The UFC 300 is an ultrasonic signal converter. Combined with the flow sensor OPTISONIC 6000 it forms the OPTISONIC 6300 ultrasonic
The UFC 400 is a 4-wire ultrasonic signal converter. Combined with the flow sensors OPTISONIC 3000 and OPTISONIC 3000 District Heating
The VFC 100 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 2000 flow sensor to form
The VFC 200 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 4000 flow sensor to form the
Wireless-MUX is a gateway for data communication via Bluetooth. The multiplexer (MUX) set offers wireless remote transmission of flow, conductivity,
Radioline is a licence-free transmission system (Radioline) for remote transfer of data in infrastructure applications. The solution offers wireless signal
OPTIBRIDGE 3880 is a fully autonomous wireless communication system for remote access to measurement data from all sorts of measurements in
The EtherNet/IP™ Interface Box equips OPTIMASS 1010, OPTIMASS 3010 and OPTIMASS 7010 instruments with a state-of-the-art EtherNet/IP™ interface. Designed for
The SUMMIT 8800 is a digital flow computer for custody transfer (CT) measurement. Its state of the art full colour graphical
The OPTIBAR FC 1000 is a compact, high performance flow computer for volumetric flow calculation and heat quantity measurement of
The DW 184 is an insertion-type flow controller for checking the flow velocity of liquids without auxiliary power. It is suitable
The DW 183 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It
The DW 182 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It
The DW 181 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It
The DWM 2000 is a 3-wire electromagnetic flowmeter to monitor the flow of conductive liquids, pastes and slurries. The range of
The DWM 1000 is a 2-wire electromagnetic flow controller to monitor the flow of conductive liquids, pastes and slurries. The switching
The OPTIPROBE is an electromagnetic insertion-type flowmeter for flow monitoring of conductive clean liquids in water and wastewater applications. The
The OPTISWIRL 2100 is a Vortex flowmeter for basic utility applications in all industries. The 2-wire device is the ideal
The cone flowmeter is a differential pressure (DP) flowmeter specifically engineered for applications with high accuracy requirements and disturbed flow
The wedge flowmeter is designed for difficult applications where other flow technologies fail or have a very limited-service life. It
The Venturi flowmeter is based on a classical Venturi tube, an engineered primary flow element for a most efficient and
The flow nozzle meter is designed for accurate long-term stable flow measurement of liquids gases and steam, especially in high
The averaging pitot tube flowmeter requires the least installation effort of all DP flowmeters. It is cost-effective and suitable for
The integral orifice meter run assembly is a differential pressure flowmeter especially designed for smaller line sizes where the surface
The compact orifice plate with OPTIBAR DP transmitter is an economic DP flowmeter for a broad range of applications – from demi-water
The OPTISWIRL 5080 is a Vortex flowmeter for high temperature applications up to +427°C / +800°F. The flowmeter is particularly
The OPTISWIRL 4200 is a Vortex flowmeter with integrated temperature sensor. It is best suited for flow measurement of liquids,
The VA45 is a glass tube variable area (VA) flow meter for flow measurement of gases at low operating pressures
The VA40 is a glass tube variable area (VA) flowmeter for flow measurement of liquids and gases. The all-purpose flowmeter
The DK46/47/48/800 is a variable area (VA) flowmeter for monitoring and adjusting extremely small flow rates of liquids (from ≥0.04
The DK32/34 is a variable area (VA) flowmeter for measuring low flow rates of liquids and gases. The tried and
The DK37 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indicator with
The H250 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indication with

UFC 300

The UFC 300 is an ultrasonic signal converter. Combined with the flow sensor OPTISONIC 6000 it forms the OPTISONIC 6300 ultrasonic […]

The UFC 300 is an ultrasonic signal converter. Combined with the flow sensor OPTISONIC 6000 it forms the OPTISONIC 6300 ultrasonic clamp-on flowmeter for stationary flow measurement of liquids at any location.

Overview

The UFC 300 is an ultrasonic signal converter. Combined with the flow sensor OPTISONIC 6000 it forms the OPTISONIC 6300 ultrasonic clamp-on flowmeter for stationary flow measurement of liquids at any location.

UFC 400

The UFC 400 is a 4-wire ultrasonic signal converter. Combined with the flow sensors OPTISONIC 3000 and OPTISONIC 3000 District Heating

The UFC 400 is a 4-wire ultrasonic signal converter. Combined with the flow sensors OPTISONIC 3000 and OPTISONIC 3000 District Heating it forms the OPTISONIC 3400 ultrasonic flowmeter for inline flow measurement of liquids as well as the OPTISONIC 3400 District Heating ultrasonic flowmeter for use in heat metering applications. Together with the OPTISONIC 4000 HT and HP flow sensors it forms the ultrasonic flowmeters OPTISONIC 4400 HT and OPTICONIC 4400 HP  for inline flow measurement of high temperature and high pressure liquids.

Overview

The UFC 400 is a 4-wire ultrasonic signal converter. Combined with the flow sensors OPTISONIC 3000 and OPTISONIC 3000 District Heating it forms the OPTISONIC 3400 ultrasonic flowmeter for inline flow measurement of liquids as well as the OPTISONIC 3400 District Heating ultrasonic flowmeter for use in heat metering applications. Together with the OPTISONIC 4000 HT and HP flow sensors it forms the ultrasonic flowmeters OPTISONIC 4400 HT and OPTICONIC 4400 HP  for inline flow measurement of high temperature and high pressure liquids.

VFC 100

The VFC 100 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 2000 flow sensor to form

The VFC 100 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 2000 flow sensor to form the OPTISWIRL 2100 vortex flowmeter.

Overview

The VFC 100 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 2000 flow sensor to form the OPTISWIRL 2100 vortex flowmeter.

VFC 200

The VFC 200 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 4000 flow sensor to form the

The VFC 200 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 4000 flow sensor to form the OPTISWIRL 4200 vortex flowmeter.

Overview

The VFC 200 is a 2-wire Vortex signal converter. It can be combined with the OPTISWIRL 4000 flow sensor to form the OPTISWIRL 4200 vortex flowmeter.

Wireless-MUX

Wireless-MUX is a gateway for data communication via Bluetooth. The multiplexer (MUX) set offers wireless remote transmission of flow, conductivity,

Wireless-MUX is a gateway for data communication via Bluetooth. The multiplexer (MUX) set offers wireless remote transmission of flow, conductivity, pressure, temperature and analytical readings using 2 MUX modems (no IP and configuration effort). The transmission of further digital operating status values is also possible. It has a transmission distance of up to 200 m / 218.7 yd.

Overview

Wireless-MUX is a gateway for data communication via Bluetooth. The multiplexer (MUX) set offers wireless remote transmission of flow, conductivity, pressure, temperature and analytical readings using 2 MUX modems (no IP and configuration effort). The transmission of further digital operating status values is also possible. It has a transmission distance of up to 200 m / 218.7 yd.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • For fast and small networks
  • Radio link diagnostics via LED bar graph
  • Suitable for time-critical signal transmission
  • Various communication options
  • Plug and play – startup without configuration
  • Available with rugged control cabinet (IP66)
  • With omnidirectional antennas with 1.5 m / 4.9 ft cable

Radioline

Radioline is a licence-free transmission system (Radioline) for remote transfer of data in infrastructure applications. The solution offers wireless signal

Radioline is a licence-free transmission system (Radioline) for remote transfer of data in infrastructure applications. The solution offers wireless signal transmission of measuring values for flow, level, pressure, temperature, analytical and other devices via an external power-operated license-free radio modem. It transmits serial data (Modbus RTU), digital and analogue signals (0/4…20 mA) as well as digital pulses. The transmission range of the radio system is up to 20 km / 12 mi from one station to another. The range can be extended by the use of intervening stations as each station amplifies the signal to the control panel as a repeater.

The system is basically available as a pre-wired complete solution featuring wireless modules and I/O modules in rugged boxes (IP66). For connecting several measuring devices, the multifunctional solution can also be put together as a customized package with a desired number of I/O modules. Latest encryption standards provide data security.

Overview

Radioline is a licence-free transmission system (Radioline) for remote transfer of data in infrastructure applications. The solution offers wireless signal transmission of measuring values for flow, level, pressure, temperature, analytical and other devices via an external power-operated license-free radio modem. It transmits serial data (Modbus RTU), digital and analogue signals (0/4…20 mA) as well as digital pulses. The transmission range of the radio system is up to 20 km / 12 mi from one station to another. The range can be extended by the use of intervening stations as each station amplifies the signal to the control panel as a repeater.

