TST90 Modular RTD thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly (paired)
threaded process connection
with neck
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
welded protection tube
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
9,0 mm (0,35”)
-
Max. immersion length on request
up to 4.000,00 mm (157,48”)
-
Material protection tube/ thermowell
1.4571 (316Ti)
-
Optional coating
Not defined
-
Process connection
male thread:
G1/2″ -
Tip shape
straight
tapered -
Surface roughness Ra
Not defined
-
Operating temperature range
PT 100:
-40 °C …120 °C
(-40 °F …248 °F) -
Max. process pressure (static)
at 20 °C: 50 bar (725 psi)
-
Accuracy
+/- 0.05 K (refering to delta-T)
-
Response time
depending on configuration
t50 = 10 s
t90 = 31 s -
Integration head transmitter
no
Field of application
The thermometer is mainly used in the chemical industry but also finds its use in other branches. The device is used for high-precision measurement of temperaturedifferences with matched sensor pairs. A variety of dimensions offers flexible application possibilities.
Universally usable for thermal energy measurements
Measuring range: -200 to +600 °C (-328 to 1112 °F)
Sensors in matched pairs within the range:0 to 120 °C (±0.05 K)–40 to 0 °C (±0.1 K)
Protection class: up to IP68
Benefits
Fast replaceability of the insertHigh degree of insert compatibility and design as per DIN 43772Fast response time with reduced tip
TST602 RTD thermometer, surface measurement
Suitable for the temperature measurement of pipe surfaces or container walls
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
cable probe
suitable for high process pressures
surface mounting -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
Not defined
-
Max. immersion length on request
up to 10.000,00 mm (393,70”)
-
Process connection
surface mounting
-
Operating temperature range
PT 100:
-20 °C …200 °C
(-4 °F …392 °F) -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
-
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
depending on configuration
Field of application
Simple, fast and retrofit installation directly on the pipe or container wall, independent from the process connection, leads to a wide choice of applications: Verifying other measurement devices or temporary temperature measurement without interrupting the process. It is specially designed for climatization and general application in building automation and heat exchangers.
TST602 RTD thermometer is a general purpose thermometer for surface measurements. It is suitable for application on flat surfaces or pipes and is specially designed for climatization and general application in building automation and heat exchangers.
Benefits
Suitable for high process pressures (no direct contact with the process)Field of application in heavy duty industrial processes
TSC310 Thermocouple sensor, cable probe
Cost efficient thermocouple sensor designed for use in many process and laboratory applications
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
cable probe
suitable for hazardous areas
process connection as compression fitting -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
2,0 mm (0,08”)
3,0 mm (0,12”)
4,5 mm (0,18”)
6,0 mm (0,24”) -
Max. immersion length on request
up to 100.000,00 mm (3.937,01”)
-
Material protection tube/ thermowell
1.4401 (316)
Alloy 600 (2.4816) -
Process connection
compression fitting:
G1/4
G3/8
G1/2
G1/8
NPT1/4
NPT1/2
NPT1/8
NPT3/8 -
Tip shape
straight
-
Operating temperature range
Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 750 °C
(max. 1.382 °F) -
Max. process pressure (static)
at 20 °C: 25 bar (363 psi)
-
Accuracy
class 2 acc. to IEC 60584
-
Response time
t50 = 1 s
t90 = 2 s -
Integration head transmitter
no
-
Ex – approvals
ATEX II
NEPSI
IECEx
UKCA -
Certification
Gost Metrology
Field of application
The thermocouple (TC) cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid medium like air, water, oil, etc. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables to detect rapid temperature changes fast and accurate.
The resistance thermometer is specially suited to temperature measurement in machinery, power stations and plants in gaseous or liquid media like air, steam, water and oil.
Benefits
High flexibility through user-specific insertion lengths and variable process connectionsFast response timeDifferent types of thermocouples according to DIN EN 60584 and ASTM E230/ANSI MC96.1: type J (Fe-CuNi), type K (NiCr-Ni)Types of protection for use in hazardous locations: Intrinsic Safety (Ex ia) and non-Sparking (Ex nA)NEPSI approval (Ex ia)
TR65 Explosion-proof Pt100 Thermometer
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
without neck -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
3,0 mm (0,12”)
6,0 mm (0,24”) -
Max. immersion length on request
up to 30.000,00 mm (1.181,10”)
-
Material protection tube/ thermowell
1.4404 (316L)
-
Process connection
male thread:
NPT1/2″
NPT3/4″
M20x1,5
compression fitting:
NPT1/2″
NPT3/4″ -
Tip shape
straight
-
Surface roughness Ra
Not defined
-
Operating temperature range
PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) -
Max. process pressure (static)
at 20 °C: 80 bar (1.160 psi)
-
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
t50 = 2 s
t90 = 5 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
ATEX II 2 GD Ex d IIC
ATEX II 3 G Ex nA IIC T6, II3D
IECEx Ex ia IIC T6 Ga/Gb
IECEx Ex d IIC T6/T5/T4
IECEx Ex d IIC T6/T5/T4, Ex tD A21
EAC Ex ia IIC T6 Ga + DIP
EAC Ex d IIC T6 Gb + DIP
NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
NEPSI Ex d IIC T6
NEPSI Ex nA IIC T6
Explosion proof -
Certification
Gost Metrology
SIL (transmitter only)
Field of application
The robust thermometer designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The sensor may be used in direct contact without thermowell or where the application requires it, spring load inside of a separate thermowell. Flexible configuration possible.
Fine Chemicals
Petrochemical industry
Power stations
Environmental engineering
Measuring range: -200 to +600 °C (-328 to 1112 °F)
Static pressure range up to 75 bar dependent on the used process connection
Protection class: IP68
Benefits
Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), flameproof (Ex d), non-sparking (Ex nA)High degree of insert compatibility and design as per DIN 43772High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
TR15 Modular RTD thermometer
Robust temperature measurement technology especially for gas and steam applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
flanged process connection or weld in
with neck
incl. thermowell (metal)
usable with insert StrongSens -
Thermowell / protection tube
bar stock (drilled)
without thermowell -
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
18,0 mm (0,71”)
24,0 mm (0,94”)
26,0 mm (1,02″) -
Max. immersion length on request
up to 30.000,00 mm (1.181,10”)
-
Material protection tube/ thermowell
1.0460 (A105)
1.4571 (316Ti)
1.7335 (13CrMo4-5; F-11)
Alloy C276 (2.4819)
Duplex SAF 2205 (1.4462)
Titan Gr2 (3.7035 )
16Mo3 (1.5415) -
Optional coating
Not defined
-
Process connection
weld in version
flange:
DN25 PN40 B1 (EN1092)
DN40 PN40 B1(EN1092)
DN50 PN40 B1 (EN1092)
ASME 1″ 150 RF (B16.5)
ASME 1″ 300 RF (B16.5) -
Tip shape
tapered
-
Surface roughness Ra
0,8 μm (31,5 μin.)
1,6 μm (63,0 μin.) -
Operating temperature range
PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) -
Max. process pressure (static)
at 20 °C: 400 bar (5.802 psi)
-
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
ATEX II1G Ex ia IIC T6
ATEX II 3 G Ex nA IIC T6, II3D
NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
IECEx Ex ia IIC T6 Ga/Gb
UK II1D Ex ia IIIC Da, II1G Ex ia IIC T6 Ga
UK II1/2D Ex ia IIIC Da/Db, II1G Ex ia IIC T6 Ga
UK II1G Ex ia IIC T6 Ga
UK II 3 G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc
EAC Ex ia IIC T6 Ga + DIP
NEPSI Ex nA IIC T6 -
Certification
Gost Metrology
SIL (transmitter only)
Field of application
The robust thermometer is designed for use in demanding applications like gas or steam applications e.g. in the Chemical, Oil & Gas and Energy industry. Highest pressures as well as high temperature can be handled by the use of robust protection tubes and special process connections. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors.
