TP analyzer Liquiline System CA80TP
Total phosphorus analyzer for environmental monitoring, industrial and municipal wastewater
-
Measuring principle
Colorimetric
-
Characteristic
Analyzer for total phosphorus
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar
-
Sample flow rate
Min. 30 ml/min
-
Consistency of the sample
Low solid content (TS<50 mg/l), homogeneous
-
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Self-priming analyzer with optical dosing unit l
Dilution module (optional)
Digital communication for remote access -
Application
Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
Monitoring of the wastewater treatment plant outlet for documentation purposes
Monitoring and optimization of activated sludge basins -
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Webserver, Modbus, Ethernet/IP, Profibus DP -
Input
1 measuring channel
1 to 4 digitale sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
0 to 2 mg/l
0.05 to 10 mg/l
0.5 to 50 mg/l -
Consumables
Reagents and standard solutions CY80TP are necessary for the operation
Field of application
Phosphorus is the decisive factor for excessive algae and plant growth in water bodies, that’s why continuous monitoring of this parameter is essential. The Liquiline System TP analyzer offers precise online measurement of total phosphorus and ensures highest process safety. Automatic calibration and cleaning save you operating costs while advanced diagnostics with remote access support you in providing process documentation to the authorities.
The Liquiline System TP analyzer monitors:
Inlet and outlet of wastewater treatment plants for documentation purposes and calculation of the cleaning capacity
Discharges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principle
Process water
Benefits
Molybdenum blue method according to EN ISO 6878:2004 guarantees direct comparability to laboratory results Meeting industry needs: The analyzer is perfectly suited for environmental monitoring, industrial and municipal wastewater Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications Safety on the highest level: Software-controlled safety cover for the reactor and all heated parts. Additional safety light barrier prevents overdosing of reagents and sample. Combination of reliable sample delivery and high-precision dosing: Peristaltic pumps are able to cope with particles in the sample. Light barriers enable precise, reproducible dosing. Enhanced reagent lifetime thanks to optional cooling moduleEasy upgrade of functionality to a complete measuring station – simply by adding modules and connecting Memosens sensors.
Nitrite analyzer Liquiline System CA80NO
Colorimetric system for monitoring of drinking water, mineral water or raw water for food production
-
Measuring principle
Colorimetric
-
Characteristic
Process analyzer for Nitrite in potable water
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar absolute
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Optional cooling module for standard solution
2 channel version optional
User-definable measuring ranges
Modular design for easily extensible functionality -
Application
Limit value monitoring of nitrite for potable water and mineral water applications
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Modbus RS485/TCP (optional)
Ethernet (optional)
Alarmrelay -
Input
1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
10 to 500 µg/l NO2-N
0.2 to 3.0 mg/l NO2-N
0.1 to 1.0 mg/l NO2-N
0.1 to 1.0 mg/l with dilution function to maximum 5 to 50 mg/l NO2-N -
Consumables
Reagents and standard solutions CY80NO as well as cleaner CY800 are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
Field of application
Liquiline System CA80NO offers precise, regulation-compliant online measurement of nitrite. It supports you in meeting the specified limits in drinking water, mineral water or food production. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety.
Liquiline System CA80NO supports you in keeping the strict nitrite limits for: Drinking waterMineral waterRaw water for food production
Benefits
Compliance with standard colorimetric measuring principle – naphthylamine method – following ISO 6777 and DIN EN 26777 ensures comparability to lab measurements. Reduced operating costs through automatic calibration and cleaning. Simple maintenance: no tools required. Advanced diagnostics with remote access for increased process safety. Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation.Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors. Reduces installation effort.
Iron analyzer Liquiline System CA80FE
Colorimetric system for monitoring of drinking water, mineral water and process water
-
Measuring principle
Colorimetric
-
Characteristic
Process analyzer for iron in aqueous solutions
Comply with standard colorimetric measuring principle, ferrozine method -
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Application
Monitoring of the iron content of potable water, mineral water and source water for industrial processes
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Webserver, Modbus, Ethernet/IP, Profibus DP -
Input
1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
0.05 to 2 mg/l Fe
0.1 to 5 mg/l Fe
0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe -
Consumables
Reagents and standard solutions CY80FE for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
Field of application
Liquiline System CA80FE offers precise, regulation-compliant online measurement. It supports you in controlling the iron content of drinking water, mineral water or source water for industrial processes. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.
Liquiline System CA80FE monitors:Iron content in drinking water and mineral waterResidual iron after precipitation, flocculation and filtration processesProcess water containing diluted iron
Benefits
Compliance with standard ferrozine method ensures direct comparability to lab measurements Supports predictive maintenance by advanced diagnostics Reduced operating costs through automatic calibration and cleaning as well as low reagent consumption Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors. Comfortable remote access via integrated web server Seamless integration into process control systems thanks to digital field busses such as Modbus, PROFIBUS or EtherNet/IP
Chromate analyzer Liquiline System CA80CR
Colorimetric system for the monitoring of industrial wastewater and optimization of process control
-
Measuring principle
Colorimetric
-
Characteristic
Analyzer for Chromate (Chrome VI) in aqueous solutions
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar absolute
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Optional cooling module for longer reagent shelf life
2 channel version optional
User-definable measuring ranges
Modular design for easily extensible functionality
Digital communication for remote access -
Application
Limit value monitoring of Chromate in potable water and waste water
Common applications are industrial waste water Monitoring for tanneries and the galvanic industry -
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Modbus RS485/TCP (optional)
Ethernet (optional)
Alarmrelay -
Input
1 or 2 measuring channels
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
0,03 to 2.5 mg/l Cr(VI)
0.2 to 5.0 mg/l Cr(VI)
0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI) -
Consumables
Reagents and standard solutions CY80CR as well as cleaner CY800 are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
Field of application
Liquiline System CA80CR offers highly accurate online measurement for optimized chromate removal in industrial wastewater. It supports you in achieving environmentally compliant electroplating and tanning processes. Like all Liquiline System analyzers, CA80CR enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning plus advanced diagnostics with remote access ensure consistent process safety.
Liquiline System CA80CR supports you in improving the environmental performance of your processes by:
Monitoring and optimizing the cleaning capacity of industrial wastewater treatment plants.Effluent monitoring in tanneries and electroplating plants.
