Vibronic Point level detection Nivotester FTL325P

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Switching unit PFM technology for rail mounting
    Intrinsically safe
    Highest SIL safety

  • Specialities

    If sensors are redundant, SIL3

  • Supply / Communication

    85…253 V AC,
    20…30 V AC/ 20…60 V DC

  • Ambient temperature

    Single installation:
    -20 °C … 60 °C
    (-4 °F … 140 °F)
    Rail mounting:
    -20 °C … 50 °C
    (-4 °F … 122 °F)

  • Communication

    1 Channel: 1 Level SPDT + 1 Alarm SPST
    3 Channel: 3 level SPDT + 1 Alarm SPST

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG
    SIL

  • Measuring principle

    Vibration Solids

  • Characteristic / Application

    Switching unit PFM technology for rail mounting
    Intrinsically safe

  • Supply / Communication

    85…253 V AC,
    20…30 V AC / 20…60 V DC

  • Ambient temperature

    Single installation:
    -20 °C … 60 °C
    (-4°F … 140 °F)
    Rail mounting:
    -20 °C … 50 °C
    (-4 °F … 122 °F)

  • Communication

    1 Channel: 1 Level SPDT + 1 Alarm SPST
    3 Channel: 3 level SPDT + 1 Alarm SPST

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    Overfill prevention WHG
    SIL

Field of application
The switching unit FTL325P is used for point level detection in liquid tanks and bulk material silos, also in hazardous explosion areas. Also suitable for liquid detection in pipes for dry running protection for pumps and overfill prevention for tanks with combustible or non-combustible liquids harmful to water. Up to 3 measuring devices for two-point control and point level detection. Functional safety up to SIL3 in accordance to IEC 61508 using Liquiphant with electronic insert FEL57.

Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant.

Ambient temperature: -20 to +70°C (-4 to +158°F)
International explosion protection certificates, overfill prevention WHG, marine approvals

Benefits
Nivotester FTL325P for connecting one, two or three measuring cells (1-, 2- or 3-channel devices)Intrinsically safe signal circuits Ex ia for use of measuring sensor in explosion hazardous areasFunctional safety up to SIL2 through line monitoring. Simplified proof testing to WHG/SIL by pressing push-buttonDIN Rail housing for simple series installation on standard rails in switch cabinetSimple wiring using pluggable terminal blocksInputs are galvanically isolated from each other, from the mains and from the outputs