Universal range of application
Particularly suitable for steam and gas applications with high process pressures and temperatures
Measuring range: -200 to +600 °C (-328 to 1112 °F)
Static pressure range up to 400 bar (5800 psi)
Degree of protection: up to IP68
Benefits
High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengthsHigh degree of insert compatibility and design as per DIN 43772Extension neck to protect the head transmitter from overheatingFast response time with reduced/tapered tip formTypes of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), non-sparking (Ex nA)Head transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™
iTEMP TMT85 Temperature head transmitter
Transformation of sensor signals into standardized digital output signals for all industries
-
Measuring principle
Head transmitter
-
Input
2 x RTD, TC, Ohm, mV
-
Output
FOUNDATION Fieldbus H1
-
Auxiliary power supply
9…32 V DC (FOUNDATION Fieldbus)
9…17,5 V DC (FISCO/FNICO) -
Communication
FOUNDATION Fieldbus H1
-
Installation
Terminal head form B
-
Accuracy
(Pt100) <= 0,1 K
(Pt100) <= 0,18 °F -
Galvanic isolation
yes
-
Certification
ATEX II3G Ex ic IIC T6 Gc
ATEX II1G Ex ia IIC T4/T5/T6
ATEX II3G Ex nA IIC T6 Gc
ATEX II3D Ex tc IIIC Dc
ATEX II1G Ex ia IIC T6 Ga, II3D
ATEX II3G Ex nA IIC T6 Gc, II3D
ATEX II2G Ex d T6, II2D Ex tb IIIC
FM+CSA IS, NI I/1+2/ABCD
CSA C/US General Purpose
FM IS, NI I/1+2/ABCD
CSA IS, NI I/1+2/ABCD
CSA XP, NI, DIP I, II, III/1+2/A-G
NEPSI Ex ia IIC T4/T5/T6
NEPSI Ex ec IIC T4/T5/T6
TIIS Ex ia IIC T6
IECEx Ex ia IIC T4/T5/T6
FM XP, NI, DIP I, II, III/1+2/A-G
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
IECEx Ex tb IIIC Db
IECEx Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex ia [ia Ga] IIC T6 Gb
INMETRO Ex d T6 Gb, Ex tb IIIC Db
NEPSI Ex d IIC T6 Gb
UK II2D Ex tb IIIC Db
UK II3D Ex tc IIIC Dc
UK II1G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
ATEX IECEx II1G Ex ia IIC T6 Ga
FM+CSA IS, NI I/1+2/ABCD + ATEX IECEx II1G Ex ia IIC T6 Ga
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using FOUNDATION Fieldbus™ communication. High measurement point availability by means of sensor monitoring functions and device hardware fault recognition. Optimization of the measurement accuracy by sensor-transmitter matching.
2 universal input channels and FF™ protocol for the conversion of input signals into digital output signalsThe device stands out due to signal reliability, long-term stability, high precision and advanced diagnostics (important in critical processes)For the highest level of safety, availability and risk reductionInstallation in flat-face terminal head as per DIN EN 50446Optional installation in field housings even for use in Ex d areas – with mounting brackets for wall or pipe mounting
Benefits
Easy and standardized communication via FOUNDATION Fieldbus™ H1Straightforward design of measuring points in Ex-areas through FISCO/FNICO conformity in accordance with IEC 600079-27Safe operation in hazardous areas thanks to international approvals such as FM IS, NI; CSA IS, NI; ATEX Ex ia, Ex nA for intrinsically safe installation in zone 1 and zone 2High accuracy through sensor-transmitter matchingReliable operation with sensor monitoring and device hardware fault recognitionSeveral mounting versions and sensor connection combinationsRapid no-tools wiring due to optional spring terminal technology
iTEMP TMT84 Temperature head transmitter
Transformation of sensor signals into standardized digital output signals for all industries
-
Measuring principle
Head transmitter
-
Input
2 x RTD, TC, Ohm, mV
-
Output
PROFIBUS PA
-
Auxiliary power supply
9…32 V DC (PROFIBUS PA)
9…17,5 V DC (FISCO/FNICO) -
Communication
PROFIBUS PA
-
Installation
Terminal head form B
-
Accuracy
(Pt100) <= 0,1 K
(Pt100) <= 0,18 °F -
Galvanic isolation
yes
-
Certification
ATEX II3G Ex ic IIC T6 Gc
ATEX II2D Ex tb IIIC Db
ATEX II1G Ex ia IIC T4/T5/T6
ATEX II3G Ex nA IIC T6 Gc
ATEX II3D Ex tc IIIC Dc
ATEX II1G Ex ia IIC T6 Ga, II3D
ATEX II3G Ex nA IIC T6 Gc, II3D
ATEX II2G Ex d T6, II2D Ex tb IIIC
FM+CSA IS, NI I/1+2/ABCD
CSA C/US General Purpose
FM IS, NI I/1+2/ABCD
CSA IS, NI I/1+2/ABCD
CSA XP, NI, DIP I, II, III/1+2/A-G
NEPSI Ex ia IIC T4/T5/T6
TIIS Ex ia IIC T6
NEPSI Ex nA IIC T4/T5/T6
IECEx Ex ia IIC T4/T5/T6
FM XP, NI, DIP I, II, III/1+2/A-G
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
IECEx Ex tb IIIC Db
IECEx Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex ia [ia Ga] IIC T6 Gb
INMETRO Ex d T6 Gb, Ex tb IIIC Db
NEPSI Ex d IIC T6 Gb
UK II2D Ex tb IIIC Db
UK II3D Ex tc IIIC Dc
UK II1G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
ATEX IECEx II1G Ex ia IIC T6 Ga
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using PROFIBUS® PA communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.
2 input channels and PROFIBUS® PA protocol for the conversion of input signals into digital output signals The device stands out due to signal reliability, long-term stability, high precision and advanced diagnostics (important in critical processes) For the highest level of safety, availability and risk reductionInstallation in flat-face terminal head as per DIN EN 50446Optional installation in field housings even for use in Ex d areas – with mounting brackets for wall or pipe mounting
Benefits
Easy and standardized communication via PROFIBUS® PA Profile 3.02Meets the EMC requirements as per NAMUR NE 21 and the recommendations of NE 89 with regard to temperature transmitters with digital signal processingStraightforward design of measuring points in Ex-areas through FISCO/FNICO conformity in accordance with IEC 600079-27 Safe operation in hazardous areas thanks to international approvals such as FM IS, NI, CSA IS, NI as well as ATEX Ex ia, Ex nA (Ex nL)High accuracy through sensor-transmitter matchingReliable operation with sensor monitoring and device hardware fault recognition Rapid no-tools wiring due to optional spring terminal technology
iTEMP TMT182B temperature transmitter
iTEMP TMT182B head transmitter with HART® protocol for universal use
-
Measuring principle
Head transmitter
-
Input
1 x RTD, TC, Ohm, mV
-
Output
1 x analog 4…20 mA
-
Auxiliary power supply
10…36 V DC (standard-version)
10…30 V DC (Ex-version) -
Communication
HART-protocol
-
Installation
Terminal head form B
-
Accuracy
(Pt100, -50…200 °C) <= 0,14 K
(Pt100, -58…392 °F) <= 0,25 °F -
Galvanic isolation
yes
-
Certification
ATEX II1G Ex ia IIC T6
ATEX II3G Ex ec IIC T6
ATEX II2G Ex ia IIC T6, II3D Ex ia IIIC Dc
NEPSI Ex ia IIC T6 Ga
ATEX IECEx II1G Ex ia IIC T6 Ga
Field of application
The iTEMP TMT182B temperature head transmitter is designed for applications across all process industries that require accurate temperature measurements and HART® communication. The device provides valuable additional diagnostic information and stable measurement performance, helping to improve process efficiency and stable plant operation.
