Total phosphorus analyzer for environmental monitoring, industrial and municipal wastewater
Colorimetric system for monitoring of drinking water, mineral water or raw water for food production
Colorimetric system for monitoring of drinking water, mineral water and process water
Colorimetric system for the monitoring of industrial wastewater and optimization of process control
Colorimetric system for drinking water and wastewater monitoring and optimization of process control
Reliable online monitoring of industrial wastewater
iTHERM TM131 thermometer with remote fieldhousing containing a iTEMP TMT82 HART transmitter and display for applications with limited access
RIA46 field meter and up to two Liquiline Compact CM82 transmitters with optional Bluetooth connection for field installation in all
Compact, ready-to-use solution for accurate monitoring of feed water quality during steam generation
Automated temperature measurement solution - 100% compliance, 0% effort
Comfortable temperature measurement solution – 100% compliance, 0% effort
Ready-to-use panel bundle for reliable and precise monitoring of disinfection processes
All you need for reliable and highly accurate turbidity measurement
RIA46 field meter and up to two Liquiline Compact CM72 transmitters for field installation in all industries
Metric thermowell for applications in the oil & gas industry
Metric thermowell for hygienic and aseptic applications in the food & beverages and pharmaceutical industries
Metric thermowell for a wide range of industrial applications
Modular resistance thermometer for outdoor or indoor ambient temperature measurement
Cost efficient Pt100 sensor for use in many process and laboratory applications
Ethernet-APL head temperature transmitter for the use in hazardous areas
Transformation of sensor signals into stable and standardized output signals for all industries
Accurate and reliable process temperature measurement for one RTD sensor with integrated IO-Link function
Accurate and reliable process temperature measurements for RTD sensors
Smart, rugged, innovative: New generation temperature field transmitter with Bluetooth®
Flexible metal rope multipoint for silos and storage tank applications
100% compliance, 0% effort Hygienic compact RTD thermometer, US style
Thermometer with RTD or TC insert complete with manufactured thermowell produced from pipe material
RTD or thermocouple temperature probe for direct installation without thermowell in various industrial applications
Best in class temperature measurement technology for general applications
Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries
Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries
Applicable for steel treatment (annealing), concrete furnaces and primaries
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

TP analyzer Liquiline System CA80TP

Total phosphorus analyzer for environmental monitoring, industrial and municipal wastewater

  • Measuring principle

    Colorimetric

  • Characteristic

    Analyzer for total phosphorus

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39.2 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar

  • Sample flow rate

    Min. 30 ml/min

  • Consistency of the sample

    Low solid content (TS<50 mg/l), homogeneous

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    Self-priming analyzer with optical dosing unit l
    Dilution module (optional)
    Digital communication for remote access

  • Application

    Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
    Monitoring of the wastewater treatment plant outlet for documentation purposes
    Monitoring and optimization of activated sludge basins

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 measuring channel
    1 to 4 digitale sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0 to 2 mg/l
    0.05 to 10 mg/l
    0.5 to 50 mg/l

  • Consumables

    Reagents and standard solutions CY80TP are necessary for the operation

Field of application
Phosphorus is the decisive factor for excessive algae and plant growth in water bodies, that’s why continuous monitoring of this parameter is essential. The Liquiline System TP analyzer offers precise online measurement of total phosphorus and ensures highest process safety. Automatic calibration and cleaning save you operating costs while advanced diagnostics with remote access support you in providing process documentation to the authorities.

The Liquiline System TP analyzer monitors:
Inlet and outlet of wastewater treatment plants for documentation purposes and calculation of the cleaning capacity
Discharges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principle
Process water

Benefits
Molybdenum blue method according to EN ISO 6878:2004 guarantees direct comparability to laboratory results Meeting industry needs: The analyzer is perfectly suited for environmental monitoring, industrial and municipal wastewater Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications Safety on the highest level: Software-controlled safety cover for the reactor and all heated parts. Additional safety light barrier prevents overdosing of reagents and sample. Combination of reliable sample delivery and high-precision dosing: Peristaltic pumps are able to cope with particles in the sample. Light barriers enable precise, reproducible dosing. Enhanced reagent lifetime thanks to optional cooling moduleEasy upgrade of functionality to a complete measuring station – simply by adding modules and connecting Memosens sensors.

Nitrite analyzer Liquiline System CA80NO

Colorimetric system for monitoring of drinking water, mineral water or raw water for food production

  • Measuring principle

    Colorimetric

  • Characteristic

    Process analyzer for Nitrite in potable water

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar absolute

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    Optional cooling module for standard solution
    2 channel version optional
    User-definable measuring ranges
    Modular design for easily extensible functionality

  • Application

    Limit value monitoring of nitrite for potable water and mineral water applications

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Modbus RS485/TCP (optional)
    Ethernet (optional)
    Alarmrelay

  • Input

    1 or 2 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    10 to 500 µg/l NO2-N
    0.2 to 3.0 mg/l NO2-N
    0.1 to 1.0 mg/l NO2-N
    0.1 to 1.0 mg/l with dilution function to maximum 5 to 50 mg/l NO2-N

  • Consumables

    Reagents and standard solutions CY80NO as well as cleaner CY800 are necessary for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Field of application
Liquiline System CA80NO offers precise, regulation-compliant online measurement of nitrite. It supports you in meeting the specified limits in drinking water, mineral water or food production. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety.

Liquiline System CA80NO supports you in keeping the strict nitrite limits for: Drinking waterMineral waterRaw water for food production

Benefits
Compliance with standard colorimetric measuring principle – naphthylamine method – following ISO 6777 and DIN EN 26777 ensures comparability to lab measurements. Reduced operating costs through automatic calibration and cleaning. Simple maintenance: no tools required. Advanced diagnostics with remote access for increased process safety. Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation.Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors. Reduces installation effort.

Iron analyzer Liquiline System CA80FE

Colorimetric system for monitoring of drinking water, mineral water and process water

  • Measuring principle

    Colorimetric

  • Characteristic

    Process analyzer for iron in aqueous solutions
    Comply with standard colorimetric measuring principle, ferrozine method

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39.2 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Application

    Monitoring of the iron content of potable water, mineral water and source water for industrial processes

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 or 2 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0.05 to 2 mg/l Fe
    0.1 to 5 mg/l Fe
    0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe

  • Consumables

    Reagents and standard solutions CY80FE for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Field of application
Liquiline System CA80FE offers precise, regulation-compliant online measurement. It supports you in controlling the iron content of drinking water, mineral water or source water for industrial processes. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.