The system is basically available as a pre-wired complete solution featuring wireless modules and I/O modules in rugged boxes (IP66). For connecting several measuring devices, the multifunctional solution can also be put together as a customized package with a desired number of I/O modules. Latest encryption standards provide data security.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • For large networks (of up to 250 stations) and distances (of up to 20 km / 12.4 mi point-to-point)
  • Enables various network structures: from a simple point-to-point connection to complex networks
  • Universal use:
    • I/O-to-I/O
    • I/O & Modbus RTU to Modbus RTU PLCs
    • I/O integration in Modbus RTU PLCs
    • Serial cable replacement RS 232/485
  • Can be extended with up to 32 I/O modules
  • Easy module replacement even during operation (hot swap)
  • License-free 868 MHz (900 MHz USA) frequency band
  • Configurable data rates of data transmission interface
  • Easy startup of wireless systems – by simply turning the thumbwheel, without any programming
  • Hazrdous area approvals

OPTIBRIDGE 3880

OPTIBRIDGE 3880 is a fully autonomous wireless communication system for remote access to measurement data from all sorts of measurements in

OPTIBRIDGE 3880 is a fully autonomous wireless communication system for remote access to measurement data from all sorts of measurements in process applications and industrial automation. The data logger comes battery powered or mains powered. It is therefore particularly suitable for water applications in remote installation areas without power supply such as water abstraction wells or drinking water transportation pipelines. This makes it the perfect match for the battery-powered WATERFLUX 3070 water meter. Due to its rugged waterproof design (IP68), the wireless system is the ideal choice for installation in flood-prone areas like manholes.

OPTIBRIDGE 3880 offers a wide range of remote data management options – from simple data logging to internet connectivity and storage for maintenance, process visualisation and data evaluation. The KROHNE tool is thus also designed for advanced applications with IIoT (Industrial Internet of Things) requirements, offering flexible and modular solutions for data acquisition and analysis in smart networks. Using integration software supplied by KROHNE, data can also be integrated into any SCADA or other software system by using industry standard protocols like e.g. OPC UA, CSV, etc.

Overview

OPTIBRIDGE 3880 is a fully autonomous wireless communication system for remote access to measurement data from all sorts of measurements in process applications and industrial automation. The data logger comes battery powered or mains powered. It is therefore particularly suitable for water applications in remote installation areas without power supply such as water abstraction wells or drinking water transportation pipelines. This makes it the perfect match for the battery-powered WATERFLUX 3070 water meter. Due to its rugged waterproof design (IP68), the wireless system is the ideal choice for installation in flood-prone areas like manholes.

OPTIBRIDGE 3880 offers a wide range of remote data management options – from simple data logging to internet connectivity and storage for maintenance, process visualisation and data evaluation. The KROHNE tool is thus also designed for advanced applications with IIoT (Industrial Internet of Things) requirements, offering flexible and modular solutions for data acquisition and analysis in smart networks. Using integration software supplied by KROHNE, data can also be integrated into any SCADA or other software system by using industry standard protocols like e.g. OPC UA, CSV, etc.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Made for IIoT (Industrial Internet of Things) applications and smart networks
  • Facilitates remote access to data from process instrumentation (e.g. flow, pressure, temperature, etc.)
  • Enables local data hosting on on-premises servers – from maintenance to process visualisation to SCADA integration via OPC-UA or CSV
  • Features the most advanced cyber-security technology, including sensor authentication and data encryption using TLS 1.3 protocol
  • Easy configuration, commissioning and device status assessment via Bluetooth and mobile smart device using the OPTIBRIDGE 3880 Setup mobile app: free download for iOS and Android
  • Rugged design: polycarbonate enclosure, IP68 rated for use in flood-prone locations
  • Allows installation in the most demanding industrial applications
  • Ultra-low power consumption: battery powered version with up to 6 years operating time; 32 Ah battery capacity

ETHERNET/MFC 010

The EtherNet/IP™ Interface Box equips OPTIMASS 1010, OPTIMASS 3010 and OPTIMASS 7010 instruments with a state-of-the-art EtherNet/IP™ interface. Designed for

The EtherNet/IP™ Interface Box equips OPTIMASS 1010, OPTIMASS 3010 and OPTIMASS 7010 instruments with a state-of-the-art EtherNet/IP™ interface. Designed for installation in a control cabinet, it offers a full-featured web-interface for configuration, maintenance and diagnostics, and for smooth and intuitive integration into major EtherNet/IP™ host systems, e.g. Rockwell and Schneider Electric.

An integrated 2-port Ethernet switch allows for flexible network topologies: multiple devices can be connected without the need for an external switch. If the application requires redundancy, the EtherNet/IP™ interface can also be deployed in ring topology. The integrated web server allows field device configuration and diagnosis using standard devices such as tablet PCs.

Overview

The EtherNet/IP Interface Box equips OPTIMASS 1010, OPTIMASS 3010 and OPTIMASS 7010 instruments with a state-of-the-art EtherNet/IP interface. Designed for installation in a control cabinet, it offers a full-featured web-interface for configuration, maintenance and diagnostics, and for smooth and intuitive integration into major EtherNet/IP host systems, e.g. Rockwell and Schneider Electric.

An integrated 2-port Ethernet switch allows for flexible network topologies: multiple devices can be connected without the need for an external switch. If the application requires redundancy, the EtherNet/IP interface can also be deployed in ring topology. The integrated web server allows field device configuration and diagnosis using standard devices such as tablet PCs.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Interface box for configuration, maintenance and diagnostics
  • Support of Device Level Ring (DLR) for redundancy
  • Password protected web server to facilitate configuration and diagnosis of the device
  • Electronic Data Sheet (EDS) available for convenient deployment
  • Add-On Instruction (AOI) available for use in Rockwell environments
  • Communicates via Modbus RTU Protocol with the attached field device

SUMMIT 8800

The SUMMIT 8800 is a digital flow computer for custody transfer (CT) measurement. Its state of the art full colour graphical

The SUMMIT 8800 is a digital flow computer for custody transfer (CT) measurement. Its state of the art full colour graphical touch screen allows a graphical representation of the measurement process, with all measured values shown in real time; Up to 5 different types of meters combined in one flow computer, with CT measurements still being processed within 0.25s.

The SUMMIT 8800 communicates via digital, analogue, serial and Ethernet interfaces to obtain the measurement and diagnostics from the field converters and analysers. All calculated values (densities, flow rates, totals, etc.) are available in Modbus format which can be read by any PLC, SCADA, accounting system etc.

Overview

The SUMMIT 8800 is a digital flow computer for custody transfer (CT) measurement. Its state of the art full colour graphical touch screen allows a graphical representation of the measurement process, with all measured values shown in real time; Up to 5 different types of meters combined in one flow computer, with CT measurements still being processed within 0.25s.

The SUMMIT 8800 communicates via digital, analogue, serial and Ethernet interfaces to obtain the measurement and diagnostics from the field converters and analysers. All calculated values (densities, flow rates, totals, etc.) are available in Modbus format which can be read by any PLC, SCADA, accounting system etc.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Approved for CT applications with up to 100% hydrogen
  • Compliant with all main international standards, such as OIML, ISO, API, AGA, GOST
  • Fully digital; no loss on accuracy due to analogue to digital conversions
  • Enhanced diagnostics with logging of preselected measured parameters
  • Modbus mapping & system compatibility (DCSs, PLCs, Supervisory, SCADA, HMI)
  • Advanced system integration incl. eReporting push, web interfacing and remote monitoring
  • Very short cycle time: down to 0.25 sec
  • Redundant operation in duty-standby configuration
  • Up to 8 non-CT multi product liquid applications per flow computer

OPTIBAR FC 1000

The OPTIBAR FC 1000 is a compact, high performance flow computer for volumetric flow calculation and heat quantity measurement of

The OPTIBAR FC 1000 is a compact, high performance flow computer for volumetric flow calculation and heat quantity measurement of liquids and gases, including saturated steam and superheated steam. Commissioning and operation of the flow computer is quick and easy thanks to its user-friendly operating philosophy. The full-screen, multi-colour touch screen offers extensive options for customising the display of process readings to suit any customer applications. Communication and measured data transmission via HART® protocol as well as the option for split-range operation allows very accurate differential pressure (DP) flow measurements especially at low working pressures. This makes the device an ideal enhancement for gas measurements with averaging pitot tubes as well as flow nozzle meters or Venturi meters with high measuring dynamics.

Its compliance with IAPWS-97 for water and steam calculations with condensate detection, makes this flow computer particularly useful for differential pressure (DP) flow measurement of saturated and super-heated steam. In addition, a variety of other calculation methods are available for the correction calculation of gases and liquids. For highly accurate measurements, the KROHNE flow computer provides correction of linearity errors of DP flow elements in real-time and in accordance with ISO 5167 requirements.