Temperature transmitter with HART® communication for the conversion of various input signals into a scalable, analog 4-20 mA output signalUniversal input for resistance thermometers (RTD), thermocouples (TC), resistance transmitters (Ω), voltage transmitters (mV)Reliability, long-term stability, high precision and advanced diagnostics for safe operationsInstallation in terminal heads form B or cabinets
Benefits
Safe operation in hazardous areas; international approvalsReliable operation with continuous sensor and device monitoringDiagnostics information according to NAMUR NE 107Ready to use: pre-programmed ex-works if requiredEasy configuration with free software
iTHERM MultiSens Slim TMS21 Multipoint TC thermometer
Low invasive bendable TC multipoint thermometer for petrochemical and chemical applications
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
imperial style
easy-to-use
suitable for hazardous areas
compression fitting as process connection
without neck
light chemical processes -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
6,0 mm (0,24”)
3,2 mm (0,126″)
8,0 mm (0,31″)
9,5 mm (0,37″)
6,35 mm (1/4″) -
Max. immersion length on request
up to 13.000,00 mm (511,81”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4435 (316L)
1.4571 (316Ti)
1.4541 (321)
1.4550 (347)
Alloy 600 (2.4816) -
Process connection
Compression fitting threaded 1/4″
Compression fitting threaded 1/2″
Compression fitting threaded 3/4″
Compression fitting threaded 1″
Flange as an accessory -
Tip shape
straight
-
Operating temperature range
Type K:
max. 920 °C
(max. 1.688 °F)
Type J:
max. 440 °C
(max. 824 °F)
Type N:
max. 920 °C
(max. 1.688 °F)
Type E:
max. 510 °C
(max. 950 °F) -
Max. process pressure (static)
at 20 °C: 90 bar (1305 psi)
-
Accuracy
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1 -
Response time
t50 = 3 s
t90 = 9 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
IECEX
IECEX ATEX
ATEX
UKCA -
Certification
SIL (transmitter only)
Field of application
Specially designed for applications where small size of the probe and light weight are crucial. The TMS21 can be highly customized due to its versatility. It can monitor the temperature on a very high number of points along a line just by using one process connection. It is composed of several low diameters thermocouples protected by one overall primary tube thermowell. Two different product configurations are available, with or without flexible upper thermowell-hose (for axial centering).
Light Chemical processes
Benefits
High number of measuring points in a small diameter Low invasiveness temperature profiling probe Easy mounting and cabling
iTHERM MultiSens Linear TMS12 Multipoint RTD/TC thermometer
Modular straight TC and RTD multipoint thermometer with primary thermowell
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
imperial style
easy-to-use
suitable for hazardous areas
process connection: flanged
light chemical processes
linear sensor distribution
modular design
replaceable sensors during operation
diagnostic chamber -
Thermowell / protection tube
with one primary thermowell (for replaceable sensors and increased mechanical protection)
-
Insert / probe
mineral insulated (MI) sensors in a primary thermowell
-
Outer diameter protection tube / Insert
48,3mm (1 1/2″)
60,3mm (2″)
76,1mm (2 1/2″)
88,9mm (3″) -
Max. immersion length on request
up to 15.000,00 mm (590”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4845 (310L)
1.4301 (304)
1.4307 (304L) -
Process connection
flange:
1 1/2″ ASME/ANSI B16.5 150
…900
2″ ASME/ANSI B16.5 150
…900
3″ ASME/ANSI B16.5 150
..900
DN40 EN/DIN 1092.1 PN10
…PN150
DN50 EN/DIN 1092.1 PN10
…PN150
DN80 EN/DIN 1092.1 PN10
…PN150 -
Tip shape
straight
-
Operating temperature range
Type K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200…600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °F
(-58…752 °F) -
Max. process pressure (static)
at 20 °C: 240 bar (3481 psi)
-
Accuracy
class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA -
Response time
depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX
IECEX
UL
FM
CSA -
Certification
SIL (transmitter only)
Field of application
The iTHERM TMS12 MultiSens Linear multipoint thermometer for oil & gas and chemical applications can be customized for various scenarios in compliance with the highest safety standards. It increases process safety by creating detailed linear temperature profiles and features a diagnostic chamber to contain and monitor leakages through the primary seals. Easy process integration reduces installation time and thus maximizes plant availability.
Oil & Gas industryHeavy chemical processesPetrochemical industry
Benefits
Primary thermowell for superior mechanical strength and an easy replacement of individual inserts, which are available either with TC or RTD technology Increased safety thanks to a diagnostic chamber able to contain the process in the event of leakages through the primary seals Compliance to various safety standards (such as but not limited to ATEX, PED), electrical and Pressure Directive for easy process integration High degree of customization thanks to a modular product design for maximum flexibility, easy installation and maintenance On board electronic heat protection for long product lifetime Superior mechanical strength and sensors replaceability thanks to a primary thermowell
iTHERM MultiSens Linear TMS11 Multipoint RTD/TC thermometer
Modular straight TC and RTD multipoint with primary thermowell
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
imperial style
easy-to-use
suitable for hazardous areas
process connection: flanged
light chemical processes
linear sensor distribution
modular design
replaceable sensors during operation -
Thermowell / protection tube
with one primary thermowell (for replaceable sensors and increased mechanical protection)
-
Insert / probe
mineral insulated (MI) sensors in a primary thermowell
-
Outer diameter protection tube / Insert
48,3mm (1 1/2″)
60,3mm (2″)
76,1mm (2 1/2″)
88,9mm (3″) -
Max. immersion length on request
up to 15.000,00 mm (590”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4845 (310L)
1.4301 (304)
1.4307 (304L) -
Process connection
flange:
1 1/2 ” ASME/ANSI B16.5 150
…900
2″ ASME/ANSI B16.5 150
…900
3″ ASME/ANSI B16.5 150
..900
DN40 EN/DIN 1092.1 PN10
…PN150
DN50 EN/DIN 1092.1 PN10
…PN150
DN80 EN/DIN 1092.1 PN10
…PN150 -
Tip shape
straight
-
Operating temperature range
Type K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200…600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F) -
Max. process pressure (static)
at 20 °C: 240 bar (3481 psi)
-
Accuracy
class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA -
Response time
depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX
IECEX
UL
FM
CSA -
Certification
SIL (transmitter only)
Field of application
The iTHERM TMS11 MultiSens Linear Multipoint thermometer for oil & gas and chemical applications can be customized for various scenarios in compliance with the highest safety standards. It increases process safety by monitoring the temperature on a high number of measuring points along a line using only a single process connection. Easy process integration reduces installation time and thus maximizes plant availability.
Oil & Gas industryHeavy chemical processesPetrochemical industry
Benefits
Features a primary thermowell for superior mechanical strength and an easy replacement of individual inserts, which are available either with TC or RTD technology Easy integration with inserts according to standards as per IEC 60584, ASTM E230 and IEC 60751 Electrical and Pressure Directive compliance for an easy and fast process integration High degree of customization thanks to a modular product design for maximum flexibility, easy installation and maintenance Compliance to various protection classes for use in hazardous areas Possibility to replace individual inserts, even during operationContinuous thermowell integrity monitoring thanks to a pressure port for maximum process safety
TMR35 Hygienic compact thermometer
Compact, fast and precise for the measurement of process temperatures in hygienic applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
compact temperature probe
fast response time
hygienic design
hygienic process connection
with or without neck -
Thermowell / protection tube
without (not intended to be used with thermowell)
to be used with thermowell
incl. Tee-/elbow thermowell -
Insert / probe
pipe version, isolated wires, not flexible
-
Outer diameter protection tube / Insert
3,0 mm (0,12”)
6,0 mm (0,24”) -
Max. immersion length on request
up to 600,00 mm (23,62”)
-
Material protection tube/ thermowell
1.4404 (316L)
-
Process connection
hygienic:
conical sealing system G1/2″ (metal)
clamp connections acc. to ISO 2852 / DIN 32676
screwed pipe joint acc. to DIN 11851
Varivent -
Tip shape
straight
-
Surface roughness Ra
0,4 μm (16 μin.)