Liquiline System CA80FE monitors:Iron content in drinking water and mineral waterResidual iron after precipitation, flocculation and filtration processesProcess water containing diluted iron

Benefits
Compliance with standard ferrozine method ensures direct comparability to lab measurements Supports predictive maintenance by advanced diagnostics Reduced operating costs through automatic calibration and cleaning as well as low reagent consumption Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors. Comfortable remote access via integrated web server Seamless integration into process control systems thanks to digital field busses such as Modbus, PROFIBUS or EtherNet/IP

Chromate analyzer Liquiline System CA80CR

Colorimetric system for the monitoring of industrial wastewater and optimization of process control

  • Measuring principle

    Colorimetric

  • Characteristic

    Analyzer for Chromate (Chrome VI) in aqueous solutions

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar absolute

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    Optional cooling module for longer reagent shelf life
    2 channel version optional
    User-definable measuring ranges
    Modular design for easily extensible functionality
    Digital communication for remote access

  • Application

    Limit value monitoring of Chromate in potable water and waste water
    Common applications are industrial waste water Monitoring for tanneries and the galvanic industry

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Modbus RS485/TCP (optional)
    Ethernet (optional)
    Alarmrelay

  • Input

    1 or 2 measuring channels
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0,03 to 2.5 mg/l Cr(VI)
    0.2 to 5.0 mg/l Cr(VI)
    0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI)

  • Consumables

    Reagents and standard solutions CY80CR as well as cleaner CY800 are necessary for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Field of application
Liquiline System CA80CR offers highly accurate online measurement for optimized chromate removal in industrial wastewater. It supports you in achieving environmentally compliant electroplating and tanning processes. Like all Liquiline System analyzers, CA80CR enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning plus advanced diagnostics with remote access ensure consistent process safety.

Liquiline System CA80CR supports you in improving the environmental performance of your processes by:
Monitoring and optimizing the cleaning capacity of industrial wastewater treatment plants.Effluent monitoring in tanneries and electroplating plants.
Monitoring of membrane filtration.Limit monitoring in drinking water applications.

Benefits
Standardized colorimetric measuring principle – diphenyle carbazide method – guarantees compliance with discharge regulations. Reduced operating costs through automatic calibration and cleaning and low reagent consumption. Simple maintenance: no tools required. Advanced diagnostics with remote access for increased process safety. Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation. Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors. Reduces installation effort.

Aluminum analyzer Liquiline System CA80AL

Colorimetric system for drinking water and wastewater monitoring and optimization of process control

  • Measuring principle

    Colorimetric

  • Characteristic

    Process analyzer for aluminum in aqueous solutions
    Comply with standard colorimetric measuring principle – pyrocatechol violet methot

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 … 40 °C (39.2 … 104 °F)

  • Ambient temperature

    5 … 40C ( 41 … 104F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    at atmospheric pressure, < 0.2 bar

  • Sample flow rate

    min. 5ml/min (0,17 fl.oz/min)

  • Consistency of the sample

    low solid content (< 50NTU), aqueous homogeneous

  • Application

    Monitoring of the aluminum content of potable water, mineral water and industrial waste water

  • Power supply

    100 … 120 VAC / 200 … 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 oder 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 … 20 mA
    Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 or 2 measuring channel
    1 … 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    15 to 1000 µg/l Al
    15 to 1000 µg/l with dilution function to maximum 300 to 20 000 µg/l Al

  • Consumables

    Reagents and standard solutions CY80AL as well as cleaner CY800 are necessary for the operation. Regular maintenance is done with the parts of the maintenance kit CAV800.

Field of application
Liquiline System CA80AL offers precise, regulation-compliant online measurement of aluminum residues in drinking water and wastewater. The analyzer helps you to optimize aluminum dosing in flocculation processes and phosphate removal. It enables plug & play of up to 4 Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.

Liquiline System CA80AL aluminum analyzer supports:Limit monitoring in drinking waterOptimization of aluminum-based coagulation processesPhosphate elimination in wastewater treatment plants

Benefits
The aluminum analyzer uses the pyrocatechol violet method according to DIN ISO 10566, ensuring direct comparability to lab results
Supports predictive maintenance by advanced diagnostics Reduces operating costs thanks to automatic calibration and cleaning as well as low reagent consumption
Easy upgrade of functionality to a complete measuring station – by adding modules and connecting Memosens sensors. Comfortable remote access via integrated web serverSeamless integration into process control systems thanks to digital field buses such as Modbus, PROFIBUS, EtherNet/IP

High temperature TOC analyzer CA72TOC

Reliable online monitoring of industrial wastewater

  • Measuring principle

    UV photometric

  • Characteristic

    Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion

  • Size

    1558 x 785 x 400 mm
    61.3 x 30.9 x 15.8 inch

  • Design

    IP54

  • Process temperature

    0 to 40 °C (32 to 104 °F)

  • Ambient temperature

    5 to 35 °C (41 to 95 °F)

  • Process pressure

    Pressure free

  • Sample flow rate

    20 ml/min (0.32 US gal/hr)

  • Consistency of the sample

    Aqueous
    Flammable substances are not allowed in ignitable concentrations, in such cases a sample dilution is required

  • Specials

    Heatable Salt Trap
    Exchange furnace concept
    pH-controlled acid dosage with TIC stripping

  • Application

    Industrial wastewater monitoring
    Control of process wastewater
    Monitoring of industrial surface water
    Recording of the carbon load to control the nutrient dosage

  • Power supply

    115 VAC, 230 VAC, 50/60Hz

  • Output / communication

    0/4 to 20 mA, galvanically separated
    Two channel version has an addtional one
    RS 232 C, propietary, for data output and remote control (optional)

  • Input

    8 signal inputs 24 V DC, ative, load max. 500 Ohm

  • Measurement range

    0.25 to 600 mg TOC/l
    1 to 2400 mg TOC/l
    2.5 to 6000 mg TOC/l
    5 to 12000 mg TOC/l
    With the optional pre-dilution the measuring range will expand by the factor of 20

  • Consumables

    Stripp reagent, KHP or citric acid standard

Field of application
CA72TOC determines the total organic carbon (TOC) content in a number of industries. It measures reliably and accurately even in heavy duty applications with high loads of salt, fat or fibers. The reliable detection of product losses increases the process yield and saves money every day. Designed for long-term stability and highest availability, the CA72TOC offers maximum operational safety of your plant. Clear diagnostic messages actively support your predictive maintenance strategy.