Specifications

Depending on selected device configuration

General information

Product type Flow component/auxiliary equipment
Product family name OPTIBAR
Product positioning For process control of liquids, gases and steam
Product variants
  • OPTIBAR FC 1000 for panel mounting
  • OPTIBAR FC 1000 for wall mounting

Approvals/Standards

Ingress protection IP65

Calculation methods

Flow meter Special calculation algorithms for differential pressure instruments, ultrasonic flowmeters, volumetric instruments and mass flow sensors
Heat carrier oils Parameterisation based on individual properties
Other fluids Constant characteristics
Technical gases Ideal gas law, Redlich-Kwong, Redlich-Kwong-Soave, Peng-Robinson, AGA-8 DC/GC, SGERG 88, AGA-NX19
Water and steam IAPWS-97

Input signals

Temperature 2 × Pt100
2 × 0/4 … 20 mA
Absolute pressure 1 × 0/4 … 20 mA
Flow 2 x 0/4 … 20 mA (with FSK-Modem for HART® devices)
2 × Frequency

Communication

Analogue outputs 0…20 mA, 4…20 mA
Discrete outputs 1 x mechanical relay, 2 x electronic relay
Digital outputs HART®, Modbus RTU, USB, Modbus TCP, M-Bus, Profibus-DP (with protocol converter), PROFINET (with protocol converter)

DW 184

The DW 184 is an insertion-type flow controller for checking the flow velocity of liquids without auxiliary power. It is suitable

The DW 184 is an insertion-type flow controller for checking the flow velocity of liquids without auxiliary power. It is suitable for horizontal and vertical pipes ≥DN250 / 10″. The device comes with DN150 (PN16/40) or 6” (ASME Cl 150/300) flanges. The internals are made of stainless steel (1.4404 / 316 L). The indicator is available with a linear scale with alarm positions at the top and bottom.

The DW 184 is particularly suitable for cost-effective flow detection in various applications that don’t require high accuracy. It can deal with flow velocities up to 4 m/s or 13.1 ft/s. A high-temperature version can be provided for operating conditions up to +300°C / +570°F. The mechanical flow controller is available as non-hazardous, intrinsically-safe or explosion-proof version.

Overview

The DW 184 is an insertion-type flow controller for checking the flow velocity of liquids without auxiliary power. It is suitable for horizontal and vertical pipes ≥DN250 / 10″. The device comes with DN150 (PN16/40) or 6” (ASME Cl 150/300) flanges. The internals are made of stainless steel (1.4404 / 316 L). The indicator is available with a linear scale with alarm positions at the top and bottom.

The DW 184 is particularly suitable for cost-effective flow detection in various applications that don’t require high accuracy. It can deal with flow velocities up to 4 m/s or 13.1 ft/s. A high-temperature version can be provided for operating conditions up to +300°C / +570°F. The mechanical flow controller is available as non-hazardous, intrinsically-safe or explosion-proof version.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Cost-effective insertion-type device
  • Housing removable under process conditions
  • Permanent readings in any position
  • With dial or linear scale with up to two alarm positions
  • High reliability and repeatability (±3% of switching point)
  • Wide range of wetted parts materials
  • With optional stainless steel housing
  • Individually calibrated and tested
  • Installation independent of pipe diameter

DW 183

The DW 183 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It

The DW 183 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The device comes with flanged connections, sizes ranging from DN65…200 and 3…8″. The measuring tube and connection is made of stainless steel (1.4404 / 316 L). There are two types of indicator available for this variant: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial.

The DW 183 is particularly suitable for flow detection in various applications that don’t require high accuracy. It can deal with flows of up to 250,000

Overview

The DW 183 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The device comes with flanged connections, sizes ranging from DN65…200 and 3…8″. The measuring tube and connection is made of stainless steel (1.4404 / 316 L). There are two types of indicator available for this variant: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial.

The DW 183 is particularly suitable for flow detection in various applications that don’t require high accuracy. It can deal with flows of up to 250,000

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Cost-effective inline device
  • Housing removable under process conditions
  • Permanent readings in any position
  • With dial or linear scale with up to two alarm positions
  • High reliability and repeatability (±3% of switching point)
  • Wide range of wetted parts materials
  • With optional stainless steel housing
  • Individually calibrated and tested

DW 182

The DW 182 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It

The DW 182 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The flow controller comes with flanged connections (DN15…65 / 1⁄2…21⁄2″). The measuring tube and connection is made of stainless steel (1.4404 / 316 L). Two types of indicator are available: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial.

The DW 182 is particularly suitable for cost-effective flow detection in various applications that don’t require high accuracy. It can deal with flows of up to 30,000 l/h or 132.09 GPM (US). There is also a high-temperature version on offer for operating conditions up to +300°C / +570°F. The DW 182 is available as non-hazardous, intrinsically safe or explosion-proof.

Overview

The DW 182 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The flow controller comes with flanged connections (DN15…65 / 12…212″). The measuring tube and connection is made of stainless steel (1.4404 / 316 L). Two types of indicator are available: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial.

The DW 182 is particularly suitable for cost-effective flow detection in various applications that don’t require high accuracy. It can deal with flows of up to 30,000 l/h or 132.09 GPM (US). There is also a high-temperature version on offer for operating conditions up to +300°C / +570°F. The DW 182 is available as non-hazardous, intrinsically safe or explosion-proof.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Cost-effective inline device
  • Housing removable under process conditions
  • Permanent readings in any position
  • With dial or linear scale with up to two alarm positions
  • High reliability and repeatability (±3% of switching point)
  • Wide range of wetted parts materials
  • With optional stainless steel housing
  • Individually calibrated and tested

DW 181

The DW 181 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It

The DW 181 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The flow controller can have G or NPT threaded connections with sizes ranging from sup>3⁄4…2″. The measuring tube and connection are made of either bronze or stainless steel (1.4404 /316 L). Two types of indicator are available: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial.

The DW 181 is particularly suitable for cost-effective flow detection in various applications where high accuracy is not required. It can deal with flows of up to 30,000 l/h or 132.09 GPM (US). There is also a high-temperature version on offer for operating conditions up to +300°C / +570°F. The DW 181 is available as non-hazardous, intrinsically safe and explosion-proof version.

Overview

The DW 181 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The flow controller can have G or NPT threaded connections with sizes ranging from sup>3⁄4…2″. The measuring tube and connection are made of either bronze or stainless steel (1.4404 /316 L). Two types of indicator are available: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial.

The DW 181 is particularly suitable for cost-effective flow detection in various applications where high accuracy is not required. It can deal with flows of up to 30,000 l/h or 132.09 GPM (US). There is also a high-temperature version on offer for operating conditions up to +300°C / +570°F. The DW 181 is available as non-hazardous, intrinsically safe and explosion-proof version.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Cost-effective inline device
  • Housing removable under process conditions
  • Permanent readings in any position
  • With dial or linear scale with up to two alarm positions
  • High reliability and repeatability (±3% of switching point)
  • Wide range of wetted parts materials
  • With optional stainless steel housing
  • Individually calibrated and tested

DWM 2000

The DWM 2000 is a 3-wire electromagnetic flowmeter to monitor the flow of conductive liquids, pastes and slurries. The range of

The DWM 2000 is a 3-wire electromagnetic flowmeter to monitor the flow of conductive liquids, pastes and slurries. The range of this insertion-type device is adjustable from 1…8 m/s or 3.3…26.2 ft/s. A welding socket is supplied as standard for welding the DWM 2000 directly onto process pipes (DN50…400 / 2…16″). The long version (DWM 2000 L) is suited for larger pipe diameters or open channels. It comes with either a threaded connection or sliding connection. Both versions are equipped with a safety chain for safe removal of the sensor and with an optional isolation valve. The flow meter is also available with VARIVENT® connection for hygienic applications.

As an alternative to insertion tubes, an optional spool piece can be used to install the DWM 2000 without welding operation. For temporarily or permanently immersed measuring points, the meter can be ordered as IP68 rated version. The DWM 2000 has an optional LCD display. Other remote display options are also available. The insertion-type flowmeter is factory calibrated before delivery.

Overview

The DWM 2000 is a 3-wire electromagnetic flowmeter to monitor the flow of conductive liquids, pastes and slurries. The range of this insertion-type device is adjustable from 1…8 m/s or 3.3…26.2 ft/s. A welding socket is supplied as standard for welding the DWM 2000 directly onto process pipes (DN50…400 / 2…16″). The long version (DWM 2000 L) is suited for larger pipe diameters or open channels. It comes with either a threaded connection or sliding connection. Both versions are equipped with a safety chain for safe removal of the sensor and with an optional isolation valve. The flow meter is also available with VARIVENT® connection for hygienic applications.