Monitoring of membrane filtration.Limit monitoring in drinking water applications.
Benefits
Standardized colorimetric measuring principle – diphenyle carbazide method – guarantees compliance with discharge regulations. Reduced operating costs through automatic calibration and cleaning and low reagent consumption. Simple maintenance: no tools required. Advanced diagnostics with remote access for increased process safety. Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation. Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors. Reduces installation effort.
Aluminum analyzer Liquiline System CA80AL
Colorimetric system for drinking water and wastewater monitoring and optimization of process control
-
Measuring principle
Colorimetric
-
Characteristic
Process analyzer for aluminum in aqueous solutions
Comply with standard colorimetric measuring principle – pyrocatechol violet methot -
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 … 40 °C (39.2 … 104 °F)
-
Ambient temperature
5 … 40C ( 41 … 104F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
at atmospheric pressure, < 0.2 bar
-
Sample flow rate
min. 5ml/min (0,17 fl.oz/min)
-
Consistency of the sample
low solid content (< 50NTU), aqueous homogeneous
-
Application
Monitoring of the aluminum content of potable water, mineral water and industrial waste water
-
Power supply
100 … 120 VAC / 200 … 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 oder 60 ± 1,2 Hz -
Output / communication
2x 0/4 … 20 mA
Webserver, Modbus, Ethernet/IP, Profibus DP -
Input
1 or 2 measuring channel
1 … 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
15 to 1000 µg/l Al
15 to 1000 µg/l with dilution function to maximum 300 to 20 000 µg/l Al -
Consumables
Reagents and standard solutions CY80AL as well as cleaner CY800 are necessary for the operation. Regular maintenance is done with the parts of the maintenance kit CAV800.
Field of application
Liquiline System CA80AL offers precise, regulation-compliant online measurement of aluminum residues in drinking water and wastewater. The analyzer helps you to optimize aluminum dosing in flocculation processes and phosphate removal. It enables plug & play of up to 4 Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.
Liquiline System CA80AL aluminum analyzer supports:Limit monitoring in drinking waterOptimization of aluminum-based coagulation processesPhosphate elimination in wastewater treatment plants
Benefits
The aluminum analyzer uses the pyrocatechol violet method according to DIN ISO 10566, ensuring direct comparability to lab results
Supports predictive maintenance by advanced diagnostics Reduces operating costs thanks to automatic calibration and cleaning as well as low reagent consumption
Easy upgrade of functionality to a complete measuring station – by adding modules and connecting Memosens sensors. Comfortable remote access via integrated web serverSeamless integration into process control systems thanks to digital field buses such as Modbus, PROFIBUS, EtherNet/IP
High temperature TOC analyzer CA72TOC
Reliable online monitoring of industrial wastewater
-
Measuring principle
UV photometric
-
Characteristic
Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion
-
Size
1558 x 785 x 400 mm
61.3 x 30.9 x 15.8 inch -
Design
IP54
-
Process temperature
0 to 40 °C (32 to 104 °F)
-
Ambient temperature
5 to 35 °C (41 to 95 °F)
-
Process pressure
Pressure free
-
Sample flow rate
20 ml/min (0.32 US gal/hr)
-
Consistency of the sample
Aqueous
Flammable substances are not allowed in ignitable concentrations, in such cases a sample dilution is required -
Specials
Heatable Salt Trap
Exchange furnace concept
pH-controlled acid dosage with TIC stripping -
Application
Industrial wastewater monitoring
Control of process wastewater
Monitoring of industrial surface water
Recording of the carbon load to control the nutrient dosage -
Power supply
115 VAC, 230 VAC, 50/60Hz
-
Output / communication
0/4 to 20 mA, galvanically separated
Two channel version has an addtional one
RS 232 C, propietary, for data output and remote control (optional) -
Input
8 signal inputs 24 V DC, ative, load max. 500 Ohm
-
Measurement range
0.25 to 600 mg TOC/l
1 to 2400 mg TOC/l
2.5 to 6000 mg TOC/l
5 to 12000 mg TOC/l
With the optional pre-dilution the measuring range will expand by the factor of 20 -
Consumables
Stripp reagent, KHP or citric acid standard
Field of application
CA72TOC determines the total organic carbon (TOC) content in a number of industries. It measures reliably and accurately even in heavy duty applications with high loads of salt, fat or fibers. The reliable detection of product losses increases the process yield and saves money every day. Designed for long-term stability and highest availability, the CA72TOC offers maximum operational safety of your plant. Clear diagnostic messages actively support your predictive maintenance strategy.
CA72TOC monitors and controls: Industrial discharge
Inlets of wastewater treatment plants
Outlets of wastewater treatment plants
Process water
Surface run-off
Benefits
Process optimization: Constant safeguard against product losses. Cost savings: 2-channel version offers an excellent price-performance ratio.Reliable discharge monitoring: Configuration for fat and grease, low pH values and organic acids.Improved process stability and safety: Immediate readjustment of the process based on online information.Robust design: Self-cleaning slit filter and automatic backflush function support long maintenance intervals.Safe and convenient operation: Remote access and diagnostics via serial interface.