CA72TOC monitors and controls: Industrial discharge
Inlets of wastewater treatment plants
Outlets of wastewater treatment plants
Process water
Surface run-off

Benefits
Process optimization: Constant safeguard against product losses. Cost savings: 2-channel version offers an excellent price-performance ratio.Reliable discharge monitoring: Configuration for fat and grease, low pH values and organic acids.Improved process stability and safety: Immediate readjustment of the process based on online information.Robust design: Self-cleaning slit filter and automatic backflush function support long maintenance intervals.Safe and convenient operation: Remote access and diagnostics via serial interface.

iTHERM applications with limited access

iTHERM TM131 thermometer with remote fieldhousing containing a iTEMP TMT82 HART transmitter and display for applications with limited access

1-/2-channel transmitter bundle with 4-wire field meter

RIA46 field meter and up to two Liquiline Compact CM82 transmitters with optional Bluetooth connection for field installation in all industries

iTHERM TrustSens self-calibration Monitoring

Automated temperature measurement solution – 100% compliance, 0% effort

iTHERM TrustSens Bluetooth and WirelessHART integration

Comfortable temperature measurement solution – 100% compliance, 0% effort

Free chlorine process water panel

Ready-to-use panel bundle for reliable and precise monitoring of disinfection processes

1-/2-channel transmitter bundle with 4-wire field meter

RIA46 field meter and up to two Liquiline Compact CM72 transmitters for field installation in all industries

TT511 Barstock thermowell Vanstone design

Metric thermowell for applications in the oil & gas industry

  • Measuring principle

    Bar stock Thermowell

  • Characteristic / Application

    metric style
    Vanstone type
    with collar flange

  • Head connection

    thread:
    1/2″ NPT
    without connection

  • Maximum standard immersion length

    500 mm (19,69″)

  • Max. immersion length on request

    500 mm (19,69″)

  • Process connection

    Collar flange
    1 1/2″ 150
    1 1/2″ 300
    1 1/2″ 400
    1 1/2″ 600
    1 1/2″ 900
    1 1/2″ 1500
    2″ 150
    2″ 300
    2″ 400
    2″ 600
    2″ 900
    2″ 1500
    2″ 2500
    DN25 PN40
    DN25 PN100
    DN50 PN40
    DN50 PN63
    DN50 PN100
    DN80 PN40

  • Thermowell root diameter

    30 mm (1,18″)
    20 mm (0,79″)

  • Medium contact material

    1.4401 (316)
    1.4571 (316Ti)
    Alloy400
    Alloy625
    A182 F51
    A182 F55

  • Wetted part finishing (Ra)

    <= 1,6 µm (63.00µin)
    <= 0,8 µm (31.50 µin) or roughened to Ra=6 (0.24µm)

  • Tip shape

    conical or tapered

  • Temperature range

    -200…700°C (-328…1.292 °F)

  • Max. process pressure (static)

    depending on process connection up to 2500 lbs

  • Max. process pressure at 400 °C

    depends on process connection

Field of application
It is a specially designed thermowell for thermometer installation. The thermowell shaft and the process connection flange are not interconnected. For installation, the collar of the thermowell is fitted between two flanges; on the one hand it is fitted onto the thermowell and on the other hand it is bolted to the connection nozzle on the process side. Many different flange versions are available to secure the unit to the permanently installed nozzle flange. It is machined from solid bar stock.

The thermowell will be used in applications with high process requirements. The predominant industries are Oil & Gas and Petrochemical. The process connection flange is not welded on the thermowell stem but designed as collar flange. This special Vanstone thermowell design enables a wide variety of applications and is suitable for resistance and thermocouple thermometers.

Benefits
Solid thermowell, made of drilled bar stock material.Fulfillment of various, industry specific requirements with a standard product. Flexible selection of immersion length and thermowell geometry according to the process specifications. In accordance with Shell specification: S.38.113 rev.D and S.38.114 rev.DExact thermowell stress calculation ensuring safe plant operation. Vanstone design with outstanding cost effectiveness:Reuse of the flange if the thermowell has to be replaced, flexible selection of the flange material as well as reduced spare parts and storing concept.

iTHERM ModuLine TT411 Welded thermowell

Metric thermowell for hygienic and aseptic applications in the food & beverages and pharmaceutical industries

  • Measuring principle

    Fabricated Thermowell

  • Characteristic / Application

    metric style
    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
    hygienic process connections
    QuickNeck for easy and cost saving recalibration

  • Head connection

    QuickNeck
    male thread:
    M24x1,5
    G3/8″

  • Maximum standard immersion length

    4.000 mm (157,48″)

  • Max. immersion length on request

    Not defined

  • Process connection

    compression fitting
    weld in adaptor
    clamp connections acc. to ISO2852
    screwed pipe joint acc. to DIN 11851
    aseptic screwed pipe joint acc. to DIN 11864-1
    metallic sealing system
    thread acc. to ISO 228 for liquiphant adaptor APV Inline
    Varivent
    Ingold
    SMS 1147
    Neumo Biocontrol
    Tee and elbow thermowells DIN11865

  • Thermowell root diameter

    6,0 mm (0,24″)
    9,0 mm (0,35″)
    12,7 mm (0,5″)

  • Medium contact material

    1.4435 delta-ferrit < 1%
    316L

  • Wetted part finishing (Ra)

    < 0,76 μm (29,92 μin)
    < 0,38 μm (14,96 μin)
    < 0,38 μm (14,96 μin) electropolished

  • Tip shape

    straight
    reduced
    tappered

  • Temperature range

    -200…650 °C (-328…1.202 °F)

  • Max. process pressure (static)

    40 bar (580 psi)

  • Max. process pressure at 400 °C

    depends on process connection

Field of application
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes.

Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industriesPressure range up to 40 bar (580 psi)For increased protection requirements of the temperature sensor regarding physical and chemical effectsFor use in pipes and containers or tanksIdeally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes

Benefits
iTHERM QuickNeck – cost and time savings thanks to simple, tool-freerecalibration of the insert usedOver 50 hygienic process connectionsGlobal portfolio with metric and imperial versionsInternational certification: hygiene standards as per 3-A®, EHEDG, ASME BPE,FDA, TSE Certificate of SuitabilityOptional: 1.4435 material, delta ferrite content < 1%Fast response time owing to reduced tips with thin wallsState of the art Tee and Elbow elements, without welds and dead legs and with best in class hygienic design

iTHERM ModuLine TT131 Welded thermowell

Metric thermowell for a wide range of industrial applications

  • Measuring principle

    Fabricated Thermowell

  • Characteristic / Application

    metric style
    according to DIN 43772
    process connection threaded, flanged, compression fitting
    with neck

  • Head connection

    external thread:
    M24 x 1.5, 1/2″ NPT, G1/2
    Female thread:
    M20 x 1.5, 1/2″ NPT, G1/2
    QuickNeck

  • Maximum standard immersion length

    4.500 mm (177″)

  • Max. immersion length on request

    4.500 mm (177″)

  • Process connection

    Thread:
    G3/8″, G1/2″, G3/4″, G1″
    NPT1/2″, NPT3/4″, NPT 1″
    M18x1.5, M20x1.5, M27x2, M33x2
    R1/2″, R3/4″
    Cap-nut:
    M20x1.5, G1/2″, G3/4″
    Compression fitting:
    NPT1/2″, G1/2″, G1″
    Flansche:
    DN15 PN40 B1, C
    DN25 PN20, PN40, PN100 B1, B2, C
    DN40 PN40 B1
    DN50 PN40 B1
    ASME 1″ 150 RF
    ASME 1″ 300 RF
    ASME 1 1/2″ 150 RF
    ASME 2″ 150 RF
    ASME 2″ 300 RF