As an alternative to insertion tubes, an optional spool piece can be used to install the DWM 2000 without welding operation. For temporarily or permanently immersed measuring points, the meter can be ordered as IP68 rated version. The DWM 2000 has an optional LCD display. Other remote display options are also available. The insertion-type flowmeter is factory calibrated before delivery.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Sturdy construction: no moving parts, maintenance-free and wetted parts made of stainless steel and ceramic
  • Converter is removable or rotatable under process conditions
  • With DIP switch for setting full-scale value
  • Zero calibration button removes zero offset
  • Long sensors for open channels or pipes larger than 400 mm / 16″ in diameter
  • Optional isolation valve or welding socket for long versions (DWM 2000 L)
  • IP 68 stainless steel housing for applications where immersion can exist
  • Optional spool pieces for pipe diameters DN25…50 / 1…2″
  • VARIVENT® connection for hygienic applications
  • Indication of flow rate and flow velocity
  • With optional LCD indication or other remote display options

DWM 1000

The DWM 1000 is a 2-wire electromagnetic flow controller to monitor the flow of conductive liquids, pastes and slurries. The switching

The DWM 1000 is a 2-wire electromagnetic flow controller to monitor the flow of conductive liquids, pastes and slurries. The switching point of this insertion-type device is adjustable over a full-scale range of 0.1 …9.9 m/s or 0.3…32.5 ft/s. A welding socket is supplied as standard for welding the DWM 1000 directly onto process pipes (DN50…400 / 2…16″). The long version (DWM 1000 L) is suited for larger pipe diameters or open channels. It comes with either a threaded connection or sliding connection. Both versions are equipped with a safety chain for safe removal of the sensor and with an optional isolation valve. The flow switch is also available with a VARIVENT® connection for hygienic applications.

As an alternative to insertion tubes, an optional spool piece can be used to install the DWM 1000 without welding operation. Amplifier relays are available for a selection of AC and DC voltages. For temporarily or permanently immersed measuring points, the switch can be ordered as IP68 rated version. The DWM 1000 is factory calibrated before delivery.

Overview

The DWM 1000 is a 2-wire electromagnetic flow controller to monitor the flow of conductive liquids, pastes and slurries. The switching point of this insertion-type device is adjustable over a full-scale range of 0.1 …9.9 m/s or 0.3…32.5 ft/s. A welding socket is supplied as standard for welding the DWM 1000 directly onto process pipes (DN50…400 / 2…16″). The long version (DWM 1000 L) is suited for larger pipe diameters or open channels. It comes with either a threaded connection or sliding connection. Both versions are equipped with a safety chain for safe removal of the sensor and with an optional isolation valve. The flow switch is also available with a VARIVENT® connection for hygienic applications.

As an alternative to insertion tubes, an optional spool piece can be used to install the DWM 1000 without welding operation. Amplifier relays are available for a selection of AC and DC voltages. For temporarily or permanently immersed measuring points, the switch can be ordered as IP68 rated version. The DWM 1000 is factory calibrated before delivery.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Insertion-type flow switch
  • Sturdy construction: no moving parts, maintenance-free and wetted parts made of stainless steel and ceramic
  • Converter is removable or rotatable under process conditions
  • With DIP switch for setting full-scale value
  • Zero calibration button removes zero offset
  • Long sensors for open channels or pipes larger than 400 mm / 16″ in diameter
  • Optional isolation valve or welding socket for long versions (DWM 1000 L)
  • IP 68 stainless steel housing for immersed applications
  • Optional spool pieces for pipe diameters DN25…50 / 1…2″
  • VARIVENT® connection for hygienic applications

OPTIPROBE

The OPTIPROBE is an electromagnetic insertion-type flowmeter for flow monitoring of conductive clean liquids in water and wastewater applications. The

The OPTIPROBE is an electromagnetic insertion-type flowmeter for flow monitoring of conductive clean liquids in water and wastewater applications. The reliable and corrosion resistant flowmeter comes with different designs. Next to a basic version with fixed insertion length (Model A), the flowmeter is also available with an adjustable insertion length of up to 400 mm (Model B) that can be easily fixed and released by an integrated ball valve. This makes it the ideal flowmeter for retrofitting pipes without process interruption (hot tapping), allowing the flowmeter to be installed and removed under pressure.

The OPTIPROBE can also be an extremely flexible alternative for temporary or redundant flow measurements where extremely high accuracy is not required. It gets particularly cost-effective when used in large pipelines ≥DN200 / 8″. For temporarily or permanently flooded installations, an IP68 / NEMA 6P rated version of the OPTIPROBE can be provided. A special offshore coating or coating for burial installation is available on request. The insertion-type flowmeter offers various communication options and can be used in hazardous areas.

Overview

The OPTIPROBE is an electromagnetic insertion-type flowmeter for flow monitoring of conductive clean liquids in water and wastewater applications. The reliable and corrosion resistant flowmeter comes with different designs. Next to a basic version with fixed insertion length (Model A), the flowmeter is also available with an adjustable insertion length of up to 400 mm (Model B) that can be easily fixed and released by an integrated ball valve. This makes it the ideal flowmeter for retrofitting pipes without process interruption (hot tapping), allowing the flowmeter to be installed and removed under pressure.

The OPTIPROBE can also be an extremely flexible alternative for temporary or redundant flow measurements where extremely high accuracy is not required. It gets particularly cost-effective when used in large pipelines ≥DN200 / 8″. For temporarily or permanently flooded installations, an IP68 / NEMA 6P rated version of the OPTIPROBE can be provided. A special offshore coating or coating for burial installation is available on request. The insertion-type flowmeter offers various communication options and can be used in hazardous areas.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Wide (bi-directional) measuring range
  • All wetted parts made of non-corrosive materials
  • Also available as IP 68 / NEMA 6P rated version
  • Optional special coatings for burial installation or offshore use
  • Optimised for retrofitting in all existing pipework
  • Easier to install into large diameters as compared to inline flowmeters
  • Available as compact version or remote version with field- or wall-mounted signal converter
  • Many diagnostic functions and multilanguage settings
  • Wet calibration ex works
  • Ex approved compact version:
    • ATEX zone 2  II 3G IIC 
    • NEPSI Ex ic nA II B T3 Ge

OPTISWIRL 2100

The OPTISWIRL 2100 is a Vortex flowmeter for basic utility applications in all industries. The 2-wire device is the ideal

The OPTISWIRL 2100 is a Vortex flowmeter for basic utility applications in all industries. The 2-wire device is the ideal choice when it comes to reliable flow measurement of conductive and non-conductive liquids, (wet) gases or steam where high accuracy is not required. The flowmeter features the robust Vortex technology of the OPTISWIRL product series, but does without the high-end options of the more powerful OPTISWIRL 4200. This makes it one of the most cost-effective Vortex flowmeters in the market. This Vortex flowmeter is also equipped with the field-proven Advanced Vortex Frequency Detection (AVFD) technology for signal filtering, allowing stable measurements even under demanding process conditions.

There are different variants available for the OPTISWIRL 2100. The Vortex flowmeter comes as flange or space-saving sandwich (wafer) version. For a large measurement span even in pipelines with large diameters, a version with integrated nominal diameter reduction (F1R/F2R) can also be provided. Its remote field housing version (F) allows the signal converter to be installed up to 50 m / 164 ft away from the sensor. The Vortex flowmeter also holds approvals for use in hazardous areas.

Overview

The OPTISWIRL 2100 is a Vortex flowmeter for basic utility applications in all industries. The 2-wire device is the ideal choice when it comes to reliable flow measurement of conductive and non-conductive liquids, (wet) gases or steam where high accuracy is not required. The flowmeter features the robust Vortex technology of the OPTISWIRL product series, but does without the high-end options of the more powerful OPTISWIRL 4200. This makes it one of the most cost-effective Vortex flowmeters in the market. This Vortex flowmeter is also equipped with the field-proven Advanced Vortex Frequency Detection (AVFD) technology for signal filtering, allowing stable measurements even under demanding process conditions.

There are different variants available for the OPTISWIRL 2100. The Vortex flowmeter comes as flange or space-saving sandwich (wafer) version. For a large measurement span even in pipelines with large diameters, a version with integrated nominal diameter reduction (F1R/F2R) can also be provided. Its remote field housing version (F) allows the signal converter to be installed up to 50 m / 164 ft away from the sensor. The Vortex flowmeter also holds approvals for use in hazardous areas.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Economic flowmeter design
  • Flange or space-saving sandwich (wafer) version (up to DN100 / 4″)
  • Advanced technology for signal filtering (AVFD Advanced Vortex Frequency Detection)
  • Optional F1R/F2R version enables cost-saving installation without expensive pipeline reduction
  • Available as compact (C) or remote field (F) version
  • Robust construction (I66/67)
  • High-resolution graphical display turnable in 90° steps
  • Alternative operation using bar magnet while housing is closed
  • HART®7 communication protocol
  • Ex ia, Ex d approvals

Cone flowmeter

The cone flowmeter is a differential pressure (DP) flowmeter specifically engineered for applications with high accuracy requirements and disturbed flow

The cone flowmeter is a differential pressure (DP) flowmeter specifically engineered for applications with high accuracy requirements and disturbed flow profiles in confined installation spaces. The cone meter body can be installed with 3D/2D straight upstream/downstream pipe length and is suitable for almost any application from natural gas to steam to liquid hydrocarbons. KROHNE offers the complete cone flow metering assembly with the flow element, DP transmitter, accessories, engineering, testing and documentation from one single source.