iTHERM applications with limited access
iTHERM TM131 thermometer with remote fieldhousing containing a iTEMP TMT82 HART transmitter and display for applications with limited access
1-/2-channel transmitter bundle with 4-wire field meter
RIA46 field meter and up to two Liquiline Compact CM82 transmitters with optional Bluetooth connection for field installation in all industries
SWAS Compact: reliable monitoring of steam/water cycles
Compact, ready-to-use solution for accurate monitoring of feed water quality during steam generation
iTHERM TrustSens self-calibration Monitoring
Automated temperature measurement solution – 100% compliance, 0% effort
iTHERM TrustSens Bluetooth and WirelessHART integration
Comfortable temperature measurement solution – 100% compliance, 0% effort
Free chlorine process water panel
Ready-to-use panel bundle for reliable and precise monitoring of disinfection processes
Low-turbidity measuring point for drinking and process water
All you need for reliable and highly accurate turbidity measurement
1-/2-channel transmitter bundle with 4-wire field meter
RIA46 field meter and up to two Liquiline Compact CM72 transmitters for field installation in all industries
TT511 Barstock thermowell Vanstone design
Metric thermowell for applications in the oil & gas industry
-
Measuring principle
Bar stock Thermowell
-
Characteristic / Application
metric style
Vanstone type
with collar flange -
Head connection
thread:
1/2″ NPT
without connection -
Maximum standard immersion length
500 mm (19,69″)
-
Max. immersion length on request
500 mm (19,69″)
-
Process connection
Collar flange
1 1/2″ 150
1 1/2″ 300
1 1/2″ 400
1 1/2″ 600
1 1/2″ 900
1 1/2″ 1500
2″ 150
2″ 300
2″ 400
2″ 600
2″ 900
2″ 1500
2″ 2500
DN25 PN40
DN25 PN100
DN50 PN40
DN50 PN63
DN50 PN100
DN80 PN40 -
Thermowell root diameter
30 mm (1,18″)
20 mm (0,79″) -
Medium contact material
1.4401 (316)
1.4571 (316Ti)
Alloy400
Alloy625
A182 F51
A182 F55 -
Wetted part finishing (Ra)
<= 1,6 µm (63.00µin)
<= 0,8 µm (31.50 µin) or roughened to Ra=6 (0.24µm) -
Tip shape
conical or tapered
-
Temperature range
-200…700°C (-328…1.292 °F)
-
Max. process pressure (static)
depending on process connection up to 2500 lbs
-
Max. process pressure at 400 °C
depends on process connection
Field of application
It is a specially designed thermowell for thermometer installation. The thermowell shaft and the process connection flange are not interconnected. For installation, the collar of the thermowell is fitted between two flanges; on the one hand it is fitted onto the thermowell and on the other hand it is bolted to the connection nozzle on the process side. Many different flange versions are available to secure the unit to the permanently installed nozzle flange. It is machined from solid bar stock.
The thermowell will be used in applications with high process requirements. The predominant industries are Oil & Gas and Petrochemical. The process connection flange is not welded on the thermowell stem but designed as collar flange. This special Vanstone thermowell design enables a wide variety of applications and is suitable for resistance and thermocouple thermometers.
Benefits
Solid thermowell, made of drilled bar stock material.Fulfillment of various, industry specific requirements with a standard product. Flexible selection of immersion length and thermowell geometry according to the process specifications. In accordance with Shell specification: S.38.113 rev.D and S.38.114 rev.DExact thermowell stress calculation ensuring safe plant operation. Vanstone design with outstanding cost effectiveness:Reuse of the flange if the thermowell has to be replaced, flexible selection of the flange material as well as reduced spare parts and storing concept.
iTHERM ModuLine TT411 Welded thermowell
Metric thermowell for hygienic and aseptic applications in the food & beverages and pharmaceutical industries
-
Measuring principle
Fabricated Thermowell
-
Characteristic / Application
metric style
hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
hygienic process connections
QuickNeck for easy and cost saving recalibration -
Head connection
QuickNeck
male thread:
M24x1,5
G3/8″ -
Maximum standard immersion length
4.000 mm (157,48″)
-
Max. immersion length on request
Not defined
-
Process connection
compression fitting
weld in adaptor
clamp connections acc. to ISO2852
screwed pipe joint acc. to DIN 11851
aseptic screwed pipe joint acc. to DIN 11864-1
metallic sealing system
thread acc. to ISO 228 for liquiphant adaptor APV Inline
Varivent
Ingold
SMS 1147
Neumo Biocontrol
Tee and elbow thermowells DIN11865 -
Thermowell root diameter
6,0 mm (0,24″)
9,0 mm (0,35″)
12,7 mm (0,5″) -
Medium contact material
1.4435 delta-ferrit < 1%
316L -
Wetted part finishing (Ra)
< 0,76 μm (29,92 μin)
< 0,38 μm (14,96 μin)
< 0,38 μm (14,96 μin) electropolished -
Tip shape
straight
reduced
tappered -
Temperature range
-200…650 °C (-328…1.202 °F)
-
Max. process pressure (static)
40 bar (580 psi)
-
Max. process pressure at 400 °C
depends on process connection
Field of application
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industriesPressure range up to 40 bar (580 psi)For increased protection requirements of the temperature sensor regarding physical and chemical effectsFor use in pipes and containers or tanksIdeally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes
Benefits
iTHERM QuickNeck – cost and time savings thanks to simple, tool-freerecalibration of the insert usedOver 50 hygienic process connectionsGlobal portfolio with metric and imperial versionsInternational certification: hygiene standards as per 3-A®, EHEDG, ASME BPE,FDA, TSE Certificate of SuitabilityOptional: 1.4435 material, delta ferrite content < 1%Fast response time owing to reduced tips with thin wallsState of the art Tee and Elbow elements, without welds and dead legs and with best in class hygienic design
iTHERM ModuLine TT131 Welded thermowell
Metric thermowell for a wide range of industrial applications
-
Measuring principle
Fabricated Thermowell
-
Characteristic / Application
metric style
according to DIN 43772
process connection threaded, flanged, compression fitting
with neck -
Head connection
external thread:
M24 x 1.5, 1/2″ NPT, G1/2
Female thread:
M20 x 1.5, 1/2″ NPT, G1/2
QuickNeck -
Maximum standard immersion length
4.500 mm (177″)
-
Max. immersion length on request
4.500 mm (177″)
-
Process connection
Thread:
G3/8″, G1/2″, G3/4″, G1″
NPT1/2″, NPT3/4″, NPT 1″
M18x1.5, M20x1.5, M27x2, M33x2
R1/2″, R3/4″
Cap-nut:
M20x1.5, G1/2″, G3/4″
Compression fitting:
NPT1/2″, G1/2″, G1″
Flansche:
DN15 PN40 B1, C
DN25 PN20, PN40, PN100 B1, B2, C
DN40 PN40 B1
DN50 PN40 B1
ASME 1″ 150 RF
ASME 1″ 300 RF
ASME 1 1/2″ 150 RF
ASME 2″ 150 RF
ASME 2″ 300 RF -
Thermowell root diameter
9×1,25 mm
11×2 mm
12×2,5 mm
14×2 mm
16×3,5 mm
1/4″ SCH80
1/2″ SCH80
1/2″ SCH40 -
Medium contact material
316 (1.4401)
316L (1.4404)
316Ti (1.4571)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
Alloy 446 (1.4749)
Alloy 321 (1.4541)
Sheath PTFE
Sheath Tantal -
Wetted part finishing (Ra)
< 1.6 μm (63.00 μin)
-
Tip shape
straight
reduced
tapered
optimized for quick response times -
Temperature range
-200…1.100 °C (-328…2.012 °F)
-
Max. process pressure (static)
Depending on configuration up to 100 bar
-
Max. process pressure at 400 °C
Depending on configuration
Field of application
This thermowell designed according to DIN 43772 guarantees a high resistance to most industrial process environments. It is made from pipe or tube and is available in a wide range of diameters and materials. A specially designed thermowell tip ensures fast response times for a more efficient process control. Oversheaths in PTFE or tantalum can withstand extremely corrosive process conditions. It is offered with a variety of process connections: flanges, threads, weld-in or compression fittings.