  • Thermowell root diameter

    9×1,25 mm
    11×2 mm
    12×2,5 mm
    14×2 mm
    16×3,5 mm
    1/4″ SCH80
    1/2″ SCH80
    1/2″ SCH40

  • Medium contact material

    316 (1.4401)
    316L (1.4404)
    316Ti (1.4571)
    Alloy 600 (2.4816)
    Alloy C276 (2.4819)
    Alloy 446 (1.4749)
    Alloy 321 (1.4541)
    Sheath PTFE
    Sheath Tantal

  • Wetted part finishing (Ra)

    < 1.6 μm (63.00 μin)

  • Tip shape

    straight
    reduced
    tapered
    optimized for quick response times

  • Temperature range

    -200…1.100 °C (-328…2.012 °F)

  • Max. process pressure (static)

    Depending on configuration up to 100 bar

  • Max. process pressure at 400 °C

    Depending on configuration

Field of application
This thermowell designed according to DIN 43772 guarantees a high resistance to most industrial process environments. It is made from pipe or tube and is available in a wide range of diameters and materials. A specially designed thermowell tip ensures fast response times for a more efficient process control. Oversheaths in PTFE or tantalum can withstand extremely corrosive process conditions. It is offered with a variety of process connections: flanges, threads, weld-in or compression fittings.

Protects the temperature sensor against physical and chemical stressHigh robustness for challenging process conditionsPressure range: up to 100 bar (1450 psi)For use in pipes, containers or tanksImproved ease of maintenance (sensor replacement without process shutdown) and recalibration of the measuring point

Benefits
Modular configuration according to DIN 43772iTHERM QuickNeck: cost and time savings thanks to simple, tool-free recalibration of the insert Extension, immersion length and total length can be chosen according to process requirements Wide choice of dimensions, materials and process connections available Specially designed tip for fast response times

iTHERM ModuLine TST434B RTD thermometer

Modular resistance thermometer for outdoor or indoor ambient temperature measurement

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    probe for ambient temperature measurement
    without neck

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Outer diameter protection tube / Insert

    20,0 mm (0,79”)

  • Material protection tube/ thermowell

    Aluminium

  • Operating temperature range

    PT 100:
    -50 °C …150 °C
    (-58 °F …302 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class A acc. to IEC 60751
    class B acc. to IEC 60751

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Field of application
The iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring the room temperature in almost all industries.It is available as a complete unit including Endress+Hauser temperature transmitters for enhanced measurement accuracy and reliability compared to directly wired sensors. With a variety of common and advanced outputs and communication protocols, they offer easy customizing.

Outdoor or indoor ambient temperature measurement Maximum measuring range: –50 to +150 °C (–58 to +302 °F) Degree of protection: IP66/68 (NEMA Type 4x encl.)

Benefits
Robust terminal heads according to DIN EN 50446 or stable plastic housings offer optimal protection from extreme ambient conditionsReliable, long term stable and accurate indoor or outdoor ambient temperature measurementSimple and fast wall mountingOptional head transmitters: Analog 4 to 20 mA, HART®, PROFIBUS® PA, FOUNDATION Fieldbus™, IO-Link, PROFINET® over Ethernet-APL/SPE

TST310 RTD thermometer, temperature cable probe

Cost efficient Pt100 sensor for use in many process and laboratory applications

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    cable probe
    suitable for hazardous areas
    process connection as compression fitting

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    3,0 mm (0,12”)
    6,0 mm (0,24”)

  • Max. immersion length on request

    up to 10.000,00 mm (393,70”)

  • Material protection tube/ thermowell

    1.4404 (316L)
    1.4571 (316Ti)

  • Process connection

    male thread:
    G1/4″
    G1/2″
    M10x1
    M8x1
    compression fitting:
    G1/8″
    G1/4″
    G1/2″
    NPT1/4″
    NPT1/2″
    M10x1
    M8x1

  • Tip shape

    straight

  • Operating temperature range

    PT 100:
    -50 °C …400 °C
    (-58 °F …752 °F)

  • Max. process pressure (static)

    at 20°C: up to 75 bar (depending on the process connection)

  • Accuracy

    class A acc. to IEC 60751
    class B acc. to IEC 60751
    class AA acc. to IEC 60751

  • Response time

    t50 = 3 s
    t90 = 6 s

  • Integration head transmitter

    no

  • Ex – approvals

    ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
    ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
    ATEX II1G Ex ia IIC T6
    ATEX II 3 G Ex nA IIC T6, II3D
    NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
    EAC Ex ia
    UK II1G Ex ia IIC T6 Ga
    UK II1/2D Ex ia IIIC Da/Db, II1G Ex ia IIC T6 Ga
    UK II1D Ex ia IIIC Da, II1G Ex ia IIC T6 Ga
    UK II 3 G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc
    IECEx Ex ia IIC T6 Ga
    NEPSI Ex nA IIC T6

Field of application
The RTD cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid medium like air, water, oil, etc. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.

The resistance thermometer is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid media like air, water, oil and others.

Benefits
High flexibility through user-specific insertion lengths and variable process connectionsFast response timeSingle or double Pt100 sensor of accuracy class A, B, or AA as per IEC 60751Types of protection for use in hazardous locations: Intrinsic safety (Ex ia) and non-sparking (Ex nA) Marine approval

iTEMP TMT86 head transmitter with Ethernet-APL

Ethernet-APL head temperature transmitter for the use in hazardous areas

  • Measuring principle

    Head transmitter

  • Input

    2 x RTD, TC, Ohm, mV

  • Output

    PROFINET

  • Auxiliary power supply

    9,6…15 V DC (Ethernet-APL)
    20…30 V DC (SPE)

  • Communication

    PROFINET with Ethernet-APL

  • Installation

    Terminal head form B / in field

  • Accuracy

    (Pt100, -50…200 °C) <= 0,1 K
    (Pt100, -58…392 °F) <= 0,18 °F

  • Galvanic isolation

    yes

  • Certification

    ATEX II1G Ex ia IIC T6
    ATEX II3G Ex ic IIC T6 Gc
    ATEX II3D Ex tc IIIC Dc
    ATEX II2G Ex ia IIC T6, II3D Ex ia IIIC Dc
    ATEX II3G Ex ec IIC T6, II3D
    ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
    CSA C/US General Purpose
    CSA C/US IS I/1/A-D, AEx/Ex ia IIC, NI I/2/A-D, AEx/Ex ec IIC Gc
    CSA XP, NI, DIP I, II, III/1+2/A-G
    EAC Ex ia IIC T6 Ga
    EAC Ex d IIC T6 Gb
    IECEx Ex d T6 Gb, Ex tb IIIC Db
    KC Ex ia IIC T6 Ga
    KC Ex db IIC T6 Gb
    INMETRO Ex ia IIC T6 Ga
    INMETRO Ex d T6 Gb, Ex tb IIIC Db
    NEPSI Ex ia IIC T4/T5/T6
    NEPSI Ex d IIC T6 Gb
    UK Ex ia IIC T6 Ga
    UK Ex d IIC T6 Gb
    ATEX IECEx II1G Ex ia IIC T6 Ga
    ATEX IECEx II2D Ex tb IIIC Db

Field of application
The iTEMP TMT86 is a reliable, intelligent and future proof dual-channel Ethernet-APL PROFINET temperature head transmitter for thermometers with terminal head form B and is suitable for use in hazardous areas. ​Beneficial diagnostic functions like corrosion monitoring of the sensor wires help to improve the plant up-time. The embedded webserver and the up-to-date FDI package simplifies the device configuration and integration.