0,8 μm (32 μin.) -
Operating temperature range
PT 100:
-50 °C …200 °C
(-58 °F …392 °F) -
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
-
Accuracy
class A acc. to IEC 60751
-
Response time
t50 = 1 s
t90 = 2 s -
Integration head transmitter
no (4…20mA Signal)
-
Certification
3A
Marine approval
UL 3111-1
Field of application
With cost efficiency, optimal use of space, reliable operation, easy commissioning and hygienic design the TMR35 fulfills all the requirements in the Food & Beverage as well as in the Life Science industries. A variety of hygienic process connections leads to a high flexibility.
The TMR35 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR35 with process connections for hygienic applications.
Benefits
Small, compact design made entirely of stainless steelExtremely short response timesHighly accurate even with short insertion lengths4-wire, Pt100 or PC-programmable transmitter with 4 to 20 mA outputConfiguration and visualization with ReadWin® 2000 PC operating software, which is free of chargeBreakdown information in event of sensor break or sensor short-circuit, adjustable as per NAMUR NE43Hygienic compatible design with 3-A marking and EHEDG certification; Marine approval
iTHERM TM402 Imperial Hygienic Thermometer, US style
For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
imperial style
hygienic applications
aseptic applications
hygienic process connections
with neck -
Thermowell / protection tube
without (direct immersion)
-
Insert / probe
without exchangeable insert
-
Outer diameter protection tube / Insert
1/4” (6,35 mm)
3/8” (9,53 mm) -
Max. immersion length on request
up to 15.5″ (317,5mm)
others on request -
Material protection tube/ thermowell
316L
-
Process connection
Triclamp
Clamp-connections according to ISO2852
G3/4″ Liquiphant
G1″ Liquiphant
Varivent -
Tip shape
straight
reduced -
Surface roughness Ra
30 μin (0,76 μm)
15 μin (0,38 μm) -
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Accuracy
class A acc. to IEC 60751
-
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA, HART)
-
Certification
SIL (transmitter only)
Field of application
This iTHERM thermometer has been designed to meet the basic requirements of the Food & Beverages and Life Sciences industries at the best price. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. The device uses basic technology with features such as a fixed, non-replaceable insert, a wide range of process connections and international certification at an excellent value for money.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Measuring range: –50 to +200 °C (–8 to +392 °F)
Pressure range up to 40 bar (580 psi)
Protection class: up to IP69K
Can be used in non-hazardous areas
Benefits
Excellent value for money and fast delivery User-friendly and reliable from product selection to maintenance International certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of Suitability Wide range of process connections
iTHERM TM401 Modular RTD thermometer – basic technology
For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
hygienic applications
aseptic applications
hygienic process connections
with neck -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
without exchangeable insert
-
Outer diameter protection tube / Insert
6,0 mm (0,24″)
8,0 mm (0,31″) -
Max. immersion length on request
up to 400 mm (15,75″)
-
Material protection tube/ thermowell
316L
-
Process connection
compression fitting
triclamp
microclamp
clamp connections acc. to ISO2852
Ingold
G3/4″ Liquiphant
G1″ Liquiphant
Varivent
SMS 1147
screwed pipe joint acc. to DIN 11851 -
Tip shape
straight
reduced -
Surface roughness Ra
0,76 μm (30 μin)
0,38 μm (15 μin) -
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Accuracy
class A acc. to IEC 60751
-
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA, HART)
-
Certification
SIL (transmitter only)
Field of application
This iTHERM thermometer has been designed to meet the basic requirements of the Food & Beverages and Life Sciences industries at the best price. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. The device uses basic technology with features such as a fixed, non-replaceable insert, a wide range of process connections and international certification at an excellent value for money.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industriesMeasuring range: –50 to +200 °C (–8 to +392 °F)Pressure range up to 50 bar (725 psi) Protection class: up to IP69KCan be used in non-hazardous areas
Benefits
Excellent value for money and fast deliveryUser-friendly and reliable from product selection to maintenanceInternational certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of SuitabilityWide range of process connections
TH15 Modular RTD thermometer, US style
Best in class temperature measurement for general applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
Industrial US style
modular temperature assembly
with extension
to be used with existing thermowell -
Thermowell / protection tube
to be used with thermowell
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
Insert 1/4” (6,35 mm)
-
Max. immersion length on request
up to 41″ (1041 mm)
others on request -
Material protection tube/ thermowell
Sensor sheath
316/316L -
Optional coating
Not applicable
-
Process connection
Schutzrohranschluss
Außen-Gewinde:
NPT1/2″
1-1/4″-18 UNEF -
Tip shape
straight
-
Surface roughness Ra
Not defined
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
class AA acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
transmitter only
FM IS
CSA IS
FM/CSA IS -
Certification
SIL (transmitter only)
Field of application
The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
The TH15 temperature sensors are RTD assemblies designed for use in all types of process industries, including harsh environments, due to their rugged design.They are made up of a measurement probe with an insulated RTD element and sheath.The sensor assemblies can be used in process industries such as:Chemicals Petrochemical Power plants Refineries Offshore platforms
Benefits
High flexibility due to modular assembly with standard terminal heads and customized immersion lengthOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications. Remove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solutionAll iTEMP® transmitters provide long term stability ≤ 0.05 % per yearFast response time with reduced/tapered tip formHead transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™
TH12 US style RTD sensor, cable probe
Cost efficient RTD sensor designed for use in the process industry or factory automation
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
US style
cable probe
process connection as compression fitting
without neck -
Thermowell / protection tube
without (not intended to be used with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
1/8” (3,18 mm)
3/16” (4,76 mm)
1/4” (6,35 mm)
3/8” (9,53 mm) -
Max. immersion length on request
up to 96″ (2439 mm)
others on request -
Material protection tube/ thermowell
Sensor sheath
316/316L -
Optional coating
Not applicable
-
Process connection
compression fitting:
NPT1/8″
NPT1/4″ -
Tip shape
straight
reduced -
Surface roughness Ra
Not defined
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
depends on configuration -
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
63% rt = 2,0 s
-
Integration head transmitter
Not applicable
Field of application
The Pt100 cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.
The TH12 temperature sensors are RTD’s designed for use in the process industry or factory automation type of environment. They are made up of a measurement probe with a RTD, insulation and sheath.Among other applications the sensors can be used on:Heat exchangersPower & recovery areasCarbon regeneration furnacesDryersFlue gasCompressor stationsProcess reactors
Benefits
High flexibility due to customized immersion lengthFast response time with reduced/tapered tip formSimplified model structure: Competitively priced, offers great value. Easy to order and reorderImproved galvanic isolation on most devices (2 kV)
TH11 Modular RTD thermometer, US style
Best in class temperature measurement technology for general applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
US style
modular temperature assembly
threaded process connection
direct immersion style -
Thermowell / protection tube
without (not intended to be used with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
1/8” (3,18 mm)
3/16”(4,76 mm)
1/4” (6,35 mm)
3/8” (9,53 mm) -
Max. immersion length on request
up to 96″ (2439 mm)
others on request -
Material protection tube/ thermowell
Sensor sheath
316/316L -
Process connection
male thread:
G1/2″
NPT1/2″
compression fitting:
NPT1/8″
NPT1/4″ -
Tip shape
straight
reduced -
Surface roughness Ra
Not defined
-
Operating temperature range
PT 100:
-200 °C …600 °C
(-328 °F …1.112 °F) -
Max. process pressure (static)
at 20°C: 250 bar (3.626 psi)
depends on configuration -
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
63% rt = 2,0 s
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
transmitter only
FM IS
CSA IS
FM/CSA IS -
Certification
SIL (transmitter only)
Field of application
The high modular thermometer is used for several applications in almost all industries. Examples are heat exchangers, dryers, process reactors , reactor stations, etc. With different head transmitter it’s a complete unit ready for use with enhanced measurement accuracy and reliability. It also enables very fast response times, due to direct contact measurement without thermowell. A variety of process connections and dimensions offer flexible application possibilities.