Protects the temperature sensor against physical and chemical stressHigh robustness for challenging process conditionsPressure range: up to 100 bar (1450 psi)For use in pipes, containers or tanksImproved ease of maintenance (sensor replacement without process shutdown) and recalibration of the measuring point
Benefits
Modular configuration according to DIN 43772iTHERM QuickNeck: cost and time savings thanks to simple, tool-free recalibration of the insert Extension, immersion length and total length can be chosen according to process requirements Wide choice of dimensions, materials and process connections available Specially designed tip for fast response times
iTHERM ModuLine TST434B RTD thermometer
Modular resistance thermometer for outdoor or indoor ambient temperature measurement
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
probe for ambient temperature measurement
without neck -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Outer diameter protection tube / Insert
20,0 mm (0,79”)
-
Material protection tube/ thermowell
Aluminium
-
Operating temperature range
PT 100:
-50 °C …150 °C
(-58 °F …302 °F) -
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
-
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Certification
SIL (transmitter only)
Field of application
The iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring the room temperature in almost all industries.It is available as a complete unit including Endress+Hauser temperature transmitters for enhanced measurement accuracy and reliability compared to directly wired sensors. With a variety of common and advanced outputs and communication protocols, they offer easy customizing.
Outdoor or indoor ambient temperature measurement Maximum measuring range: –50 to +150 °C (–58 to +302 °F) Degree of protection: IP66/68 (NEMA Type 4x encl.)
Benefits
Robust terminal heads according to DIN EN 50446 or stable plastic housings offer optimal protection from extreme ambient conditionsReliable, long term stable and accurate indoor or outdoor ambient temperature measurementSimple and fast wall mountingOptional head transmitters: Analog 4 to 20 mA, HART®, PROFIBUS® PA, FOUNDATION Fieldbus™, IO-Link, PROFINET® over Ethernet-APL/SPE
TST310 RTD thermometer, temperature cable probe
Cost efficient Pt100 sensor for use in many process and laboratory applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
cable probe
suitable for hazardous areas
process connection as compression fitting -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
3,0 mm (0,12”)
6,0 mm (0,24”) -
Max. immersion length on request
up to 10.000,00 mm (393,70”)
-
Material protection tube/ thermowell
1.4404 (316L)
1.4571 (316Ti) -
Process connection
male thread:
G1/4″
G1/2″
M10x1
M8x1
compression fitting:
G1/8″
G1/4″
G1/2″
NPT1/4″
NPT1/2″
M10x1
M8x1 -
Tip shape
straight
-
Operating temperature range
PT 100:
-50 °C …400 °C
(-58 °F …752 °F) -
Max. process pressure (static)
at 20°C: up to 75 bar (depending on the process connection)
-
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
t50 = 3 s
t90 = 6 s -
Integration head transmitter
no
-
Ex – approvals
ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
ATEX II1G Ex ia IIC T6
ATEX II 3 G Ex nA IIC T6, II3D
NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
EAC Ex ia
UK II1G Ex ia IIC T6 Ga
UK II1/2D Ex ia IIIC Da/Db, II1G Ex ia IIC T6 Ga
UK II1D Ex ia IIIC Da, II1G Ex ia IIC T6 Ga
UK II 3 G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc
IECEx Ex ia IIC T6 Ga
NEPSI Ex nA IIC T6
Field of application
The RTD cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid medium like air, water, oil, etc. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.
The resistance thermometer is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid media like air, water, oil and others.
Benefits
High flexibility through user-specific insertion lengths and variable process connectionsFast response timeSingle or double Pt100 sensor of accuracy class A, B, or AA as per IEC 60751Types of protection for use in hazardous locations: Intrinsic safety (Ex ia) and non-sparking (Ex nA) Marine approval
iTEMP TMT86 head transmitter with Ethernet-APL
Ethernet-APL head temperature transmitter for the use in hazardous areas
-
Measuring principle
Head transmitter
-
Input
2 x RTD, TC, Ohm, mV
-
Output
PROFINET
-
Auxiliary power supply
9,6…15 V DC (Ethernet-APL)
20…30 V DC (SPE) -
Communication
PROFINET with Ethernet-APL
-
Installation
Terminal head form B / in field
-
Accuracy
(Pt100, -50…200 °C) <= 0,1 K
(Pt100, -58…392 °F) <= 0,18 °F -
Galvanic isolation
yes
-
Certification
ATEX II1G Ex ia IIC T6
ATEX II3G Ex ic IIC T6 Gc
ATEX II3D Ex tc IIIC Dc
ATEX II2G Ex ia IIC T6, II3D Ex ia IIIC Dc
ATEX II3G Ex ec IIC T6, II3D
ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
CSA C/US General Purpose
CSA C/US IS I/1/A-D, AEx/Ex ia IIC, NI I/2/A-D, AEx/Ex ec IIC Gc
CSA XP, NI, DIP I, II, III/1+2/A-G
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
IECEx Ex d T6 Gb, Ex tb IIIC Db
KC Ex ia IIC T6 Ga
KC Ex db IIC T6 Gb
INMETRO Ex ia IIC T6 Ga
INMETRO Ex d T6 Gb, Ex tb IIIC Db
NEPSI Ex ia IIC T4/T5/T6
NEPSI Ex d IIC T6 Gb
UK Ex ia IIC T6 Ga
UK Ex d IIC T6 Gb
ATEX IECEx II1G Ex ia IIC T6 Ga
ATEX IECEx II2D Ex tb IIIC Db
Field of application
The iTEMP TMT86 is a reliable, intelligent and future proof dual-channel Ethernet-APL PROFINET temperature head transmitter for thermometers with terminal head form B and is suitable for use in hazardous areas. Beneficial diagnostic functions like corrosion monitoring of the sensor wires help to improve the plant up-time. The embedded webserver and the up-to-date FDI package simplifies the device configuration and integration.
