinfection
      Process water – for hygienic packaging and filling
      Wastewater – to ensure safe discharge water

    • Characteristic

      Amperometric measurement of dissolved ozone

    • Measurement range

      0 to 2 mg/l

    • Measuring method

      – closed 2 electrode system
      – conversion of ozone into a signal current in nA
      – signal current is proportional to the concentration of ozone
      – the measurement is not pH dependent

    • Design

      – exchangeable, electrolyte-filled membrane cap
      – working and counter electrode
      – adaptable shaft for flexible installation in assemblies

    • Material

      Sensor shaft: PVC
      Membrane: Silicone
      Membrane cap: PVC

    • Dimension

      Diameter: 25 mm (0.98 in)
      Length: 161 mm (6.34 in)

    • Process temperature

      +0 to 45 °C (32 to 110 °F), non freezing

    • Process pressure

      1 bar (14.5 psi), 2 bar (29 psi) absolute

    • Temperature sensor

      10k NTC integrated (Memosens)

    • Connection

      Inductive, digital connection head with Memosens

    Field of application
    Memosens CCS58D is a low-maintenance sensor for ozone. It provides high-precision measurement with an almost exclusive specificity for ozone, ensuring reliable disinfection monitoring. The robust sensor membrane with its high surfactant resistance makes the sensor suitable for diverse applications, e.g. bottle cleaning. Memosens CCS58D is not the latest Memosens generation. To get information on the new Memosens CCS58E sensor with extended functionality, click here.

    Memosens CCS58D is an ozone sensor for skid builders and end customers. It measures reliably in:Drinking water – to ensure sufficient disinfectionProcess water – to provide hygienic packaging and bottlingWastewater – to guarantee safe discharge water

    Benefits
    Almost exclusive specificity for ozone ensures reliable measured values for safe disinfection processes.Robust membrane technology guarantees high surfactant resistance and optimum suitability for cleaning processes such as bottle cleaning. Integrated Heartbeat Technology provides, for example, an electrolyte counter for predictive, application-specific maintenance intervals. Connection to the Liquiline multiparameter transmitter allows for easy combination with other relevant parameters of liquid analysis such as pH and ORP. Fast commissioning is ensured by factory-calibration and plug & play installation of the sensor.

    Analog free chlorine sensor CCS51

    Sensor for drinking water, pool and process water as well as utilities in all industries

    • Measuring principle

      Free chlorine

    • Application

      Drinking water – to ensure reliable disinfection
      Process water – wide range of application due to large measuring range
      Food – to secure absence/presence of free chlorine
      Pool water -efficient dosing thanks to precise measurement

    • Characteristic

      Amperometric measurement of dissolved free chlorine

    • Measurement range

      Trace: 0 to 5 mg/l HOCl
      Standard: 0 to 20 mg/l HOCl

    • Measuring method

      – Closed, membrane covered measuring cell
      – Reduction of free chlorine at the cathode

    • Design

      Closed amperometric 2-electrode measuring cell with PVDF membrane

    • Material

      Sensor shaft: POM
      Membrane: PVDF
      Membrane cap: PVDF

    • Dimension

      Diameter: 25 mm (0.98 in)
      Length: 161 mm (6.34 in)

    • Process temperature

      +0 to 55 °C (32 to 130°F), non-freezing

    • Process pressure

      1 bar (14.5 psi)

    • Temperature sensor

      10k NTC

    • Connection

      analog with fixed cable

    Field of application
    CCS51 is a robust, low-maintenance sensor for free chlorine. It provides high-precision measurement with long-term stability in drinking water, pool and process water and ensures consistent disinfection monitoring even at low water volumes. The analog free chlorine sensor features extremely fast response times guaranteeing efficient process control and safe processes. CCS51 ensures continuity for the installed base of analog free chlorine measuring points.

    CCS51 is an analog free chlorine sensor for skid builders and end customers. It measures reliably in:Drinking water – to ensure reliable disinfectionProcess water – for hygienic and safe packaging and bottling of productsUtilities – to detect the absence or presence of free chlorinePool water – to dose disinfectant efficiently

    Benefits
    Fast response time (t90 < 25 s) provides accurate process view and enables prompt reaction to process changes as well as efficient process control. Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for individually adapted disinfectant dosing. The low-maintenance, amperometric sensor reduces the cost of ownership of the measuring point, particularly compared to colorimetric measuring systems. Connection to the Liquisys chlorine transmitter ensures continuity for the installed base of analog free chlorine measuring points.

    Flow assembly for chlorine dioxide sensors Flowfit CCA151

    Simple assembly for drinking and process water applications

    • Measuring principle

      Free chlorine

    • Application

      Drinking water
      Utilities of all industries
      For low sample flow

    • Characteristic

      Flow through assembly for one disinfection sensor

    • Design

      Flow assembly with direct inflow to the membran

    • Material

      Plexiglas (PMMA)

    • Dimension

      85 mm x 85 mm x 220 mm
      (3.35 inch x 3.35 inch x 8.64 inch)

    • Process temperature

      Max. 60 °C
      (Max. 140 °F)

    • Process pressure

      Max. 4 bar relative
      (Max. 58 psi relative)

    Field of application
    Flowfit CCA151 is a simple flow assembly for disinfection parameters such as chlorine dioxide that do not require pH compensation. Sensors installed in the acrylic glass assembly need only a sample flow as low as 5 l/h (1.32 gph) for accurate measurement. This enables precise control of disinfection processes with minimal water loss. Thanks to flexible mounting options for panels, walls and pipes, Flowfit CCA151 places the disinfection sensor at an optimal position for best measuring results.

    CCA151 is a flow assembly for the measurement of disinfection parameters without pH compensation, e.g. chlorine dioxide in:
    Drinking water
    Utilities of all industries
    Applications with low sample volumes

    Benefits
    Minimum water loss: When installed in Flowfit CCA151, sensors require a sample flow as low as 5 l/h (1.32 gph) for precise chlorine dioxide measurement. Only a very small volume of water goes to waste. Reliable measurement: Flexible mounting options allow you to position the sensor exactly where it is needed to accurately determine the chlorine dioxide content. Cost-effective update of your installed base: Easy replacement of CCA250 thanks to identical dimensions.

    Translate »