The cone is installed in the centre of the measuring tube forcing the fluid through an annular gap. A controlled turbulence region behind the cone flattens the incoming irregular velocity profile and induces a stable differential pressure that is sensed by a downstream centre tap. Designed according to ISO 5167-5 the effect of disturbed flow profiles is eliminated and high accuracies can be achieved even with short straight pipe length. The calculated flow coefficient has an uncalibrated uncertainty of < ±5% of measured value as defined in the ISO 5167-5. KROHNE typically supplies cone meters with uncertainties of < ±0.3% calibrated on fully accredited hot water calibration facilities.

The sophisticated OPTIBAR DP 7060 or the OPTIBAR DP 3050 DP transmitter is the perfect companion for this DP flowmeter solution. Both are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Overview

The cone flowmeter is a differential pressure (DP) flowmeter specifically engineered for applications with high accuracy requirements and disturbed flow profiles in confined installation spaces. The cone meter body can be installed with 3D/2D straight upstream/downstream pipe length and is suitable for almost any application from natural gas to steam to liquid hydrocarbons. KROHNE offers the complete cone flow metering assembly with the flow element, DP transmitter, accessories, engineering, testing and documentation from one single source.

The cone is installed in the centre of the measuring tube forcing the fluid through an annular gap. A controlled turbulence region behind the cone flattens the incoming irregular velocity profile and induces a stable differential pressure that is sensed by a downstream centre tap. Designed according to ISO 5167-5 the effect of disturbed flow profiles is eliminated and high accuracies can be achieved even with short straight pipe length. The calculated flow coefficient has an uncalibrated uncertainty of < ±5% of measured value as defined in the ISO 5167-5. KROHNE typically supplies cone meters with uncertainties of < ±0.3% calibrated on fully accredited hot water calibration facilities.

The sophisticated OPTIBAR DP 7060 or the OPTIBAR DP 3050 DP transmitter is the perfect companion for this DP flowmeter solution. Both are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Cone flowmeter according to ISO 5167-5
  • Suitable for accurate flow measurement with restricted available straight pipe length
  • Large choice of wetted materials available e.g. 316L, Alloy C276, Alloy 625, Alloy 400, Duplex etc., others on request
  • Manufacturing and calibration capabilities up to 48″
  • Reduced TCO due to minimised need for recalibration in the field through advanced 3-D linearised OPTIBAR DP transmitters
  • Complete flowmeter solution with DP flow element, valves, manifold, DP transmitters, sizing, testing and documentation from a single source
  • Redundancy available (1oo2, 2oo3)
  • HART®7, Foundation fieldbus and Profibus-PA communication options
  • SIL 2/3 certified versions
  • Ex ia, Ex d approvals
  • International references with renowned EPCs

Wedge flowmeter

The wedge flowmeter is designed for difficult applications where other flow technologies fail or have a very limited-service life. It

The wedge flowmeter is designed for difficult applications where other flow technologies fail or have a very limited-service life. It can cope with high viscosities, abrasive solids-containing fluids or liquids with a tendency to scaling or agglomeration. The materials can pass the wedge restriction where other flow devices lead to material build-up in a kind of “damming” effect. Due to these advantages the wedge flowmeter has been established as a standard device in particularly difficult applications with harsh process conditions such as refineries where solid coke can pass the flowmeter along with the hot feed flow or in oil production and mining where solids are not yet separated from the stream.

KROHNE offers the complete wedge flowmeter with the wedge element, DP transmitter(s) including diaphragm-seals, accessories, engineering, testing and documentation from a single source. The pressure tapping is typically designed as flange connection for use with diaphragm seals and can be executed redundantly if required.

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Overview

The wedge flowmeter is designed for difficult applications where other flow technologies fail or have a very limited-service life. It can cope with high viscosities, abrasive solids-containing fluids or liquids with a tendency to scaling or agglomeration. The materials can pass the wedge restriction where other flow devices lead to material build-up in a kind of “damming” effect. Due to these advantages the wedge flowmeter has been established as a standard device in particularly difficult applications with harsh process conditions such as refineries where solid coke can pass the flowmeter along with the hot feed flow or in oil production and mining where solids are not yet separated from the stream.

KROHNE offers the complete wedge flowmeter with the wedge element, DP transmitter(s) including diaphragm-seals, accessories, engineering, testing and documentation from a single source. The pressure tapping is typically designed as flange connection for use with diaphragm seals and can be executed redundantly if required.

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Engineered assembly suitable for harsh flow applications with high viscosities, abrasive fluids and fluids containing solids
  • Solid materials or agglomerations can pass the flow restriction
  • Bi-directional flow measurement capabilities, no moving parts
  • Redundant versions available (1oo2, 2oo3)
  • Large choice of wetted materials for meter body and diaphragm seals
  • Manufacturing and calibration capabilities up to 48″
  • Reduced TCO due to reduced need for recalibration in the field through advanced 3-D linearised OPTIBAR DP transmitters
  • Complete flowmeter solution with wedge element, DP transmitter with diaphragm seals, flow computer, accessories, engineering, testing and documentation from a single source
  • HART®7, Foundation fieldbus and Profibus-PA communication options
  • SIL 2/3 certified versions
  • Ex ia, Ex d approvals
  • International references with renowned EPCs

Venturi flowmeter

The Venturi flowmeter is based on a classical Venturi tube, an engineered primary flow element for a most efficient and

The Venturi flowmeter is based on a classical Venturi tube, an engineered primary flow element for a most efficient and accurate differential pressure (DP) flow measurement. Thanks to its design, it has an excellent resistance to wear and doesn’t require any maintenance. The service life of the Venturi element is usually equal to the one of the entire plant. It is therefore often the ideal choice in live steam applications of power plants, wet gas flow measurement in natural gas production or CO2 injection, flow measurement of hydrocarbons and LNG as well as in gas-to-liquid processes and refineries. KROHNE offers the complete flowmeter assembly with the Venturi tube, DP transmitter, valves, accessories, engineering, testing and documentation from a single source.

Venturi tubes have one of the lowest permanent pressure loss among all primary elements, contributing to considerable energy conservation and cost savings. KROHNE offers the full range of Venturi tube designs to meet the specific application conditions. Depending on the line size and pressure rating, the Venturi tube will be made of barstock material or sheet metal. Special materials for harsh conditions are available as full material option or often also as cost-effective plasma surface coatings. Special constructions such as redundant tappings, inlet/outlets runs or flow conditioners in accordance with relevant standards (ISO 5167, etc.). can also be supplied.

The throat section and all internal welding are machined to assure perfect surface conditions and flow performance. Welds are outside of the cone-throat transition which makes the construction more precise and rugged compared to standard welded designs.

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Specifications

Depending on selected device configuration

General information

Product type Flowmeter
Product positioning For the highest requirements of accuracy and long-term stability
Measurement principle Differential pressure
Nominal diameter / size DN50…1200 / 2…48

Operating conditions

Process pressure

max. 350 bar / 5077 psi

Process temperature

-175°C…+720°C /
-283°F…+1328°F

Materials

Measuring tube Austenitic stainless steel (1.4404/316L), Carbon steel (A105), Alloy steel (ASTM A182 Gr. F12), Alloy steel (ASTM A182 Gr. F22), Alloy steel (ASTM A182 Gr. F91)

Process connections

Flange connections EN (1092-1): DN50…1200
ASME (B 16.5): 2…48″
others on request
Other connections

Butt weld ends

Approvals/Standards

Certificates/Approvals Ex ATEX, IECEx, NEPSI
Certificates/Approvals Others NACE, Pressure Equipment Directive (PED), ISO/TR 11583
Certificates/Approvals Safety SIL 2/3
NAMUR compliance NE 107, NE 21, NE 43, NE 53
Design standards ASME MFC-3M, ISO 5167-4

Communication

Analogue outputs 4…20 mA
Digital outputs FOUNDATION™ fieldbus, HART®, Profibus-PA, Bluetooth

Accuracy

Reference uncertainty 0.15 …0.22 %

Flow nozzle meter

The flow nozzle meter is designed for accurate long-term stable flow measurement of liquids gases and steam, especially in high

The flow nozzle meter is designed for accurate long-term stable flow measurement of liquids gases and steam, especially in high velocity applications with the risk of erosion or cavitation. Typical applications are feedwater, steam, condensate or refined in various industries – from power plants, refineries to chemical processing facilities to oil and gas production or CCS.

Flow nozzle meters offer a low remaining pressure loss, require only short straight inlet/outlet pipe sections and have an excellent long-term stability compared to other DP flowmeters. KROHNE offers the complete flow metering solution including flow nozzle, DP transmitter, valves, accessories, engineering, testing and documentation from one single source. The flow nozzle assembly typically comes calibrated with the nozzle installed in a metering section for offering the highest accuracy.