Ethernet-APL: 2-wire Ethernet IEEE 802.3cg 10BASE-T1LTemperature measurement with two independent universal inputs (RTD, Ω, TC, mV)System integration with PROFINET®Installation in terminal head form B (flat face) as per DIN EN 50446Optional: installation in field housing for Ex d applicationsReliability, long-term stability, high precision and advanced diagnostic function in critical processes
Benefits
Digital communication down to the field level, even in explosive atmospheresEasy and standardized system integration via PROFINET® Profile 4Integrated web server offers simplicity during commissioning and maintenanceHigh accuracy of measuring point through sensor-transmitter matchingReliable operation with sensor monitoring and device hardware fault recognitionFast and tool-free wiring thanks to push-in terminal technology, optionalAttachable measured value display, optional
iTEMP TMT71 Temperature transmitter
Transformation of sensor signals into stable and standardized output signals for all industries
-
Measuring principle
Head transmitter
-
Input
1 x RTD, TC, Ohm, mV
-
Output
1 x analog 4…20 mA
-
Auxiliary power supply
10…36 V DC (Head transmitter)
11…36 V DC (DIN rail device)
10/11…30 V DC (Ex ia) -
Communication
pc-programmable
Bluetooth® wireless technology -
Installation
Terminal head form B / DIN rail / field mount housing
-
Accuracy
(Pt100, -50…200 °C) <= 0,1 K
(Pt100, -58…392 °F) <= 0,18 °F -
Galvanic isolation
yes
-
Certification
ATEX II1G Ex ia IIC T6
ATEX II3G Ex ic IIC T6 Gc
ATEX II3D Ex tc IIIC Dc
ATEX II3G Ex nA IIC T6 Gc
ATEX II2G Ex ia IIC T6 Gb, II3D
ATEX II3G Ex nA IIC T6 Gc, II3D
ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
CSA C/US General Purpose
CSA C/US IS, Ex ec I/1+2/A-D
CSA C/US XP, DIP I, II, III/1+2/A-G
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
IECEx Ex nA IIC T6 Gc
IECEx Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex ia IIC T6 Ga
INMETRO Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex nA IIC T6 Gc
NEPSI Ex ia IIC T6 Ga
NEPSI Ex d IIC T6 Gb
NEPSI Ex nA II T6 Gc
UK II1G Ex ia IIC T6 Ga
UK II3D Ex tc IIIC Dc
UK II2G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
ATEX IECEx II1G Ex ia IIC T6 Ga
ATEX IECEx II2D Ex tb IIIC Db
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals. The standardized 4 to 20 mA output signal is used for process measurement. Swift and easy commissioning, operation and maintenance via PC software or with integrated Bluetooth® technology and Endress+Hauser SmartBlue App.
Bluetooth®-enabled or PC programmable temperature transmitter for the conversion of various input signals into a scalable, analog 4 to 20 mA output signalImproved process efficiency and increased plant uptimeUniversal input for resistance thermometers (RTD), thermocouples (TC), resistance transmitters (Ω) and voltage transmitters (mV)Installation in terminal head form B as per DIN EN 50446Installation in cabinets with DIN rail housingOptional installation in field housing for Ex d applications
Benefits
Safe operation in hazardous areas thanks to international approvals Reliable operation thanks to sensor and device monitoring Integrated Bluetooth® interface for the wireless display of measured values and configuration via Endress+Hauser SmartBlue App, optionalUser-friendly guided user interface concept also on-site via Bluetooth® Available with plug-on display TID10 Diagnostics information according to NAMUR NE 107
iTEMP TMT36 IO-Link temperature head transmitter
Accurate and reliable process temperature measurement for one RTD sensor with integrated IO-Link function
-
Measuring principle
Head transmitter
-
Input
1 x RTD
-
Output
1 x IO-Link
-
Auxiliary power supply
18…30 V DC
-
Communication
IO-Link
-
Installation
Terminal head form B
-
Accuracy
(Pt100, -50…200 °C) <= 0,15 K
(Pt100, -58…392 °F) <= 0,15 K -
Galvanic isolation
no
-
Certification
CSA General Purpose
Field of application
The iTEMP TMT36 is a reliable, long lasting, single-channel IO-Link temperature head transmitter with a form B connection head. Individual transmitter-sensor matching with Callendar van Dusen linearization further improves the temperature measurement accuracy of RTD sensors. The IO-Link capable iTEMP TMT36 can be installed in all modular Endress+Hauser thermometers to digitize a larger number of applications with special requirements using IO-Link technology.
The temperature transmitter is characterized by its reliability, long-term stability, high precision and diagnostic functionsFor maximum safety and availabilityInstallation in terminal head form B (flat face), or on DIN rail with DIN rail clipIO-Link (1x PNP, NPN or push-pull switch output, configurable)
Benefits
Push-in terminals for fast, tool-free wiring during installation or maintenanceSimple parametrization via free software tools (requires SFP20)Transmitter-sensor matching using Callendar van Dusen linearization for critical measurement pointsImproved RTD measurement accuracy up to 0.15 K and long-term stabilitySafe and reliable operationIO-Link technology to digitize the the last mile of your plant
iTEMP TMT31 head mount temperature transmitter
Accurate and reliable process temperature measurements for RTD sensors
-
Measuring principle
Head transmitter
-
Input
1x Pt100 / Pt1000
-
Output
1 x analog 4…20 mA
-
Auxiliary power supply
10…36 V DC
-
Communication
pc-programmable
-
Installation
Terminal head form B
-
Accuracy
(Pt100,Pt1000, -50…+250°C) <= 0,1 K
(Pt100,Pt1000, -58…+482°F) <= 0,18° F -
Galvanic isolation
no
-
Certification
ATEX II3G Ex ec IIC Gc
CSA C/US General Purpose
CSA C/US NI Cl.I Div.2 Gr.A-D,Ex ec IIC Gc
ATEX II3G Ex ec IIC Gc + CSA C/US Ex ec IIC Gc
DNV (GL) marine approval
Field of application
The iTEMP TMT31 is a reliable, long-term stable, single-channel 4 to 20 mA temperature transmitter for thermometers with terminal head Form B suited for use in Zone 2 / Div. 2 areas. Individual transmitter-sensor matching with Callendar-Van Dusen linearization further improves your temperature measurement accuracy for RTD sensors. Push-in terminals for quick wiring facilitate installation. The device is available pre-configured or can easily be parametrized using free software tools.