Ethernet-APL: 2-wire Ethernet IEEE 802.3cg 10BASE-T1LTemperature measurement with two independent universal inputs (RTD, Ω, TC, mV)System integration with PROFINET®Installation in terminal head form B (flat face) as per DIN EN 50446Optional: installation in field housing for Ex d applicationsReliability, long-term stability, high precision and advanced diagnostic function in critical processes

Benefits
Digital communication down to the field level, even in explosive atmospheresEasy and standardized system integration via PROFINET® Profile 4Integrated web server offers simplicity during commissioning and maintenanceHigh accuracy of measuring point through sensor-transmitter matchingReliable operation with sensor monitoring and device hardware fault recognitionFast and tool-free wiring thanks to push-in terminal technology, optionalAttachable measured value display, optional

iTEMP TMT71 Temperature transmitter

Transformation of sensor signals into stable and standardized output signals for all industries

  • Measuring principle

    Head transmitter

  • Input

    1 x RTD, TC, Ohm, mV

  • Output

    1 x analog 4…20 mA

  • Auxiliary power supply

    10…36 V DC (Head transmitter)
    11…36 V DC (DIN rail device)
    10/11…30 V DC (Ex ia)

  • Communication

    pc-programmable
    Bluetooth® wireless technology

  • Installation

    Terminal head form B / DIN rail / field mount housing

  • Accuracy

    (Pt100, -50…200 °C) <= 0,1 K
    (Pt100, -58…392 °F) <= 0,18 °F

  • Galvanic isolation

    yes

  • Certification

    ATEX II1G Ex ia IIC T6
    ATEX II3G Ex ic IIC T6 Gc
    ATEX II3D Ex tc IIIC Dc
    ATEX II3G Ex nA IIC T6 Gc
    ATEX II2G Ex ia IIC T6 Gb, II3D
    ATEX II3G Ex nA IIC T6 Gc, II3D
    ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
    CSA C/US General Purpose
    CSA C/US IS, Ex ec I/1+2/A-D
    CSA C/US XP, DIP I, II, III/1+2/A-G
    EAC Ex ia IIC T6 Ga
    EAC Ex d IIC T6 Gb
    IECEx Ex nA IIC T6 Gc
    IECEx Ex d T6 Gb, Ex tb IIIC Db
    INMETRO Ex ia IIC T6 Ga
    INMETRO Ex d T6 Gb, Ex tb IIIC Db
    INMETRO Ex nA IIC T6 Gc
    NEPSI Ex ia IIC T6 Ga
    NEPSI Ex d IIC T6 Gb
    NEPSI Ex nA II T6 Gc
    UK II1G Ex ia IIC T6 Ga
    UK II3D Ex tc IIIC Dc
    UK II2G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
    UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
    UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
    ATEX IECEx II1G Ex ia IIC T6 Ga
    ATEX IECEx II2D Ex tb IIIC Db

Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals. The standardized 4 to 20 mA output signal is used for process measurement. Swift and easy commissioning, operation and maintenance via PC software or with integrated Bluetooth® technology and Endress+Hauser SmartBlue App.

Bluetooth®-enabled or PC programmable temperature transmitter for the conversion of various input signals into a scalable, analog 4 to 20 mA output signalImproved process efficiency and increased plant uptimeUniversal input for resistance thermometers (RTD), thermocouples (TC), resistance transmitters (Ω) and voltage transmitters (mV)Installation in terminal head form B as per DIN EN 50446Installation in cabinets with DIN rail housingOptional installation in field housing for Ex d applications

Benefits
Safe operation in hazardous areas thanks to international approvals Reliable operation thanks to sensor and device monitoring Integrated Bluetooth® interface for the wireless display of measured values and configuration via Endress+Hauser SmartBlue App, optionalUser-friendly guided user interface concept also on-site via Bluetooth® Available with plug-on display TID10 Diagnostics information according to NAMUR NE 107

iTEMP TMT36 IO-Link temperature head transmitter

Accurate and reliable process temperature measurement for one RTD sensor with integrated IO-Link function

  • Measuring principle

    Head transmitter

  • Input

    1 x RTD

  • Output

    1 x IO-Link

  • Auxiliary power supply

    18…30 V DC

  • Communication

    IO-Link

  • Installation

    Terminal head form B

  • Accuracy

    (Pt100, -50…200 °C) <= 0,15 K
    (Pt100, -58…392 °F) <= 0,15 K

  • Galvanic isolation

    no

  • Certification

    CSA General Purpose

Field of application
The iTEMP TMT36 is a reliable, long lasting, single-channel IO-Link temperature head transmitter with a form B connection head. Individual transmitter-sensor matching with Callendar van Dusen linearization further improves the temperature measurement accuracy of RTD sensors. The IO-Link capable iTEMP TMT36 can be installed in all modular Endress+Hauser thermometers to digitize a larger number of applications with special requirements using IO-Link technology.

The temperature transmitter is characterized by its reliability, long-term stability, high precision and diagnostic functionsFor maximum safety and availabilityInstallation in terminal head form B (flat face), or on DIN rail with DIN rail clipIO-Link (1x PNP, NPN or push-pull switch output, configurable)

Benefits
Push-in terminals for fast, tool-free wiring during installation or maintenanceSimple parametrization via free software tools (requires SFP20)​Transmitter-sensor matching using Callendar van Dusen linearization for critical measurement points​Improved RTD measurement accuracy up to 0.15 K and long-term stabilitySafe and reliable operationIO-Link technology to digitize the the last mile of your plant

iTEMP TMT31 head mount temperature transmitter

Accurate and reliable process temperature measurements for RTD sensors

  • Measuring principle

    Head transmitter

  • Input

    1x Pt100 / Pt1000

  • Output

    1 x analog 4…20 mA

  • Auxiliary power supply

    10…36 V DC

  • Communication

    pc-programmable

  • Installation

    Terminal head form B

  • Accuracy

    (Pt100,Pt1000, -50…+250°C) <= 0,1 K
    (Pt100,Pt1000, -58…+482°F) <= 0,18° F

  • Galvanic isolation

    no

  • Certification

    ATEX II3G Ex ec IIC Gc
    CSA C/US General Purpose
    CSA C/US NI Cl.I Div.2 Gr.A-D,Ex ec IIC Gc
    ATEX II3G Ex ec IIC Gc + CSA C/US Ex ec IIC Gc
    DNV (GL) marine approval

Field of application
The iTEMP TMT31 is a reliable, long-term stable, single-channel 4 to 20 mA temperature transmitter for thermometers with terminal head Form B suited for use in Zone 2 / Div. 2 areas. Individual transmitter-sensor matching with Callendar-Van Dusen linearization further improves your temperature measurement accuracy for RTD sensors. Push-in terminals for quick wiring facilitate installation. The device is available pre-configured or can easily be parametrized using free software tools.