A number of different flow nozzle types are available to meet the exact application and regulatory requirements, e.g. a throat tap long radius nozzle according to ASME PTC 6, available with flanges or butt weld pipe connections. Also calibrated meter-runs with flow conditioner, upstream and downstream pipe sections and the flow nozzle according to ASME PTC or similar standards for performance testing are available.

The sophisticated OPTIBAR DP 7060 and the OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Overview

The flow nozzle meter is designed for accurate long-term stable flow measurement of liquids gases and steam, especially in high velocity applications with the risk of erosion or cavitation. Typical applications are feedwater, steam, condensate or refined in various industries – from power plants, refineries to chemical processing facilities to oil and gas production or CCS.

Flow nozzle meters offer a low remaining pressure loss, require only short straight inlet/outlet pipe sections and have an excellent long-term stability compared to other DP flowmeters. KROHNE offers the complete flow metering solution including flow nozzle, DP transmitter, valves, accessories, engineering, testing and documentation from one single source. The flow nozzle assembly typically comes calibrated with the nozzle installed in a metering section for offering the highest accuracy.

A number of different flow nozzle types are available to meet the exact application and regulatory requirements, e.g. a throat tap long radius nozzle according to ASME PTC 6, available with flanges or butt weld pipe connections. Also calibrated meter-runs with flow conditioner, upstream and downstream pipe sections and the flow nozzle according to ASME PTC or similar standards for performance testing are available.

The sophisticated OPTIBAR DP 7060 and the OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Flowmeter assembly for high requirements of accuracy and long-term stability
  • Short straight inlet/outlet pipe section requirements and low remaining pressure drop
  • Manufacturing and calibration capabilities up to 48″
  • Special 20-point calibration at high Reynolds-numbers possible (e.g. acc. to ASME PTC)
  • Reduced TCO due to minimised need for recalibration in the field through advanced 3-D linearised OPTIBAR DP transmitters
  • Complete flowmeter solution with flow nozzle, DP transmitter, flow computer, valves, accessories, engineering, testing and documentation from one single source
  • Redundancy available (1oo2, 2oo3)
  • HART®7, Foundation fieldbus and Profibus-PA communication options
  • SIL 2/3 certified versions
  • Ex ia, Ex d approvals
  • International references with renowned EPCs

Averaging pitot tube flowmeter

The averaging pitot tube flowmeter requires the least installation effort of all DP flowmeters. It is cost-effective and suitable for

The averaging pitot tube flowmeter requires the least installation effort of all DP flowmeters. It is cost-effective and suitable for a variety of applications. Its low remaining pressure loss and bi-directional flow capabilities make it the preferred instrument for water, sea water, condensate, cooling water, crude oil, saturated and superheated steam, nitrogen, combustion gases, ventilation air and many other liquids and gases. It can also be used for dust-laden gases at high-temperatures. The KROHNE averaging pitot tube flowmeter covers big diameters, round and rectangular pipes and ducts. It requires only short straight inlet/outlet pipe sections (7D/3D). Due to the low flow profile constriction it generates only a minimal residual pressure loss.

KROHNE offers the complete DP flow solution with averaging pitot tube, valve, manifold and DP transmitter. It comes pre-assembled, ready for operation and only needs a single flange or weld-on fitting to be installed in a process line. This reduces engineering and installation efforts as well as eliminates the need for routing of impulse lines, valves and supports. Retrofit and retractable as well as pressure- and temperature-compensated versions with associated flow computing are also available. In addition, a complete automatic purge system for dust-laden gas applications can be supplied by KROHNE from a single source.

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Specifications

Depending on selected device configuration

General information

Product type Flowmeter
Product family name OPTIBAR
Product positioning For applications with liquids, gases and steam to high-temperature applications with dust-laden gases
Measurement principle Differential pressure
Measured media Liquids, Gases, Steam
Nominal diameter / size DN50…2500 / 2…100” (inne na życzenie)

Operating conditions

Process pressure

max. 0…320 bar / 4641.2 psi (gases, liquids)
max. 180 bar / 2610.7 psi (steam)

Process temperature -200…+1150°C/
-328…+2102°F

Materials

Measuring tube Austenitic alloy (2.4602/Alloy 22), Austenitic stainless steel (1.4571/316Ti), Nickel-chrome-molybdenum-tungsten alloy (2.4819/Alloy C276), Chrome molybdenum steel alloy (1.5415/16Mo3)

Process connections

Flange connections EN (1092-1): DN50…2000 (larger on request)
ASME (B 16.5): 2…80″ (larger on request)
Weld-in connections Weld-in fitting

Approvals/Standards

Certificates/Approvals Ex ATEX, IECEx, NEPSI
Certificates/Approvals Others Oxygen, ISO/TR 11583
Certificates/Approvals Safety SIL 2/3
NAMUR compliance NE 107, NE 21, NE 43, NE 53
Design standards ISO 5167

Communication

Analogue outputs 4…20 mA
Digital outputs FOUNDATION™ fieldbus, HART®, Profibus-PA, Bluetooth

Integral orifice meter run assembly

The integral orifice meter run assembly is a differential pressure flowmeter especially designed for smaller line sizes where the surface

The integral orifice meter run assembly is a differential pressure flowmeter especially designed for smaller line sizes where the surface roughness, weld seams and other geometrical imperfections have a relatively big influence on the measurement uncertainty. The DP flowmeter therefore features a minimum length of upstream and downstream pipe, reducing additional uncertainties of the installation to a minimum. It is suitable for process and allocation measurement of gases and liquids including viscous fluids, fluids with suspended solids or fluids with gas entrainment. KROHNE offers the complete orifice assembly with orifice meter run, DP transmitter, valves, accessories, engineering, and documentation. The DP flowmeter comes pressure tested and ready for commissioning.

The meter run is available in various designs and compliant with the requirements of the ISO 5167 in terms of pressure tap orientation and dimensions. It is fully machined and straightened to meet the highest dimensional expectations. If required, an additional calibration can be carried out in line with the final operating conditions. KROHNE also supplies special constructions such as redundant taps, integrated flow conditioner, certain paint specifications or advanced NDTs from one source and in accordance with relevant standards (ISO 5167, etc.).

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Specifications

Depending on selected device configuration

General information

Product type Flowmeter
Product family name OPTIBAR
Product positioning For process applications with small line sizes (down to DN15 / ¾″4)
Measurement principle Differential pressure
Measured media Liquids, Gases, Steam
Nominal diameter / size DN20…DN50 / ¾” ..2”

Operating conditions

Process pressure max. 160 bar/
2320 psi
Process temperature -130…+400°C/
-202…+752°F

Materials

Measuring tube Austenitic stainless steel (1.4404/316L), Carbon steel (A105), Alloy steel (ASTM A182 Gr. F12), Alloy steel (ASTM A182 Gr. F22), Alloy steel (ASTM A182 Gr. F91)

Process connections

Flange connections EN (1092-1): DN15…100
ASME (B 16.5): ½…2″

Approvals/Standards

Certificates/Approvals Custody transfer (CT) AGA 3
Certificates/Approvals Ex ATEX, IECEx, NEPSI
Certificates/Approvals Others Oxygen, Pressure Equipment Directive (PED), ISO/TR 11583
Certificates/Approvals Safety SIL 2/3
NAMUR compliance NE 107, NE 21, NE 43, NE 53
Design standards ISO 5167, ASME MFC-3M

Communication

Analogue outputs 4…20 mA
Digital outputs FOUNDATION™ fieldbus, HART®, Profibus-PA, Bluetooth

Accuracy

Reference uncertainty 0.15…0.22%
Calibration Volumetric calibration with hot water, Gravimetric calibration with hot water, High pressure natural gas calibration

Compact orifice plate flowmeter

The compact orifice plate with OPTIBAR DP transmitter is an economic DP flowmeter for a broad range of applications – from demi-water

The compact orifice plate with OPTIBAR DP transmitter is an economic DP flowmeter for a broad range of applications – from demi-water to chemicals to steam. The integral orifice plate is a one-piece design per ISO 5167-2 or ASME MFC-3M, consisting of a compact orifice plate, a sandwich meter body, impulse lines and a connection flange. KROHNE offers the complete DP flow solution with integral orifice plate, manifold and DP transmitter. It comes pre-assembled, preconfigured and pressure tested – ready for immediate commissioning. There is absolutely no need for routing of impulse lines, valves and supports. In this way, material costs and installation efforts are significantly reduced.

Due to its versatile design, the compact orifice plate flowmeter is suitable for many industrial processes in chemical and petrochemical plants, in power generation, in the production and transport of oil or in gas processing plants. Redundant versions are available for safety related applications.

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Overview

The compact orifice plate with OPTIBAR DP transmitter is an economic DP flowmeter for a broad range of applications – from demi-water to chemicals to steam. The integral orifice plate is a one-piece design per ISO 5167-2 or ASME MFC-3M, consisting of a compact orifice plate, a sandwich meter body, impulse lines and a connection flange. KROHNE offers the complete DP flow solution with integral orifice plate, manifold and DP transmitter. It comes pre-assembled, preconfigured and pressure tested – ready for immediate commissioning. There is absolutely no need for routing of impulse lines, valves and supports. In this way, material costs and installation efforts are significantly reduced.