Highly accurate and reliable temperature measurement for various industrial and hygienic process applicationsCertified for use in Zone 2 (Ex ec) / Div. 2 areasInput: Single RTD sensor input for Pt100 or Pt1000 (2-/3- or 4-wire) sensorsOutput: 4 to 20 mA analog outputConfigurable or factory-set fixed parameters Installation in terminal heads Form B as per DIN EN 50446
Benefits
Push-in terminals for fast, tool-free wiring during installation or maintenanceSimple parametrization via free software tools (requires FXA291 or TXU10)Transmitter-sensor matching using Callendar-Van Dusen linearization for critical measurement pointsImproved RTD measurement accuracy up to 0.1 K and long-term stabilityDiagnostics information according to NAMUR NE 107Ready-to-use: Factory pre-configured
iTEMP TMT142B HART® 7 temperature transmitter
Smart, rugged, innovative: New generation temperature field transmitter with Bluetooth®
iTHERM MultiSens Bundle TMS31 Multipoint RTD/TC thermometer
Flexible metal rope multipoint for silos and storage tank applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
imperial style
easy-to-use
suitable for hazardous areas
process connection: flanged
Storage applications
linear sensor distribution
modular design -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
25 mm
37 mm -
Max. immersion length on request
up to 60.000,00 mm (2.360”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4435 (316L) -
Process connection
flange:
1 1/2″ ASME/ANSI B16.5 150
…300
2″ ASME/ANSI B16.5 150
…300
3″ ASME/ANSI B16.5 150
..300
4″ASME/ANSI B16.5 150
..300
DN40 EN/DIN 1092.1 PN16
…PN40
DN50 EN/DIN 1092.1 PN16
…PN40
DN80 EN/DIN 1092.1 PN16
…PN40
DN100 EN/DIN 1092.1 PN16
…PN40 -
Tip shape
straight
-
Operating temperature range
Type K:
max. 800 °C
(max. 1.472 °F)
Type J:
max. 520 °C
(max. 968 °F)
Pt100 WW:
-200…600 °C
(-328…1.112 °F)
Pt100 StrongSens:
-50…500 °C
(-58…932 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F) -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Accuracy
class 1 acc. to IEC 60584
class 2 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA -
Response time
TC
t50 = 1 s
t90 = 2 s
RTD
t50 = 3 s
t90 = 6 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX
IECEX
UL
FM
CSA -
Certification
SIL (transmitter only)
Field of application
The iTHERM TMS31 is a versatile, modular multipoint temperature assembly designed for temperature average detection and profiling in grain, organic bulk material storage silos and in oil, fuel storage tanks.The device’s mechanical robustness and accurate temperature sensors offer the necessary characteristics for safe, reliable and economic product storage operations. In its standard configuration it is available with up to 20 thermocouple (TC) or RTD sensors fitted to a primary metal rope.
Oil storage tanksBulk material silos
Benefits
Easy installation and process integration thanks to a high degree of customization Flexible rope that adapts to different silos or tank operating conditions (filling, emptying, storage, …) Intrinsically safe device for use in Ex areas Highly robust design for a long product lifetime and continuous monitoring in all conditions
iTHERM TrustSens TM372 Self-calibrating temperature sensor
100% compliance, 0% effort Hygienic compact RTD thermometer, US style
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
self-calibrating
imperial style
compact temperature probe
hygienic design
hygienic process connection -
Thermowell / protection tube
without
incl. thermowell
incl. Tee-/elbow thermowell -
Insert / probe
pipe version, isolated wires, not flexible
-
Outer diameter protection tube / Insert
1/4” (6,35 mm)
3/8” (9,53 mm)
1/2″ (12,7 mm) -
Max. immersion length on request
up to 28” (711 mm)
others on request -
Material protection tube/ thermowell
316L
-
Process connection
Weld-in adapter
Tri-clamp
Clamp-connections according to ISO2852
G3/4″ Liquiphant
G1″ Liquiphant
Varivent
T- and elbow thermowell -
Tip shape
straight
reduced -
Surface roughness Ra
30 μin (0,76 μm)
15 μin (0,38 μm )
15 μin (0,38 μm ) electropolished -
Operating temperature range
PT 100:
-40 °C …160 °C (-40 °F …320 °F),
optional up to 190 °C (374 °F) -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Response time
t50 = 2,5 s
t90 =9,5s -
Integration head transmitter
no (4…20mA Signal)
-
Ex – approvals
CSA C/US IS, I/1+2/A-F
Field of application
The award-winning smart temperature probe with integrated HART® transmitter and Heartbeat Technology features the world’s first RTD sensor unit capable of fully automated in-situ self-calibration. It effectively eliminates the risk of undetected non-conformities, reduces production downtime and increases product safety and process efficiency in applications of the food & beverage and life sciences industries. The device is fully compliant to FDA 21 CFR Part 11 regulations and GMP rules.
Specially designed for use in hygienic and aseptic applications in the food & beverage and life sciences industriesMeasuring range: –40 to 190 °C (–40 to 374 °F)Pressure range up to 50 bar (725 psi)Protection class: IP65/67 or IP69 Communication: Analog output 4 to 20 mA, HART® protocol
Benefits
Risk and cost reduction thanks to self-calibration and Heartbeat TechnologyNo production downtime due to an automated and fully traceable inline self-calibrationAutomatized documentation, memory for 350 calibration points.