The TH11 temperature sensors are RTD’s designed for use in the process industry or factory automation type of environment. They are made up of a measurement probe with a RTD, insulation and sheath.Among other applications the sensors can be used on:Heat exchangersPower & recovery areasCarbon regeneration furnacesDryersFlue GasCompressor stationsProcess reactors
Benefits
High flexibility due to modular assembly with standard terminal heads and customized immersion lengthOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications. Remove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solution.All iTEMP® transmitters provide long term stability ≤ 0.05 % per yearFast response time with reduced/tapered tip formHead or field transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™
TC66 Explosion-proof TC Thermometer
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
-
Measuring principle
Thermocouple
-
Characteristic / Application
US style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
with neck
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
bar stock (drilled)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
20 mm (0,79″)
24 mm (0,94″)
25 mm (0,98″) -
Max. immersion length on request
up to 5.000,00 mm (196,85”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4404 (316L)
1.4571 (316Ti)
Alloy C276
Alloy 400 -
Optional coating
Not defined
-
Process connection
male thread:
NPT3/4″
NPT1″
flange:
ASME 1″ 150 RF (B16.5)
ASME 1″ 300 RF (B16.5)
ASME 1″ 600 RF (B16.5)
ASME 1,5″ 150 RF (B16.5)
ASME 1,5″ 300 RF (B16.5)
ASME 1,5″ 600 RF (B16.5)
ASME 2″ 300 RF (B16.5)
ASME 2″ 600 RF (B16.5) -
Tip shape
straight
tapered -
Surface roughness Ra
1,6 μm (63,0 μin.)
-
Operating temperature range
Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 800 °C
(max. 1.472 °F) -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
-
Accuracy
class 1 acc. to IEC 60584
-
Response time
depending on configuration
t50 = 3 s
t90 = 7 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II
IECEx
NEPSI
EAC Ex
Explosion proof
UKCA -
Certification
Gost Metrology
SIL (transmitter only)
Field of application
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors.
Heavy duty applications
Oil & Gas processing industry
Measuring range: –40 to 1 100 °C (–40 to 2 012 °F)
Static pressure range up to 100 bar (1450 psi)
Protection class: IP68
Benefits
Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), flameproof (Ex d), non-sparking (Ex nA)High degree of insert compatibility and design as per DIN 43772Extension neck to protect the head transmitter from overheatingHigh degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
TC65 Explosion-proof thermocouple thermometer
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
without neck -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
3,0 mm (0,12”)
6,0 mm (0,24”) -
Max. immersion length on request
up to 30.000,00 mm (1.181,10”)
-
Material protection tube/ thermowell
1.4404 (316L)
Alloy 600 (2.4816) -
Process connection
male thread:
NPT1/2″
NPT3/4″
compression fitting:
NPT1/2″
NPT3/4″ -
Tip shape
straight
tapered -
Operating temperature range
Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 800 °C
(max. 1.472 °F) -
Max. process pressure (static)
at 20 °C: 80 bar (1,160 psi)
-
Accuracy
class 1 acc. to IEC 60584
-
Response time
depending on configuration
t50 = 3 s
t90 = 7 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II
IECEx
NEPSI
EAC Ex
Explosion proof -
Certification
Gost Metrology
SIL (transmitter only)
Field of application
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The sensor may be used direct contact without thermowell or where the application requires it, spring load inside of a separate thermowell. Flexible configuration possible.
Fine Chemicals
Petrochemical industry
Power stations
Environmental engineering
Measuring range: –40 to 1 100 °C (–40 to 2 012 °F)
Static pressure range up to 75 bar dependent on the used process connection
Protection class: IP68
Benefits
Types of protection for use in hazardous locations: Intrinsic safety (Ex ia), flameproof (Ex d), non-sparking (Ex nA)High degree of insert compatibility and design as per DIN 43772High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths For plug-in/screw-in with sliding compression fitting
TAF12S High temperature TC thermometer
Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
modular temperature assembly
high temperature (furnace)
incl. single ceramic thermowell -
Thermowell / protection tube
ceramic protection tube
-
Insert / probe
ceramic capilarry, rigid
-
Outer diameter protection tube / Insert
9,0 mm (0,35”)
-
Max. immersion length on request
up to 2.500,00 mm (98,43”)
-
Material protection tube/ thermowell
Ceramic (C610/C799)
-
Process connection
compression fitting:
G1/2″
G3/4″
G1″
adjustable Flange -
Tip shape
straight
-
Operating temperature range
Type S:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type R:
0° C …1.600 °C
(32 °F …2.912 °F)
Type B:
600 °C …1.700 °C
(1.112 °F …3.092 °F) -
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
-
Accuracy
class 2 acc. to IEC 60584
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Certification
SIL (transmitter only)
Field of application
Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell made from ceramic materials serves as protection from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
The TAF12S are assemblies with single ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators. Process temperatures: up to +1700 °C (+3092 °F)
Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistanceLong term stable measurement due to sensor protection with non-porous materialsFlexible product selection by modular designOptimized life cycle costs by means of replaceable spare parts
TA414 Welded thermowell
Metric thermowell with clamp screw for simple industrial applications
-
Measuring principle
Fabricated Thermowell
-
Characteristic / Application
metric style
thermopocket for TST 414
threaded process connection -
Head connection
fixed screw
-
Maximum standard immersion length
4.000 mm (157,48″)
-
Max. immersion length on request
10.000 mm (393,7″)
-
Process connection
thread:
G1/2″ -
Thermowell root diameter
4,5 mm (0,18″)
-
Medium contact material
1.4571 (316Ti)
-
Wetted part finishing (Ra)
<1.6 µm (63.00 µin)
-
Tip shape
straight
-
Temperature range
-200…700 °C (-328…1.292 °F)
-
Max. process pressure (static)
50 bar (725 psi)
-
Max. process pressure at 400 °C
depends on process connection
Field of application
The protection tube is used to match RTD thermometers, such as TST414 from Endress+Hauser, to protect the insert from chemical corrosion. It has a locking screw to fasten the thermometer in place and allows an easy replacement of the thermometer. Due to the reduced wall thickness, it is suggested to use it in processes with slow or medium process flow velocity.
TA414 is used to match RTD thermometers, as TST414, to protect the probe from chemical corrosion. The locking screw fastens the thermometer in place and allows an easy replacement of the thermometer.Due to the reduced wall thickness, it is suggested to use TA414 in processes where no strong flow is present.
Benefits
TA414 is used to match RTD thermometers, as TST414, to protect the probe from chemical corrosionThe locking screw fastens the thermometer in place and allows an easy replacement of the thermometerDue to the reduced wall thickness, it is suggested to use TA414 in processes where no strong flow is present
T15 Explosion proof RTD thermometer, US style
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
Explosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell -
Thermowell / protection tube
to be used with thermowell
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
Not applicable
-
Max. immersion length on request
up to 100″ (2540 mm)
others on request -
Material protection tube/ thermowell
Sensor sheath
316/316L -
Optional coating
Not defined
-
Process connection
male thread:
NPT1/2″ -
Tip shape
straight
-
Surface roughness Ra
Not defined
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
Not applicable
-
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
63% rt = 3 s
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
FM XP DIP Class I,II,III Div. 1+2, Grp.A-G
FM XP NI DIP Class I,II,III Div. 1+2, Grp.A-G
CSA XP DIP Class I,II,III Div. 1+2, Grp.B-G
CSA XP NI DIP Class I,II,III Div. 1+2, Grp.B-G
FM/CSA XP DIP Class I,II,III Div. 1+2, FM Grp.A-G, CSA Grp.B-G
FM/CSA XP NI DIP Class I,II,III Div.1+2 FM Grp.A-G, CSA Grp.B-G
CSA C/US XP, DIP I, II, III/1/A-G
cCSAus General Purpose -
Certification
SIL (transmitter only)
Field of application
The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
The T15 temperature sensor is a RTD assembly designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.The sensor is made up of a measurement probe with an insulated RTD element and sheath.