Highly accurate and reliable temperature measurement for various industrial and hygienic process applicationsCertified for use in Zone 2 (Ex ec) / Div. 2 areasInput: Single RTD sensor input for Pt100 or Pt1000 (2-/3- or 4-wire) sensorsOutput: 4 to 20 mA analog outputConfigurable or factory-set fixed parameters Installation in terminal heads Form B as per DIN EN 50446

Benefits
Push-in terminals for fast, tool-free wiring during installation or maintenanceSimple parametrization via free software tools (requires FXA291 or TXU10)​Transmitter-sensor matching using Callendar-Van Dusen linearization for critical measurement points​Improved RTD measurement accuracy up to 0.1 K and long-term stabilityDiagnostics information according to NAMUR NE 107Ready-to-use: Factory pre-configured

iTEMP TMT142B HART® 7 temperature transmitter

Smart, rugged, innovative: New generation temperature field transmitter with Bluetooth®

iTHERM MultiSens Bundle TMS31 Multipoint RTD/TC thermometer

Flexible metal rope multipoint for silos and storage tank applications

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    imperial style
    easy-to-use
    suitable for hazardous areas
    process connection: flanged
    Storage applications
    linear sensor distribution
    modular design

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    25 mm
    37 mm

  • Max. immersion length on request

    up to 60.000,00 mm (2.360”)

  • Material protection tube/ thermowell

    1.4401 (316)
    1.4435 (316L)

  • Process connection

    flange:
    1 1/2″ ASME/ANSI B16.5 150
    …300
    2″ ASME/ANSI B16.5 150
    …300
    3″ ASME/ANSI B16.5 150
    ..300
    4″ASME/ANSI B16.5 150
    ..300
    DN40 EN/DIN 1092.1 PN16
    …PN40
    DN50 EN/DIN 1092.1 PN16
    …PN40
    DN80 EN/DIN 1092.1 PN16
    …PN40
    DN100 EN/DIN 1092.1 PN16
    …PN40

  • Tip shape

    straight

  • Operating temperature range

    Type K:
    max. 800 °C
    (max. 1.472 °F)
    Type J:
    max. 520 °C
    (max. 968 °F)
    Pt100 WW:
    -200…600 °C
    (-328…1.112 °F)
    Pt100 StrongSens:
    -50…500 °C
    (-58…932 °F)
    Pt100 TF:
    -50…400 °C
    (-58…752 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Accuracy

    class 1 acc. to IEC 60584
    class 2 acc. to IEC 60584
    class Special ASTM E230 and ANSI MC 96.1
    IEC60751 Class A
    IEC60751 Class AA

  • Response time

    TC
    t50 = 1 s
    t90 = 2 s
    RTD
    t50 = 3 s
    t90 = 6 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex – approvals

    ATEX
    IECEX
    UL
    FM
    CSA

  • Certification

    SIL (transmitter only)

Field of application
The iTHERM TMS31 is a versatile, modular multipoint temperature assembly designed for temperature average detection and profiling in grain, organic bulk material storage silos and in oil, fuel storage tanks.The device’s mechanical robustness and accurate temperature sensors offer the necessary characteristics for safe, reliable and economic product storage operations. In its standard configuration it is available with up to 20 thermocouple (TC) or RTD sensors fitted to a primary metal rope.

Oil storage tanksBulk material silos

Benefits
Easy installation and process integration thanks to a high degree of customization Flexible rope that adapts to different silos or tank operating conditions (filling, emptying, storage, …) Intrinsically safe device for use in Ex areas Highly robust design for a long product lifetime and continuous monitoring in all conditions

iTHERM TrustSens TM372 Self-calibrating temperature sensor

100% compliance, 0% effort Hygienic compact RTD thermometer, US style

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    self-calibrating
    imperial style
    compact temperature probe
    hygienic design
    hygienic process connection

  • Thermowell / protection tube

    without
    incl. thermowell
    incl. Tee-/elbow thermowell

  • Insert / probe

    pipe version, isolated wires, not flexible

  • Outer diameter protection tube / Insert

    1/4” (6,35 mm)
    3/8” (9,53 mm)
    1/2″ (12,7 mm)

  • Max. immersion length on request

    up to 28” (711 mm)
    others on request

  • Material protection tube/ thermowell

    316L

  • Process connection

    Weld-in adapter
    Tri-clamp
    Clamp-connections according to ISO2852
    G3/4″ Liquiphant
    G1″ Liquiphant
    Varivent
    T- and elbow thermowell

  • Tip shape

    straight
    reduced

  • Surface roughness Ra

    30 μin (0,76 μm)
    15 μin (0,38 μm )
    15 μin (0,38 μm ) electropolished

  • Operating temperature range

    PT 100:
    -40 °C …160 °C (-40 °F …320 °F),
    optional up to 190 °C (374 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Response time

    t50 = 2,5 s
    t90 =9,5s

  • Integration head transmitter

    no (4…20mA Signal)

  • Ex – approvals

    CSA C/US IS, I/1+2/A-F

Field of application
The award-winning smart temperature probe with integrated HART® transmitter and Heartbeat Technology features the world’s first RTD sensor unit capable of fully automated in-situ self-calibration. It effectively eliminates the risk of undetected non-conformities, reduces production downtime and increases product safety and process efficiency in applications of the food & beverage and life sciences industries. The device is fully compliant to FDA 21 CFR Part 11 regulations and GMP rules.