Due to its versatile design, the compact orifice plate flowmeter is suitable for many industrial processes in chemical and petrochemical plants, in power generation, in the production and transport of oil or in gas processing plants. Redundant versions are available for safety related applications.

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Reduced installation costs: no installation of further components such as valves, DP transmitter, impulse lines, supports
  • No external impulse lines: reduced risk of leakage
  • Standardised flow element according to ISO 5167-2
  • Low TCO due to reduced engineering, commissioning and installation costs
  • Reduced need for recalibration in the field through advanced 3-D linearised OPTIBAR DP transmitters
  • Complete flowmeter solution with compact orifice plate, manifold, DP transmitter, sizing and documentation from a single source
  • Standard material: 316/316L, other materials on request
  • Redundant versions, pressure and temperature compensated versions available
  • Redundancy available (1oo2, 2oo3)
  • HART®7, Foundation fieldbus and Profibus-PA communication options
  • SIL 2/3 certified versions
  • Ex ia, Ex d approvals

OPTISWIRL 5080

The OPTISWIRL 5080 is a Vortex flowmeter for high temperature applications up to +427°C / +800°F. The flowmeter is particularly

The OPTISWIRL 5080 is a Vortex flowmeter for high temperature applications up to +427°C / +800°F. The flowmeter is particularly designed for measurement of saturated and superheated steam above +240°C / +464°F. Other applications involve high temperature media like thermo oil or other heat transfer liquids as well as high temperature process and auxiliary gases.

The OPTISWIRL 5080 is available with flange connection or in sandwich design. It is intrinsically safe and explosion proof for use in hazardous areas. The 2-wire device offers pulse and current output (4…20 mA) with HART®.

Overview

The OPTISWIRL 5080 is a Vortex flowmeter for high temperature applications up to +427°C / +800°F. The flowmeter is particularly designed for measurement of saturated and superheated steam above +240°C / +464°F. Other applications involve high temperature media like thermo oil or other heat transfer liquids as well as high temperature process and auxiliary gases.

The OPTISWIRL 5080 is available with flange connection or in sandwich design. It is intrinsically safe and explosion proof for use in hazardous areas. The 2-wire device offers pulse and current output (4…20 mA) with HART®.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Patented, adaptive filtering and signal conditioning for increased low flow performance
  • Flange or space-saving sandwich version
  • Also available as dual version with two converters for multi-product pipelines and measurement redundancy
  • Ex ia, Ex d approvals

OPTISWIRL 4200

The OPTISWIRL 4200 is a Vortex flowmeter with integrated temperature sensor. It is best suited for flow measurement of liquids,

The OPTISWIRL 4200 is a Vortex flowmeter with integrated temperature sensor. It is best suited for flow measurement of liquids, dry or humid gases and saturated or superheated steam in supply processes (auxiliary service) and distribution networks. The device is also the optimum solution for advanced energy management systems (acc. to ISO 50001) as it can be supplied with integrated gross and net heat measurement for steam and condensate. For gas and steam measurements with varying process conditions the Vortex meter can also be equipped with an optional integrated pressure sensor.

Unlike traditional Vortex meters, the OPTISWIRL 4200 is able to combine flow, temperature and pressure measurement as well as flow calculation in just one device. This saves approx. 45% of installation costs and results in a better overall system accuracy. The flowmeter is available with flange connection or in flangeless wafer design. It can also be delivered with integrated nominal diameter reduction and as field mount version (with cable length up to 50 m / 164 ft). The OPTISWIRL 4200 is designed for use in Safety Instrumented Systems (SIS) and has approvals for operation in hazardous areas.

Overview

The OPTISWIRL 4200 is a Vortex flowmeter with integrated temperature sensor. It is best suited for flow measurement of liquids, dry or humid gases and saturated or superheated steam in supply processes (auxiliary service) and distribution networks. The device is also the optimum solution for advanced energy management systems (acc. to ISO 50001) as it can be supplied with integrated gross and net heat measurement for steam and condensate. For gas and steam measurements with varying process conditions the Vortex meter can also be equipped with an optional integrated pressure sensor.

Unlike traditional Vortex meters, the OPTISWIRL 4200 is able to combine flow, temperature and pressure measurement as well as flow calculation in just one device. This saves approx. 45% of installation costs and results in a better overall system accuracy. The flowmeter is available with flange connection or in flangeless wafer design. It can also be delivered with integrated nominal diameter reduction and as field mount version (with cable length up to 50 m / 164 ft). The OPTISWIRL 4200 is designed for use in Safety Instrumented Systems (SIS) and has approvals for operation in hazardous areas.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Flange or space-saving sandwich (wafer) version (up to DN100 / 4″)
  • Compact all-in-one device for varying process conditions
  • Integrated gross and net heat calculation for steam and hot water
  • Optional shut-off valve to allow replacement of pressure sensor without process interruption
  • Advanced technology for signal filtering (AVFD Advanced Vortex Frequency Detection)
  • Optional integrated reduction of nominal size for a large measurement span
  • Approx. 45% less installation costs compared to Vortex meter with external T and P sensors plus calculator
  • Also available as dual Vortex meter with two independent sensors and converters in one device for redundant measurement and applications with high safety requirements
  • Also available as remote version with field housing for installation of converter 50 m / 164 ft away from the sensor
  • SIL2/3 certified (for high, low or continuous mode of operation)
  • On-site verification of flowmeter with service tool OPTICHECK

VA45

The VA45 is a glass tube variable area (VA) flow meter for flow measurement of gases at low operating pressures

The VA45 is a glass tube variable area (VA) flow meter for flow measurement of gases at low operating pressures (<1 barg /<14.5 psig). The device is ideally suited for use in gas supply lines of industrial ovens, forges and furnaces or protective gas and heating systems (with process temperatures up to +100°C / +212°F).

The VA 45 operates without auxiliary power supply. The glass measuring cone, protected by a metal sleeve with a viewing glass, makes it easy to directly read the flow and to observe the medium. The standard version is available with flange, thread or hose connections.

Overview

The VA45 is a glass tube variable area (VA) flow meter for flow measurement of gases at low operating pressures (<1 barg /<14.5 psig). The device is ideally suited for use in gas supply lines of industrial ovens, forges and furnaces or protective gas and heating systems (with process temperatures up to +100°C / +212°F).

The VA 45 operates without auxiliary power supply. The glass measuring cone, protected by a metal sleeve with a viewing glass, makes it easy to directly read the flow and to observe the medium. The standard version is available with flange, thread or hose connections.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Simple, low-cost measuring principle without auxiliary power
  • For direct reading of the flow and observation of the medium
  • Full scale value for gases: 2300…75,000 l/h / 85…2790 SCFH
  • Maximum measuring error: ±2.5% (acc. to VDI/VDE 3513-2) or ±2% of full scale
  • Turndown ratio: 10:1

VA40

The VA40 is a glass tube variable area (VA) flowmeter for flow measurement of liquids and gases. The all-purpose flowmeter

The VA40 is a glass tube variable area (VA) flowmeter for flow measurement of liquids and gases. The all-purpose flowmeter is suitable for all basic applications up to +100°C / +212°F and max. 10 bar / 145 psi. Typical applications include flow measurement of flushing, purging or inert gases or heating and cooling circuits.

The VA40 operates without auxiliary power supply. The measuring cone, protected by a metal sleeve with a viewing glass, makes it easy to directly read the flow and to observe the medium. The VA meter can also be equipped with two optional limit switches (MIN/MAX) or analogue output (4…20 mA). The flowmeter comes with many process connections and can be used in hazardous areas.

Overview

The VA40 is a glass tube variable area (VA) flowmeter for flow measurement of liquids and gases. The all-purpose flowmeter is suitable for all basic applications up to +100°C / +212°F and max. 10 bar / 145 psi. Typical applications include flow measurement of flushing, purging or inert gases or heating and cooling circuits.