The sensor assembly can be used in process industries such as:
Chemicals
Petrochemical
Refineries
Offshore Platforms
Benefits
FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safetyOne source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applicationsRemove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solutionAll iTEMP transmitters provide long term stability ≤0.05% per year
Ecograph T RSG35 Universal Graphic Data Manager
Paperless recording, visualization and monitoring of the process values at the same time
-
Measuring principle
Data manager
-
Measuring principle
Universal Graphic Data Manager
-
Function
Secure data recording made easy – Monitor, visualize, record and communicate process values – every measurement value counts!
-
Input
12 analog (max) (U, I, TC, RTD, frequency, pulse)
6 digital (max) -
Output
6 relays (max)
1 transmitter power supply -
Interface
RS232/485 (optional)
Ethernet
USB
Modbus RTU/TCP Slave (optional) -
Storage/Recording
internal memory
SD card
USB flash drive -
Display
TFT 5.7″ colour graphic display
-
Housing
panel mounting
desktop housing
field housing -
Certificates
UL recognized
CSA -
Software package
mathematics
-
Measuring principle
Electronic Data Acquisition
-
Functions
“Secure data recording and signal analysis
Visualization
Integrated web server for device set-up
E-Mail notification
100 ms scan rate
Modular design for simple expansion
Data readout and processing via Field Data Manager Software
OPC server for indication of instantaneous values (optional) -
Maximal input
“12 Analog (U, I, TC, RTD, frequency, pulse)
6 Digital” -
Maximal output
6 Relays
1 Transmitter power supply´ -
Interface
RS232/485 (optional)
Ethernet
USB
Modbus RTU Slave (optional)
Modbus TCP Slave (optional) -
Storage/Recording
Internal memory
SD card
USB flash drive -
Display
TFT 5.7″ colour graphic display
-
Housing
Panel
desktop housing
field housing -
Power supply
100…230 V AC +/-10%
24V (-10%, +15%) AC/DC -
Certification
UL
CSA GP -
Software package
Mathematics
Field of application
Safe and complete recording and visualization of all process sequences. Demands on process monitoring and data recording are becoming more and more complex. Because every measurement value counts, the Universal Data Manager Ecograph T RSG35 records, visualizes and monitors all analog or digital input signals. The unit is easy to use and comes with features to save costs and simplify data acquisition. Due to its variety of communication possibilities a simple system integration is possible.
The Ecograph T is the right solution for a wide range of applications such as:Quality and quantity monitoring in the water and wastewater industryTemperature monitoring in metal workingMonitoring of processes in power stationsDisplaying and recording of critical process parametersTank and level monitoring
Benefits
Versatile: up to 12 universal inputs record a wide range of measuring signalsClear layout: 5.7″ TFT screen for displaying measured values in a maximum of four groups, with digital, bar graph and curve displaySafe: reliable data archiving with internal memory and separate SD cardEasy: intuitive operation via the navigator (jog/shuttle dial) on site, or user-friendly operation at the PC via the integrated web serverCompact: low installation depth, saves space and moneySystem-enabled: common interfaces such as Ethernet, RS232/485, USB and optional slave function for Modbus RTU/TCPInformative: e-mail notification in event of alarms and limit violation
RNO22 output amplifier
Safe and reliable control of active components
-
Measuring principle
Active barrier
-
Measuring principle
Output isolating amplifier
-
Function
1-channel
2-channel -
Power Supply
24 V DC
-
Input
0/4…20 mA / HART
passive -
Output
0/4…20 mA / HART
active -
Certificates
ATEX IECEx II(1)G [Ex ia Ga] IIC, II(1) D [Ex ia Da] IIIC, II3G Ex ec IIC Gc
DNV -
SIL
SIL 2 SC 3
-
Operation
DIP switch, HART
Field of application
The RNO22 output isolating amplifier is used to safely control active components such as control valves, actuators, I/P converters or indicators. The intrinsically safe device separates and transmits analog 0/4 to 20 mA signals and offers bidirectional HART® transparency for digital communication with smart actuators. The compact interface device with up to two galvanically isolated channels enables open- and short-circuit monitoring for reliable operation of critical equipment.
1- or 2-channel output isolating amplifierReliable control of active components such as control valves, current-to-pressure transducersTransmission and galvanic isolation of 0/4 to 20 mA signalsIntrinsically safe [Ex-ia], installation in Ex Zone 2Suited for use in safety instrumented systems up to SIL 2 (SC 3) in accordance with IEC 61508Bidirectional transmission of digital HART® communication signalsAmbient temperature range: –40 to 70 °C (–40 to 158 °F)
Benefits
Safe and reliable control of active components in hazardous areas Quick and easy wiring and commissioning: plug-in terminals, power supply via DIN rail bus connector Compact housing: up to 2 channels on 12.5 mm (0.49 in) for efficient use of space in control cabinets Accurate and reliable signal transmission Line break and short-circuit monitoring
RLN42 NAMUR isolating amplifier
Two-channel NAMUR isolating amplifier for the transmission of binary switch signals
-
Measuring principle
Active barrier
-
Measuring principle
NAMUR isolating amplifier
-
Function
2-channel, changeover contact
-
Loop power supply
8 V DC
-
Power Supply
20…250 V AC/DC
-
Auxiliary power supply / Loop power supply
8 V DC
-
Input
NAMUR
blocking: < 1,2 mA
conducting: > 2,1 mA -
Output
relay contact
-
Certificates
ATEX IECEx II(1)G [Ex ia Ga] IIC, II(1) D [Ex ia Da] IIIC, II3G Ex ec nC IIC Gc
DNV -
SIL
SIL 2
-
Operation
DIP switch
Field of application
The NAMUR isolating amplifier is designed for safe operation of proximity switches according to EN 60947-5-6 (NAMUR) as well as open and mechanical contacts with resistive coupling elements. It has a universal power supply (24 to 230 V AC/DC) and one relay output (changeover) per channel. The device is approved for intrinsically safe (Ex i) circuits up to zone 0 (gas) and zone 20 (dust) in the Ex area. RLN42 can be used in safety equipment up to SIL 2 in accordance with IEC 61508.
Isolating amplifier for binary switch signalsWide-range power supply (24 to 230 V AC/DC)Input for proximity sensors acc. to NAMUR (EN 60947-5-6); floating contacts or contacts with resistance circuitMonitoring of input circuits for line faults such as line break and short-circuit (LFD), disengageableOutput-side relay contacts as signal output, direction of action can be selected via DIP switchesAmbient temperatures -40 to 60 °C (-40 to 140 °F)Installation in hazardous areas zone 2 / div 2
Benefits
Simple and fast wiring with pluggable terminals Suited for use in safety instrumented systems up to SIL 2 (IEC 61508) Compact housing width with 17.5 mm (0.69 in) for efficient use of space Galvanic 3-way isolation
RIA452 Process indicator with pump control
Digital process meter in panel mounted housing for monitoring and displaying analog measured values
-
Measuring principle
Indicators with control unit
-
Measuring principle
Process indicator with pump control
-
Function
Display
Power
Switch
Seperate
Convert
Count
Calculate -
Display
LCD multicolour
Illuminated
Bargraph -
Power Supply
90…250 V AC
20…28 V AC
20…36 V DC -
Input
1 x analog (U, I, RTD, TC, R)
-
Output
1 x analog (U, I)
1 x transmitter power supply -
Output
1 x analog (U, I)
1 x transmitter power supply -
Software functions
Pump control
Linearisation
Flow calculation
Batch counter -
Certificates
FM AIS I,II,III/1/ABCDEFG
CSA (Ex ia)I,II,III/1/ABCDEFG -
SIL
Not defined
-
Panel mounting
panel mounting
-
Measuring principle
Display
-
Function
Display
Power
Switch
Seperate
Convert
Count
Calculate -
Certification
UL rec. Comp
ATEX Ex i
FM USA IS
FM USA NI
CSA IS
CSA NI
TIIS Ex ia -
Input
1 x analog (U, I, RTD, TC, R)
-
Output
1 x analog (U, I)
1 x transmitter power supply -
Relay output
4…8 x changeover contacts
-
Auxiliary power supply / Loop power supply
90…250 V AC
20…28 V AC
20…36 V DC -
Dimensions (wxhxd)
Panel housing:
96 x 96 x 161.3 mm
(3.78″ x 3.78″ x 6.35″) -
Software
Pump control
Linearisation
Flow calculation
Batch counter -
Operation
3 keys
Interface RS252 + ReadWin2000 -
Display
LCD multicolour
Illuminated
Bargraph
Field of application
The process measuring device monitors and displays the analog measured values. Pumps can be monitored using the digital status inputs. The RIA452 can supply connected two-wire sensors directly with power.