Specially designed for use in hygienic and aseptic applications in the food & beverage and life sciences industriesMeasuring range: –40 to 190 °C (–40 to 374 °F)Pressure range up to 50 bar (725 psi)Protection class: IP65/67 or IP69 Communication: Analog output 4 to 20 mA, HART® protocol

Benefits
Risk and cost reduction thanks to self-calibration and Heartbeat TechnologyNo production downtime due to an automated and fully traceable inline self-calibrationAutomatized documentation, memory for 350 calibration points.
Printable calibration certificate – audit proof.Automated 4 to 20 mA loop check for saving time and increasing safety in your process. See how iTHERM TrustSens can perform a fully automated loop check in five easy steps. The video shows the device set up and benefits for your process.Elimination of non-conformities or undetected failures International certifications and approvals:– EHEDG, ASME BPE, FDA, 3-A, 1935/2004, 2023/2006, 10/2011, CE CRN, CSA General Purpose, Explosion protection, e.g. ATEX/IECExHighest accuracy of measuring point through sensor-transmitter matching

iTHERM ModuLine TM121

Thermometer with RTD or TC insert complete with manufactured thermowell produced from pipe material

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    modular temperature assembly
    universal range of application
    with neck
    incl. thermowell / protection tube (metal)

  • Thermowell / protection tube

    welded protection tube or to be used with thermowell

  • Insert / probe

    Basis Sensortechnologie

  • Outer diameter protection tube / Insert

    Thermowell:
    9×1,25 mm
    11×2 mm

  • Max. immersion length on request

    up to 1.000,0 mm (39”)

  • Material protection tube/ thermowell

    316L (1.4404)

  • Process connection

    Thread:
    G1/2″
    NPT1/2″
    M20x1.5, M27x2, M33x2
    Compression fitting:
    NPT1/2″, G1/2″, G1″
    Flansche:
    DN25 DN40 B1
    ASME 1″ 150 RF
    ASME 1″ 300 RF
    ASME 1 1/2″ 150 RF
    ASME 2″ 150 RF
    ASME 2″ 300 RF

  • Tip shape

    straight

  • Operating temperature range

    Basic PT100 TF:
    -50 °C …200 °C
    (-58 °F …392 °F)
    Typ K:
    max. 1.100 °C
    (max. 2.012 °F)

  • Max. process pressure (static)

    depending on the configuration

  • Accuracy

    Class A acc. to IEC 60751
    Class B acc. to IEC 60751
    Class standard acc. to ASTM E230
    Class 2 acc. to IEC 60584-2

  • Response time

    t90 around 100 s
    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART)

Field of application
RTD or TC assembly characterized by basic sensor technology, application in non-hazardous areas, standard extension neck, low-cost unit. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.

Universal range of applicationApplication in non-hazardous areasMeasuring range: –50 to +650 °C (–58 to +1202 °F)Pressure range up to 50 bar (725 psi)Degree of protection: up to IP 68

Benefits
Economical, reliable measurementUser-friendly from product selection to maintenance Wide range of process connectionsEasy and safe device setup and service using Bluetooth® communication

iTHERM ModuLine TM101

RTD or thermocouple temperature probe for direct installation without thermowell in various industrial applications

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    Basic technologie
    metric style
    universal range of application
    direct process contact

  • Thermowell / protection tube

    without, direct process contact

  • Insert / probe

    Basis Sensortechnologie

  • Outer diameter protection tube / Insert

    Insert:
    6,0 mm

  • Max. immersion length on request

    up to 1.000,0 mm (39”)

  • Material protection tube/ thermowell

    Insert Material:
    316L (1.4404)
    Alloy 600 (2.4816)

  • Process connection

    Thread:
    G1/2″, G1/4″
    NPT1/2″
    M18x1.5, M20x1.5
    Cap-nut:
    G1/2″, G3/4″
    Compression fitting, also spring load:
    NPT1/2″, G1/2″

  • Tip shape

    straight

  • Operating temperature range

    Basic PT100 TF:
    -50 °C …200 °C
    (-58 °F …392 °F)
    Typ K:
    max. 1.100 °C
    (max. 2.012 °F)

  • Max. process pressure (static)

    depending on the configuration

  • Accuracy

    Class A acc. to IEC 60751
    Class B acc. to IEC 60751
    Class standard acc. to ASTM E230
    Class 2 acc. to IEC 60584-2

  • Response time

    t90 around 17 s
    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART)

Field of application
Basic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert for use in non-hazardous areas. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.

Wide range of applicationsMeasuring range: -50 to +650 °C (-58 to +1202 °F)Pressure range: up to 50 bar (725 psi)Protection class: up to IP68For use in non-hazardous areas

Benefits
Excellent value for money and fast global deliveryUser-friendly product selection, smart design for easy maintenanceWide range of process connectionsBluetooth® connectivity (optional)

TH14 Modular RTD thermometer, US style

Best in class temperature measurement technology for general applications

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    US style
    modular temperature assembly
    flanged process connection
    with extension
    incl. thermowell

  • Thermowell / protection tube

    bar stock (drilled)

  • Insert / probe

    mineral insulated (MI), flexible
    PTFE-insulated, rigid

  • Outer diameter protection tube / Insert

    3/4” (19,05 mm)
    17/16” (26,99 mm)
    22,23 mm … 26,99 mm
    (0,88” … 1,06”)

  • Max. immersion length on request

    up to 24″ (609 mm)
    others on request

  • Material protection tube/ thermowell

    316/316L
    others on request

  • Optional coating

    available on request

  • Process connection

    flange:
    ASME 1″ 150 RF (B16.5)
    ASME 1″ 300 RF (B16.5)
    ASME 1″ 600 RF (B16.5)
    ASME 1″ 900/1500 RF (B16.5)
    ASME 1.5″ 150 RF (B16.5)
    ASME 1.5″ 300 RF (B16.5)
    ASME 1.5″ 600 RF (B16.5)
    ASME 1.5″ 900/1500 RF (B16.5)
    ASME 2″ 150 RF (B16.5)
    ASME 2″ 300 RF (B16.5)
    ASME 2″ 600 RF (B16.5)
    ASME 2″ 900/1500 RF (B16.5)
    ASME 3″ 150 RF (B16.5)
    ASME 3″ 300 RF (B16.5)
    ASME 3″ 600 RF (B16.5)
    ASME 3″ 900/1500 RF (B16.5)

  • Tip shape

    straight
    tapered

  • Surface roughness Ra

    32 μin (0.80 μm)

  • Operating temperature range

    PT100 WW:
    -200 °C … 600 °C
    (-328 °F … 1.112 °F)
    StrongSens:
    -50 °C … 500 °C
    (-58 °F … 932 °F)
    PT100 TF:
    -50 °C … 200 °C
    (-58 °F … 392 °F)

  • Max. process pressure (static)

    at 20 °C: 500 bar (7.252 psi)
    depends on configuration

  • Accuracy

    class AA acc. to IEC 60751
    class A acc. to IEC 60751
    class B acc. to IEC 60751

  • Response time

    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex – approvals

    transmitter only
    FM IS
    CSA IS
    FM/CSA IS

  • Certification

    SIL (transmitter only)

Field of application
The high modular thermometer is used for several applications with harsh environments, e.g. in power plants, refineries or in the chemical or petrochemical industry. The robust device with barstock thermowell and flange connection in SS316 or INCONEL600 and different head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability.