Printable calibration certificate – audit proof.Automated 4 to 20 mA loop check for saving time and increasing safety in your process. See how iTHERM TrustSens can perform a fully automated loop check in five easy steps. The video shows the device set up and benefits for your process.Elimination of non-conformities or undetected failures International certifications and approvals:– EHEDG, ASME BPE, FDA, 3-A, 1935/2004, 2023/2006, 10/2011, CE CRN, CSA General Purpose, Explosion protection, e.g. ATEX/IECExHighest accuracy of measuring point through sensor-transmitter matching
iTHERM ModuLine TM121
Thermometer with RTD or TC insert complete with manufactured thermowell produced from pipe material
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly
universal range of application
with neck
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
welded protection tube or to be used with thermowell
-
Insert / probe
Basis Sensortechnologie
-
Outer diameter protection tube / Insert
Thermowell:
9×1,25 mm
11×2 mm -
Max. immersion length on request
up to 1.000,0 mm (39”)
-
Material protection tube/ thermowell
316L (1.4404)
-
Process connection
Thread:
G1/2″
NPT1/2″
M20x1.5, M27x2, M33x2
Compression fitting:
NPT1/2″, G1/2″, G1″
Flansche:
DN25 DN40 B1
ASME 1″ 150 RF
ASME 1″ 300 RF
ASME 1 1/2″ 150 RF
ASME 2″ 150 RF
ASME 2″ 300 RF -
Tip shape
straight
-
Operating temperature range
Basic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F) -
Max. process pressure (static)
depending on the configuration
-
Accuracy
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2 -
Response time
t90 around 100 s
depending on configuration -
Integration head transmitter
yes (4 … 20 mA; HART)
Field of application
RTD or TC assembly characterized by basic sensor technology, application in non-hazardous areas, standard extension neck, low-cost unit. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.
Universal range of applicationApplication in non-hazardous areasMeasuring range: –50 to +650 °C (–58 to +1202 °F)Pressure range up to 50 bar (725 psi)Degree of protection: up to IP 68
Benefits
Economical, reliable measurementUser-friendly from product selection to maintenance Wide range of process connectionsEasy and safe device setup and service using Bluetooth® communication
iTHERM ModuLine TM101
RTD or thermocouple temperature probe for direct installation without thermowell in various industrial applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
Basic technologie
metric style
universal range of application
direct process contact -
Thermowell / protection tube
without, direct process contact
-
Insert / probe
Basis Sensortechnologie
-
Outer diameter protection tube / Insert
Insert:
6,0 mm -
Max. immersion length on request
up to 1.000,0 mm (39”)
-
Material protection tube/ thermowell
Insert Material:
316L (1.4404)
Alloy 600 (2.4816) -
Process connection
Thread:
G1/2″, G1/4″
NPT1/2″
M18x1.5, M20x1.5
Cap-nut:
G1/2″, G3/4″
Compression fitting, also spring load:
NPT1/2″, G1/2″ -
Tip shape
straight
-
Operating temperature range
Basic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F) -
Max. process pressure (static)
depending on the configuration
-
Accuracy
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2 -
Response time
t90 around 17 s
depending on configuration -
Integration head transmitter
yes (4 … 20 mA; HART)
Field of application
Basic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert for use in non-hazardous areas. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.
Wide range of applicationsMeasuring range: -50 to +650 °C (-58 to +1202 °F)Pressure range: up to 50 bar (725 psi)Protection class: up to IP68For use in non-hazardous areas
Benefits
Excellent value for money and fast global deliveryUser-friendly product selection, smart design for easy maintenanceWide range of process connectionsBluetooth® connectivity (optional)
TH14 Modular RTD thermometer, US style
Best in class temperature measurement technology for general applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
US style
modular temperature assembly
flanged process connection
with extension
incl. thermowell -
Thermowell / protection tube
bar stock (drilled)
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
3/4” (19,05 mm)
17/16” (26,99 mm)
22,23 mm … 26,99 mm
(0,88” … 1,06”) -
Max. immersion length on request
up to 24″ (609 mm)
others on request -
Material protection tube/ thermowell
316/316L
others on request -
Optional coating
available on request
-
Process connection
flange:
ASME 1″ 150 RF (B16.5)
ASME 1″ 300 RF (B16.5)
ASME 1″ 600 RF (B16.5)
ASME 1″ 900/1500 RF (B16.5)
ASME 1.5″ 150 RF (B16.5)
ASME 1.5″ 300 RF (B16.5)
ASME 1.5″ 600 RF (B16.5)
ASME 1.5″ 900/1500 RF (B16.5)
ASME 2″ 150 RF (B16.5)
ASME 2″ 300 RF (B16.5)
ASME 2″ 600 RF (B16.5)
ASME 2″ 900/1500 RF (B16.5)
ASME 3″ 150 RF (B16.5)
ASME 3″ 300 RF (B16.5)
ASME 3″ 600 RF (B16.5)
ASME 3″ 900/1500 RF (B16.5) -
Tip shape
straight
tapered -
Surface roughness Ra
32 μin (0.80 μm)
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
depends on configuration -
Accuracy
class AA acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
transmitter only
FM IS
CSA IS
FM/CSA IS -
Certification
SIL (transmitter only)
Field of application
The high modular thermometer is used for several applications with harsh environments, e.g. in power plants, refineries or in the chemical or petrochemical industry. The robust device with barstock thermowell and flange connection in SS316 or INCONEL600 and different head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability.