The RIA452 can supply connected two-wire sensors directly with power, optionally intrinsically safe. Up to eight freely programmable relays monitor the measured value for exceeding or falling below limit values. Other operating modes for the relays are sensor or device faults, batch and pump control functions (e.g. alternating pump control). In addition, the RIA452 can be used as a preset counter and for flow measurement in open channels and measuring weirs.
Benefits
7-digit 14-segment LC display, large bar graph with overrange and underrangeDigital status inputs for pump monitoringFlow measurement for open channels and weirsIntrinsically safe input with integrated loop power supplyMin/Max value savedLinearization table with up to 32 support points
RIA16 Loop-powered indicator
Excellently readable indication of 4…20 mA signal with trend bar graph for a better process overview
-
Measuring principle
Loop powered indicators
-
Measuring principle
Loop-powered field indicator
-
Function
Display
-
Display
LCD 26 mm (1.02″)
5-digit
Bargraph
Plain text display -
Power Supply
Loop powered
-
Input
1 x analogue 4…20 mA
-
Output
1 x open collector
-
Output
1 x open collector
-
Software functions
Not defined
-
Certificates
ATEX II2(1)G Ex ib[ia] IIC T6
CSA General Purpose
CSA IS, NI/I/2/ABCDEFG/T6
FM IS, NI/I/2/ABCDEFG/T6
EAC 1Ex ib[ia] IIC T6
IECEx Ex ib[ia] IIC T6
NEPSI Ex ib[ia] IIC T6/T5/T4
UK II2(1)G Ex ib [ia Ga] IIC T6 Gb
marine certificate -
SIL
Not defined
-
Panel mounting
field
-
Measuring principle
Display
-
Function
Display
-
Certification
UR C/US
CSA GP
ATEX Ex i
FM USA NI
FM USA DIP
CSA NI
CSA DIP
Marine approval -
Input
1 x analogue 4…20 mA
-
Output
1 x open collector
-
Auxiliary power supply / Loop power supply
Loop powered
-
Dimensions (wxhxd)
Field housing:
199 x 133 x 96 mm
(7.83″ x 5.24″ x 3.78″) -
Operation
3 keys interface on electronics + PC interface FieldCare
-
Display
LCD 26 mm (1.02″)
5-digit
Bargraph
Plain text display
Field of application
The indicator shows the measured signal on the large, backlit display. A bar graph indicates the value graphically for a quick process overview. An editable plain text field displays further information like engineering unit or TAG. Limit value infringement is also signalized and an open collector can be switched. The indicator is powered directly from the 4…20 mA loop and doesn’t need a separate power supply. For applications in hazardous areas the device is available with Ex approvals.
Microcontroller controlled process indicator with field housing and illuminated LC display. The measuring range, decimal point and offset of the display can be configured comfortably by means of three keys in the device with the housing open or by means of a PC with the FieldCare PC software.
Benefits
Display of 4 to 20 mA measured values5-digit measured value display with dimension, bar graph and backlightNo external power supply requiredVersions: Fiber glass reinforced plastic respectively aluminum for Ex-applicationsEasy 3-key operation; or configuration with FieldCare PC software; or configuration without power supply using setup boxInternational approvals; marine approvalAllows the HART® transmission protocol to pass unimpeded
RIA14 Loop-powered field indicator
Excellent readable indication of a 4…20 mA signal on-site for a better process overview!
-
Measuring principle
Loop powered indicators
-
Measuring principle
Loop-powered field indicator
-
Function
Display
-
Display
LCD 20 mm (0.79″)
5-digit
Bargraph
Plain text display -
Power Supply
Loop powered
-
Input
1 x analogue 4…20 mA
-
Output
1 x open collector
-
Output
1 x open collector
-
Software functions
Not defined
-
Certificates
ATEX II2(1)G Ex ib [ia Ga] IIC T6 Gb
ATEX II2G Ex db IIC T6 Gb
ATEX II2D Ex tb IIIC Db
ATEX II3G Ex nA IIC T6
CSA General Purpose
CSA XP,NI,DIP I,II,III/1+2/ABCDEFG
FM XP,NI,DIP I,II,III/1+2/ABCDEFG
EAC 1Ex ib[ia] IIC T6
EAC 1Ex d IIC T6, Ex tD A21
IECEx Ex ib [ia Ga] IIC T6 Gb
IECEx Ex db IIC T6 Gb
IECEx Ex tb IIIC Db
NEPSI Ex ib[ia] IIC T6/T5/T4
NEPSI Ex d IIC T6/T5/T4
TIIS Ex d IIC T6
UK II2(1)G Ex ib [ia Ga] IIC T6 Gb
UK II2G Ex db IIC T6 Gb
UK II2D Ex tb IIIC Db
marine certificate -
SIL
Not defined
-
Panel mounting
field
-
Measuring principle
Display
-
Function
Display
-
Certification
UR C/US
CSA GP
ATEX Ex d
ATEX Staub
ATEX n
FM USA NI
FM USA DIP
FM USA XP
CSA NI
CSA DIP
CSA XP
Marine approval -
Input
1 x analogue 4…20 mA
-
Output
1 x open collector
-
Auxiliary power supply / Loop power supply
Loop powered
-
Dimensions (wxhxd)
Field housing:
132 x 135 x 106 mm
(5.2″ x 5.31″ x 4.17″) -
Operation
3 keys interface on electronics + PC interface FieldCare
-
Display
LCD 20 mm (0.79″)
5-digit
Bargraph
Plain text display
Field of application
The indicator shows the measured signal on the large, backlit display. An additional bar graph gives a quick process overview and a plain text field displays further information like the engineering unit or TAG. Limit value infringements are also signalized and an open collector can be switched. No separate power supply is required, the indicator is powered directly from the 4…20 mA loop. The housing is available in aluminum and in stainless steel as well as with an optional Ex d approval.
Microcontroller controlled display unit in single chamber field housing with illuminated LC display. The measuring range, decimal point and offset of the display can be configured comfortably by means of three keys in the device with the housing open or by means of a PC with the FieldCare PC software.
Benefits
Display of 4 to 20 mA measured values5-digit measured value display with dimension, bar graph and backlightNo external power supply requiredVersions: Die-cast aluminum housing or stainless steel housingEasy 3-key operation; or configuration with FieldCare PC software; or configuration without power supply using setup boxInternational approvals; marine approvalAllows the HART® transmission protocol to pass unimpeded
RB223 Loop powered passive barrier
One or two-channel barrier for the safe separation of 4…20 mA standard signal circuits
-
Measuring principle
Passive barrier
-
Measuring principle
Power supply
-
Function
Passive barrier for safe seperation of 4…20 mA current circuit
-
Loop power supply
Loop powered
-
Auxiliary power supply / Loop power supply
Loop powered
-
Input
2 x analog 4…20 mA
-
Output
2 x analog 4…20 mA
-
Certificates
ATEX II(1)GD(Ex ia)IIC
FM AIS I,II,III/1/ABCDEFG1
CSA (Ex ia) I,II,III/1/ABCDEFG1
SIL -
Operation
HART
-
Measuring principle
Power supply
-
Function
Passive barrier for safe seperation of 4…20 mA current circuit
-
Certification
CSA GP
ATEX Ex ia
CSA IS
CSA NI
SIL -
Input
2 x analog 4…20 mA
-
Output
2 x analog 4…20 mA
-
Auxiliary power supply / Loop power supply
Loop powered
-
Dimensions (wxhxd)
22.5 x 110 x 112 mm
(0.89″ x 4.33″ x 4.41″) -
Operation
HART
Field of application
The RB223 passive barrier can be used to galvanically isolate active signal circuits (0 to 20 mA) in three applications:Transmission from non-Ex to Ex areas e.g for active adjusters, controllers or indicators,Transmission from Ex to non-Ex areas for connection of active, intrinsically safe circuits to the PLC,Transmission from Ex to non-Ex areas for supply of intrinsically safe transmitters with non-intrinsically safe transmitter power supply.