The TH14 temperature sensors are RTD assemblies installed in thermowells and designed for use in all types of process industries, including harsh environments, due to their rugged design. They are made up of a measurement probe with an insulated RTD element, sheath and a thermowell made of barstock material.The sensor assemblies can be used in process industries such as:ChemicalsPetrochemical Power plantsRefineriesOffshore platforms

Benefits
High flexibility due to modular assembly with standard terminal heads and customized immersion lengthOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications. Remove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solutionAll iTEMP® transmitters provide long term stability ≤ 0.05 % per yearFast response time with reduced/tapered tip formHead transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™

TAF12T High temperature TC thermometer

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style
    modular temperature assembly
    high temperature (furnace)
    ncl. triple ceramic thermowell

  • Thermowell / protection tube

    ceramic protection tube and 2x inner tube

  • Insert / probe

    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    24,0 mm (0,94″)
    26,0 mm (1,02″)

  • Max. immersion length on request

    up to 3.500,00 mm (137,80”)

  • Material protection tube/ thermowell

    Ceramic (C530/C610/C799)

  • Process connection

    compression fitting:
    G11/2″

  • Tip shape

    straight

  • Operating temperature range

    Type S:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type R:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type B:
    600 °C …1.700 °C
    (1.112 °F …3.092 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Field of application
Measuring points with extremely high process temperatures require these thermometers with ceramic thermowells and special metal thermocouples, such as platinum and rhodium. The thermowell as well as the intermediate and internal sheath of ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

The TAF12T are assemblies with triple ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.Process temperatures: up to +1700 °C (+3092 °F)

Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistanceLong term stable measurement due to sensor protection with non-porous materialsFlexible product selection by modular designOptimized life cycle costs by means of replaceable spare parts

TAF12D High temperature TC thermometer

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style
    modular temperature assembly
    high temperature probe (furnace)
    incl. double ceramic thermowell

  • Thermowell / protection tube

    ceramic protection tube and inner tube

  • Insert / probe

    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    14,0 mm (0,55″)
    15,0 mm (0,59″)

  • Max. immersion length on request

    up to 3.500,00 mm (137,80”)

  • Material protection tube/ thermowell

    Ceramic (C610/C799)

  • Process connection

    compression fitting:
    G3/4″
    G1″
    G11/2″
    adjustable Flange

  • Tip shape

    straight

  • Operating temperature range

    Type S:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type R:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type B:
    600 °C …1.700 °C
    (1.112 °F …3.092 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Field of application
Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

The TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.Process temperatures: up to +1700 °C (+3092 °F)

Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance Long term stable measurement due to sensor protection with non-porous materialsFlexible product selection by modular designOptimized life cycle costs by means of replaceable spare parts

TAF11 High temperature TC thermometer

Applicable for steel treatment (annealing), concrete furnaces and primaries

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style
    modular temperature assembly
    high temperature probe (furnace)
    incl. single ceramic thermowell

  • Thermowell / protection tube

    ceramic protection tube

  • Insert / probe

    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    14,0 mm (0,55″)
    16,0 mm (0,59″)
    17,0 mm (0,68″)
    22,0 mm (0,87″)
    24,0 mm (0,94″)
    26,6 mm (1,05″)

  • Max. immersion length on request

    up to 4.000,00 mm (157,48”)

  • Material protection tube/ thermowell

    Ceramic (C610)
    silicon nitride ceramic (SiN)
    sintered silicon carbide (SiC)

  • Process connection

    compression fitting:
    G3/4″
    G1″
    G11/2″
    adjustable Flange

  • Tip shape

    straight

  • Operating temperature range

    Type K:
    -40 °C …1.300 °C
    (-40 °F …2.372 °F)
    Type J:
    -40 °C …750 °C
    (-40 °F …1.382 °F)
    Type N:
    -40 °C …1.150 °C
    (-40 °F …2102 °F)
    Type S:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type R:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type B:
    600 °C …1.600 °C
    (1.112 °F …2.912 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Field of application
Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell made from special materials serves as protection from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

Applicable for steel treatment (annealing), concrete furnaces and primaries. It contains a single or double TC insert and a ceramic protection tube.Process temperatures: up to +1600 °C (+2912 °F)

Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistanceLong term stable measurement due to sensor protection with non-porous materialsFlexible product selection by modular designOptimized life cycle costs by means of replaceable spare parts

T14 Explosion proof Pt100 thermometer, US style

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    Explosion Proof US style
    modular temperature assembly
    for heavy duty applications
    flanged process connection
    with extension
    incl. thermowell

  • Thermowell / protection tube

    bar stock (drilled)

  • Insert / probe

    mineral insulated (MI), flexible
    PTFE-insulated, rigid

  • Outer diameter protection tube / Insert

    7/8” (22,23 mm)
    17/16” (26,99 mm)

  • Max. immersion length on request

    up to 22.5″ (571 mm)
    others on request

  • Material protection tube/ thermowell

    316/316L
    others on request

  • Optional coating

    Available on request

  • Process connection

    flange:
    ASME 1″ 150 RF (B16.5)
    ASME 1″ 300 RF (B16.5)
    ASME 1″ 600 RF (B16.5)
    ASME 1″ 900/1500 RF (B16.5)
    ASME 1,5″ 150 RF (B16.5)
    ASME 1,5″ 300 RF (B16.5)
    ASME 1,5″ 600 RF (B16.5)
    ASME 1,5″ 900/1500 RF (B16.5)
    ASME 2″ 150 RF (B16.5)
    ASME 2″ 300 RF (B16.5)
    ASME 2″ 600 RF (B16.5)
    ASME 2″ 900/1500 RF (B16.5)

  • Tip shape

    straight
    tapered

  • Surface roughness Ra

    32 μin. (0.80 μm)

  • Operating temperature range

    PT100 WW:
    -200 °C … 600 °C
    (-328 °F … 1.112 °F)
    PT100 TF:
    -50 °C … 200 °C
    (-58 °F … 392 °F)

  • Max. process pressure (static)

    at 20 °C: 500 bar (7.252 psi)
    depends on configuration

  • Accuracy

    class A acc. to IEC 60751
    class B acc. to IEC 60751

  • Response time

    depending on configuration
    63% rt = 20 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex – approvals

    FM XP DIP Class I,II,III Div. 1+2
    FM XP NI DIP Class I,II,III Div. 1+2
    CSA XP DIP Class I,II,III Div. 1+2
    CSA XP NI DIP Class I,II,III Div. 1+2
    FM/CSA XP DIP Class I,II,III Div. 1+2
    FM/CSA XP NI DIP Class I,II,III Div.1+2
    CSA C/US XP, DIP I, II, III/1/A-G
    cCSAus General Purpose

  • Certification

    SIL (transmitter only)

Field of application
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. A optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.

The T14 temperature sensor is a RTD assembly installed in Thermowell and designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.The sensor is made up of a measurement probe with an insulated RTD element, sheath and a thermowell made of bar-stock material.
The sensor assembly can be used in process industries such as:
Chemicals
Petrochemical
Refineries
Offshore Platforms

Benefits
FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safetyOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applicationsRemove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solutionAll iTEMP transmitters provide long term stability ≤0.05% per year

Translate »