The TH14 temperature sensors are RTD assemblies installed in thermowells and designed for use in all types of process industries, including harsh environments, due to their rugged design. They are made up of a measurement probe with an insulated RTD element, sheath and a thermowell made of barstock material.The sensor assemblies can be used in process industries such as:ChemicalsPetrochemical Power plantsRefineriesOffshore platforms
Benefits
High flexibility due to modular assembly with standard terminal heads and customized immersion lengthOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications. Remove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solutionAll iTEMP® transmitters provide long term stability ≤ 0.05 % per yearFast response time with reduced/tapered tip formHead transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™
TAF12T High temperature TC thermometer
Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
modular temperature assembly
high temperature (furnace)
ncl. triple ceramic thermowell -
Thermowell / protection tube
ceramic protection tube and 2x inner tube
-
Insert / probe
ceramic capilarry, rigid
-
Outer diameter protection tube / Insert
24,0 mm (0,94″)
26,0 mm (1,02″) -
Max. immersion length on request
up to 3.500,00 mm (137,80”)
-
Material protection tube/ thermowell
Ceramic (C530/C610/C799)
-
Process connection
compression fitting:
G11/2″ -
Tip shape
straight
-
Operating temperature range
Type S:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type R:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type B:
600 °C …1.700 °C
(1.112 °F …3.092 °F) -
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
-
Accuracy
class 2 acc. to IEC 60584
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Certification
SIL (transmitter only)
Field of application
Measuring points with extremely high process temperatures require these thermometers with ceramic thermowells and special metal thermocouples, such as platinum and rhodium. The thermowell as well as the intermediate and internal sheath of ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
The TAF12T are assemblies with triple ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.Process temperatures: up to +1700 °C (+3092 °F)
Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistanceLong term stable measurement due to sensor protection with non-porous materialsFlexible product selection by modular designOptimized life cycle costs by means of replaceable spare parts
TAF12D High temperature TC thermometer
Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
modular temperature assembly
high temperature probe (furnace)
incl. double ceramic thermowell -
Thermowell / protection tube
ceramic protection tube and inner tube
-
Insert / probe
ceramic capilarry, rigid
-
Outer diameter protection tube / Insert
14,0 mm (0,55″)
15,0 mm (0,59″) -
Max. immersion length on request
up to 3.500,00 mm (137,80”)
-
Material protection tube/ thermowell
Ceramic (C610/C799)
-
Process connection
compression fitting:
G3/4″
G1″
G11/2″
adjustable Flange -
Tip shape
straight
-
Operating temperature range
Type S:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type R:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type B:
600 °C …1.700 °C
(1.112 °F …3.092 °F) -
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
-
Accuracy
class 2 acc. to IEC 60584
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Certification
SIL (transmitter only)
Field of application
Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
The TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.Process temperatures: up to +1700 °C (+3092 °F)
Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance Long term stable measurement due to sensor protection with non-porous materialsFlexible product selection by modular designOptimized life cycle costs by means of replaceable spare parts
TAF11 High temperature TC thermometer
Applicable for steel treatment (annealing), concrete furnaces and primaries
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
modular temperature assembly
high temperature probe (furnace)
incl. single ceramic thermowell -
Thermowell / protection tube
ceramic protection tube
-
Insert / probe
ceramic capilarry, rigid
-
Outer diameter protection tube / Insert
14,0 mm (0,55″)
16,0 mm (0,59″)
17,0 mm (0,68″)
22,0 mm (0,87″)
24,0 mm (0,94″)
26,6 mm (1,05″) -
Max. immersion length on request
up to 4.000,00 mm (157,48”)
-
Material protection tube/ thermowell
Ceramic (C610)
silicon nitride ceramic (SiN)
sintered silicon carbide (SiC) -
Process connection
compression fitting:
G3/4″
G1″
G11/2″
adjustable Flange -
Tip shape
straight
-
Operating temperature range
Type K:
-40 °C …1.300 °C
(-40 °F …2.372 °F)
Type J:
-40 °C …750 °C
(-40 °F …1.382 °F)
Type N:
-40 °C …1.150 °C
(-40 °F …2102 °F)
Type S:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type R:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type B:
600 °C …1.600 °C
(1.112 °F …2.912 °F) -
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
-
Accuracy
class 2 acc. to IEC 60584
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Certification
SIL (transmitter only)
Field of application
Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell made from special materials serves as protection from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
Applicable for steel treatment (annealing), concrete furnaces and primaries. It contains a single or double TC insert and a ceramic protection tube.Process temperatures: up to +1600 °C (+2912 °F)
Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistanceLong term stable measurement due to sensor protection with non-porous materialsFlexible product selection by modular designOptimized life cycle costs by means of replaceable spare parts
T14 Explosion proof Pt100 thermometer, US style
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
Explosion Proof US style
modular temperature assembly
for heavy duty applications
flanged process connection
with extension
incl. thermowell -
Thermowell / protection tube
bar stock (drilled)
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
7/8” (22,23 mm)
17/16” (26,99 mm) -
Max. immersion length on request
up to 22.5″ (571 mm)
others on request -
Material protection tube/ thermowell
316/316L
others on request -
Optional coating
Available on request
-
Process connection
flange:
ASME 1″ 150 RF (B16.5)
ASME 1″ 300 RF (B16.5)
ASME 1″ 600 RF (B16.5)
ASME 1″ 900/1500 RF (B16.5)
ASME 1,5″ 150 RF (B16.5)
ASME 1,5″ 300 RF (B16.5)
ASME 1,5″ 600 RF (B16.5)
ASME 1,5″ 900/1500 RF (B16.5)
ASME 2″ 150 RF (B16.5)
ASME 2″ 300 RF (B16.5)
ASME 2″ 600 RF (B16.5)
ASME 2″ 900/1500 RF (B16.5) -
Tip shape
straight
tapered -
Surface roughness Ra
32 μin. (0.80 μm)
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
depends on configuration -
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
depending on configuration
63% rt = 20 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
FM XP DIP Class I,II,III Div. 1+2
FM XP NI DIP Class I,II,III Div. 1+2
CSA XP DIP Class I,II,III Div. 1+2
CSA XP NI DIP Class I,II,III Div. 1+2
FM/CSA XP DIP Class I,II,III Div. 1+2
FM/CSA XP NI DIP Class I,II,III Div.1+2
CSA C/US XP, DIP I, II, III/1/A-G
cCSAus General Purpose -
Certification
SIL (transmitter only)
Field of application
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. A optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.
The T14 temperature sensor is a RTD assembly installed in Thermowell and designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.The sensor is made up of a measurement probe with an insulated RTD element, sheath and a thermowell made of bar-stock material.
The sensor assembly can be used in process industries such as:
Chemicals
Petrochemical
Refineries
Offshore Platforms
Benefits
FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safetyOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applicationsRemove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solutionAll iTEMP transmitters provide long term stability ≤0.05% per year