Separation of active 0/4 to 20 mA signals from transmitters, valves and adjusters.
Benefits
Compact side-by-side housing for DIN railSpace-saving one-channel and two-channel versionNo power supply necessaryInternational Ex approvals; Can be used up to SIL 3Bidirectional HART® transmissionCommunication sockets for HART® + integrated HART® resistor for sensor configuration
RA33 Batch Controller
Recording and controlling of batch operations
-
Measuring principle
Application manager
-
Measuring principle
Batch controller
-
Function
Filling & dosing
-
Calculations
Volume calculation
-
Number of applications
1
-
Data storage
yes
-
Calculation standards
ASTM D1250-04
-
Communication
RS232
USB
Ethernet
Modbus TCP
Modbus RTU -
Power supply
Not defined
-
Loop power supply
Low voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%)
24 V AC (±50%) -
Protection class
IP65
-
Input
1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%) -
Output
1 x analogue (I) / pulse (active)
2 x open collector -
Dimensions (WxHxD)
144 x 144 x 103.1 mm (5.67″ x 5.67″ x 4.06″)
-
Operation
3 operation buttons and 14 function buttons for batch operation or via FieldCare
Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface)
Selectable language -
Display
160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm -
Software functions
Volume calculation
1 or 2 stage operation
Manual and automatic overrun correction
Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils -
Certificates
CE
CSA GP
NTEP (USA)
-
Measuring principle
Batch controller
-
Function
Filling & dosing
-
Certification
CE
UL listed
CSA GP -
Input
1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%) -
Output
1 x analogue (I) / pulse (active)
2 x open collector -
Relay output
2 x relay
-
Auxiliary power supply / Loop power supply
Low voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%), 24 V AC (±50%) -
Dimensions (wxhxd)
144 x 144 x 103.1 mm
(5.67″ x 5.67″ x 4.06″) -
Software
Volume calculation
1 or 2 stage operation
Manual and automatic overrun correction
Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils -
Operation
3 operation buttons and 14 function buttons for batch operation or via FieldCare
Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface)
Selectable language -
Display
160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm
Field of application
The Batch Controller RA33 is designed to record flow and control output signals for valves and pumps to ensure the exact dosing of predefined batch quantities. The measured volume can be corrected with the temperature/density compensation function. The filling process can be optimized with an automatic or fixed after-run correction. Mineral oils can be corrected according to the ASTM D1250-04 standard.
Recording and controlling of slow batch operations with a duration of longer than 10 seconds. Typical applications include:Food industry
Chemical industry
Pharmaceutical industry
Oil & gas industry
Benefits
Fixed and automatic after-run correction for constant, extremely accurate resultsHigher quality through fast and exact dosingOptional volume correction for mineral oils as per ASTM D1250-04Detailed logging of protocols (preset counter, volume counter, batch name and number) as well as error messages and changes of operating parametersStandard models are suitable for connecting and supplying all common flow transmitters, temperature sensors and density sensorsRemote control option to start and abort batch runsDaily, monthly and annual statistics on the batch run size and quantity
Servo tank gauging instrument Proservo NMS83
High precision servo measurement for liquid level, interface and density for hygienic applications
-
Measuring principle
Servo / Float Tank Gauging
-
Characteristic / Application
Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications -
Specialities
Custody transfer level measurement
Interface measurement
Spot density, density profile measurement -
Supply / Communication
85-264VAC
52-74VAC
19-64VDC -
Accuracy
up to 0.4 mm
-
Ambient temperature
Standard:
-40°C…60°C
(-40°F…140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F…131°F) -
Process temperature
-200°C…200°C
(-328°F…392°F) -
Process pressure / max. overpressure limit
6 bar abs
-
Main wetted parts
316L, AlloyC276, PTFE
-
Process connection
Flange:
DN80/3″ / DN150/6″ -
Max. measurement distance
22 m (72 ft)
-
Communication
Outputs:
Fieldbus: Modbus RS485, V1, WM550
HART, BPM and TRL/2 (via GE option)
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active) -
Certificates / Approvals
ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
INMETRO, NEPSI, UK Ex -
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103 -
Metrological approvals and certificates
OIML, NMi, PTB
-
Options
Redundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection -
Application limits
Stilling well or guide wires for turbulent
application
Recommend PTFE displacer for high
viscosity application
Interface measurement requires min. difference of 0.100 g/ml
between layers
-
Measuring principle
Servo / Float Tank Gauging
-
Characteristic / Application
Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications -
Supply / Communication
85-264VAC
-
Ambient temperature
Standard:
-40°C…60°C
(-40°F…140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F…131°F) -
Process temperature
-200°C…200°C
(-328°F…392°F) -
Process pressure
6 bar abs
-
Wetted parts
316L, AlloyC276,
Raman calibration and verification kits
Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
-
Measuring principle
Raman spectroscopy
-
Temperature
Operating:
0 to 40 °C /32 to 104 °F
Storage:
-15 to 50 °C / 5 to 122 °F -
Relative humidity
Storage:
< 80 % Non-Condensing -
Unit dimensions (width x height x depth)
Kit: 235 x 192 x 85 mm
9.3 x 7.6 x 3.4 inch -
Weight
Kit: 1.5 kg / 3.3 lbs
-
Sampling probe compatibility
Raman Rxn-10 (with bio multi optic)
-
Spectral intensity reference
Calibration Reference Standard
-
Spectral intensity output repeatability (at time of certification)
< ±2 %
-
Long term spectral uncertainty (at any wavelength)
±6.05 %
-
Spectral intensity calibration range
CRS-785: 790.7 to 1074.5 nm
-
Measuring principle
Raman spectroscopy
HAW569 Surge arresters
Surge arresters for field mounting
-
Measuring principle
Surge arrester
-
Function
Surge arrester for field installation
Easy and space-saving mounting directly at the field transmitter
Combined protection of sensor cables and supply lines in one device (especially for 4-wire transmitters)
Flexible integration into the measuring chains of the process industry due to approvals according to ATEX & IEC, SIL2 conformity
Compatibility with the established fieldbusses (HART, FF, PA)
Uninterruptible operation of the plant due to an automatic resetting after the discharge process -
Certification
ATEX/IEC Ex ia for lead through version
ATEX/IEC Ex d for screw in version -
Dimensions (wxhxd)
HAW569-xA2B: (lead through version)
Diameter AF/SW27, internal and external thread M20x1.5, length 77 mm (3.03″)
HAW569-CB2C: (screw in version)
Diameter AF/SW27, external thread M20, length 83 mm (3.27″) -
Operating Voltage
24V/120V/230V
-
Measuring principle
Surge arrester
-
Measuring principle
Surge arrester for field mounting
-
Function
Surge arresters are applied to protect electronic components of a plant against overvoltage! Due to this, investment intensive measuring instruments are protected and the plant availability is increased.
-
Application
Surge protection for power supply or signal / communication cables
-
SIL
2
-
Certificates
ATEX
IECEx
CSA
Field of application
The HAW569 surge arrester is used to protect electronic components in field devices from being destroyed. It ensures that overvoltage surges which occur in signal cables (e.g. 4 to 20 mA), in communication lines of Field buses (HART, PA, FF) and in power lines are safely passed into the ground. The functionality of the electronic component to be protected is not affected as, using the impedance-free connection of the protection unit, interference voltage drops cannot be introduced.
HAW569 units are primarily used in process automation and in measuring and communication technology within the chemicals, pharmaceuticals, water and wastewater sectors as well as in the food industry.
Benefits