The VA40 operates without auxiliary power supply. The measuring cone, protected by a metal sleeve with a viewing glass, makes it easy to directly read the flow and to observe the medium. The VA meter can also be equipped with two optional limit switches (MIN/MAX) or analogue output (4…20 mA). The flowmeter comes with many process connections and can be used in hazardous areas.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Simple, low-cost measuring principle without auxiliary power
  • For direct reading of the flow and observation of the medium
  • Optional MIN/MAX flow switches (SIL 2 conform acc. to IEC 61508-2) or 4…20mA for recording and control
  • Full scale value for liquids: 0.4…10,000 l/h / 0.1…2,650 GPH
  • Full scale value for gases: 7…310,000 l/h / 0.25…11,000 SCFH
  • Maximum measuring error: ±1% (acc. to VDI/VDE 3513-2) or ±1% of full scale
  • Turndown ratio 10:1
  • Use in hazardous areas
  • Suitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)
  • Available as food and pharmaceutical variant (with FDA compliant materials)

DK46/47/48/800

The DK46/47/48/800 is a variable area (VA) flowmeter for monitoring and adjusting extremely small flow rates of liquids (from ≥0.04

The DK46/47/48/800 is a variable area (VA) flowmeter for monitoring and adjusting extremely small flow rates of liquids (from ≥0.04 l/h or ≥0.1 GPH) and gases (from ≥5 Nl/h or 0.22 SCFH). It is thus particularly useful for sample flow monitoring in analyser systems and gas chromatographs or measuring liquids and gases in laboratories and pilot installations. Blinds and supports are available for panel mounting to purge panels or similar applications. By using a lab support, the flowmeters can be converted into a desktop unit.

The purgemeter operates without auxiliary power supply and is available with different glass tube and installation lengths from 90 to 325 mm / 3.55 to 12.8″. The medium is visible and the flow value can be read directly off the scale at the height of the float. The glass flowmeter can be provided with max. two limit switches (NAMUR) or a 3-wire digital output. For precise setting of the flow value, the VA meter features a needle valve. The DK 46/47/48/800 is also available with a differential pressure/flow regulator to provide constant flow rates in case of varying inlet or outlet pressures. The device has approvals for use in hazardous areas.

Overview

The DK46/47/48/800 is a variable area (VA) flowmeter for monitoring and adjusting extremely small flow rates of liquids (from ≥0.04 l/h or ≥0.1 GPH) and gases (from ≥5 Nl/h or 0.22 SCFH). It is thus particularly useful for sample flow monitoring in analyser systems and gas chromatographs or measuring liquids and gases in laboratories and pilot installations. Blinds and supports are available for panel mounting to purge panels or similar applications. By using a lab support, the flowmeters can be converted into a desktop unit.

The purgemeter operates without auxiliary power supply and is available with different glass tube and installation lengths from 90 to 325 mm / 3.55 to 12.8″. The medium is visible and the flow value can be read directly off the scale at the height of the float. The glass flowmeter can be provided with max. two limit switches (NAMUR) or a 3-wire digital output. For precise setting of the flow value, the VA meter features a needle valve. The DK 46/47/48/800 is also available with a differential pressure/flow regulator to provide constant flow rates in case of varying inlet or outlet pressures. The device has approvals for use in hazardous areas.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Cost-effective small purgemeter
  • Low-cost measuring principle without auxiliary power
  • Maximum measuring error: ±1 / ±2.5 / ±4% (acc. to VDI/VDE 3513-2) or ±1 / ±2 / ±3% of full scale
  • Fine metering of very small volumes of liquids and gases
  • Integrated high quality needle valve in foot or head piece
  • Stainless steel, brass or PVDF fittings
  • Suitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)
  • No wearing parts

DK32/34

The DK32/34 is a variable area (VA) flowmeter for measuring low flow rates of liquids and gases. The tried and

The DK32/34 is a variable area (VA) flowmeter for measuring low flow rates of liquids and gases. The tried and tested meter is particularly suitable for flow monitoring and dosing in gas analyser systems or on purge panels. Due to its robust all-metal design it can also be used in difficult process conditions with temperatures up to +200°C / +392°F or pressures up to 400 barg / 5800 psig. It is available with a metering valve as standard to accurately set the flow value.

The DK32/34 operates without auxiliary power supply. It features a local indication with optional MIN/MAX limit switches (NAMUR), a reed contact or analogue output (4…20 mA). To provide constant flow rates in case of variable inlet or outlet pressures, the VA meter is also available with flow regulators. It comes with horizontal or vertical process connections for NPT or G thread, flange adapters and many other connection options. The VA meter has various approvals for hazardous areas and is suitable for use in Safety Instrumented Systems (SIS).

Overview

The DK32/34 is a variable area (VA) flowmeter for measuring low flow rates of liquids and gases. The tried and tested meter is particularly suitable for flow monitoring and dosing in gas analyser systems or on purge panels. Due to its robust all-metal design it can also be used in difficult process conditions with temperatures up to +200°C / +392°F or pressures up to 400 barg / 5800 psig. It is available with a metering valve as standard to accurately set the flow value.

The DK32/34 operates without auxiliary power supply. It features a local indication with optional MIN/MAX limit switches (NAMUR), a reed contact or analogue output (4…20 mA). To provide constant flow rates in case of variable inlet or outlet pressures, the VA meter is also available with flow regulators. It comes with horizontal or vertical process connections for NPT or G thread, flange adapters and many other connection options. The VA meter has various approvals for hazardous areas and is suitable for use in Safety Instrumented Systems (SIS).

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Simple, low-cost installation: Able to measure and display without auxiliary power supply
  • Purgemeter with 2 optional limit switches for flow monitoring
  • Various stainless steel and alloy sensor materials
  • Optional surface passivation with SilcoNert®2000 for trace-level analysis
  • Ingress protection IP65/66
  • Full scale value for liquids: 1.6…150 l/h / 0.4…40 GPH
  • Full scale value for gases: 16…4,800 l/h / 0.6…170 SCFH
  • Turndown ratio 10:1
  • Maximum measuring error: ±4% (acc. to VDI/VDE 3513-2) or ±3% of full scale
  • Suitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)
  • Approved for hazardous areas

DK37 M8

The DK37 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indicator with

The DK37 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indicator with two optional limit switches. The versatile all-metal measuring device is suitable for flow measurement of gases and liquids. Due to its sturdy design, the VA meter can be used at temperatures up to +200°C / +392°F or pressures up to 220 barg / 3190 psig. It is fitted with a needle valve as standard to accurately set the flow value.

The DK37 M8 comes with vertical or horizontal process connections for NPT or G thread, flange adapters and many other connection options. To provide constant flow rates in case of variable inlet or outlet pressures, the VA meter is also available with flow regulators. It has approvals for hazardous areas and is suitable for use in Safety Instrumented Systems (SIS).

Overview

The DK37 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indicator with two optional limit switches. The versatile all-metal measuring device is suitable for flow measurement of gases and liquids. Due to its sturdy design, the VA meter can be used at temperatures up to +200°C / +392°F or pressures up to 220 barg / 3190 psig. It is fitted with a needle valve as standard to accurately set the flow value.

The DK37 M8 comes with vertical or horizontal process connections for NPT or G thread, flange adapters and many other connection options. To provide constant flow rates in case of variable inlet or outlet pressures, the VA meter is also available with flow regulators. It has approvals for hazardous areas and is suitable for use in Safety Instrumented Systems (SIS).

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Simple, low-cost installation: Able to measure and display without auxiliary power supply
  • Purgemeter with 2 optional limit switches or 4…20mA/HART® for flow monitoring
  • Various stainless steel and alloy sensor materials
  • Optional surface passivation with SilcoNert®2000 for trace-level analysis
  • PPS housing as standard, stainless steel housing as option
  • Ingress protection IP66/67
  • Full scale value for liquids: 1.6…250 l/h / 0.4…67 GPH
  • Full scale value for gases: 16…8,000 l/h / 0.6…300 SCFH
  • Turndown ratio 10:1
  • Maximum measuring error: ±2.5% (acc. to VDI/VDE 3513-2) or ±2% of full scale
  • Suitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)
  • Approved for hazardous areas

H250 M8

The H250 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indication with

The H250 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indication with two optional limit switches. The compact flowmeter allows space-saving installation. It is thus highly suitable for installation in limited spaces.

The H250 M8E version features magnetic sensors recording the position of the float without contact or hysteresis. Standard system operation is with a linear analogue output in 2-wire technology (4…20 mA). The H250 M8M version operates without auxiliary power. The flow value as well as the optional two limit switch setpoints are displayed on the scale. It has approvals for use in hazardous areas and comes with a wide range of process connections.

Overview

The H250 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indication with two optional limit switches. The compact flowmeter allows space-saving installation. It is thus highly suitable for installation in limited spaces.

The H250 M8E version features magnetic sensors recording the position of the float without contact or hysteresis. Standard system operation is with a linear analogue output in 2-wire technology (4…20 mA). The H250 M8M version operates without auxiliary power. The flow value as well as the optional two limit switch setpoints are displayed on the scale. It has approvals for use in hazardous areas and comes with a wide range of process connections.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • The space-saving standard VA meter
  • PPS housing as standard, stainless steel housing as option
  • Optional limit switches or 2-wire 4…20mA
  • Ingress protection IP66/67
  • Full scale value for liquids: 10…6,300 l/h / 5…1664 GPH
  • Full scale value for gases: 0.7…180 m3/h / 25…111 SCFH
  • Turndown ratio 10:1
  • Maximum measuring error: ±2.5% (acc. to VDI/VDE 3513-2) or ±2% of full scale
  • Approvals for use in hazardous areas