Turn-key process Raman analyzer for quantitative chemical composition measurements
Rugged, reliable Raman analyzer ensuring 24/7 process and quality monitoring
From smart level monitoring to supply chain management
Very compact flush-mounted probe for liquid and pasty media
Cost effective point level switch for water-based liquids
Robust point level switch with rope extension for fine-grained bulk solids also for hazardous areas
Robust point level switch with extension tube for fine-grained bulk solids also for hazardous areas
Robust point level switch for fine-grained bulk solids also for hazardous areas
Coated point level switch for liquids for FailSafe overfill protection
Point level switch for liquids for FailSafe overfill protection
Point level switch for liquids for FailSafe overfill protection
Point level switch with extension tube for liquids in high-temperature applications
Point level switch for liquids in high-temperature applications
A level switch for hot and pumpable liquids
Proven in the field, easy to use and perfectly suitable for hygienic applications.
A level switch for aggressive and pumpable liquids
Point level switch for liquids with highly corrosion-resistant coating
Point level switch with extension tube for liquids in all industries
Point level switch for liquids in compact hygienic design for the food industry
Point level switch for liquids in compact design with stainless steel housing
Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 20m
Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m
Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m
Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 5m
Cost effective all-round instrument for level applications in liquids and bulk solids
Highest performance for demanding applications
Highest performance in every application
More simplicity with the specialist for hygienic applications
More simplicity for your application
The standard sensor for highest demands in bulk solids level measurement
For level measurement in aggressive liquids or applications with hygiene requirements
Level measurement of liquids and solids in all industries
Level measurement in liquids for water & wastewater and utilities in all industries

Raman Rxn5 process analyzer

Turn-key process Raman analyzer for quantitative chemical composition measurements

  • Measuring principle

    Raman spectroscopy

  • Spectral coverage

    150-3425 cm-1 (532 nm)

  • Spectral resolution

    5 cm-1 (532 nm)

  • Channels

    Up to four channels

  • Temperature

    Operating:
    -20 to 50 °C / -4 to 122 °F
    Recommended storage:
    -30 to 60 °C / -22 to 140 °F

  • Relative humidity

    0 to 90 %, non-condensing

  • Input voltage

    90-264 VAC, 47-63 Hz standard

  • Power consumption (W)

    <300 (max)
    <300 (typical start-up)
    <200 (typical running)

  • Warm up time (minutes)

    120

  • Unit dimensions (width x height x depth)

    457 x 834 x 254 mm
    18.00 x 32.84 x 10.00 inch

  • Weight

    61.2 kg / 135 lbs

  • Sampling probe compatibility

    Raman Rxn-30

  • Automation interface

    Modbus (TCP/IP or RS485)

  • Installation options

    IP 56 wall-mounted, sealed/purged enclosure

  • Hazardous area certifications

    ATEX, CSA, IECEx

Field of application
The Raman Rxn5 process analyzer is an industry-leading, turn-key, laser-based analyzer powered by Kaiser Raman technology. It provides quantitative chemical composition measurements using Raman spectroscopy. The design of the Raman Rxn5 incorporates customer requirements for serviceability and hazard-area certification, provides a compact footprint, and minimizes utilities consumption. The high optical efficiency of the analyzer makes it ideal for typical gas-phase sample measurements.

Process measurement points:Steam methane reformersGasifiers (coal, petcoke, waste, biomass)Shift convertersHydrotreatersHydrocrackersCO2 removalFinished product synthesis loopsTypical industries:Hydrogen production/purity, HyCO, Hydrogen recycle, Methanol productionAmmonia productionGas turbine fuel feedSynthetic natural gal/IGCC power plantsLNG baseload customer transfer, LNG rundown to storage tanks, LNG mixed refrigerant optimization

Benefits
Non-destructive analysis of gases, including homonuclear diatomics (H2, N2, O2)Compact, smaller than most wall-mount gas chromatographs (GCs)Can replace up to four traditional analyzers with a single base unit and four probesRugged with minimal utility requirements, no sample transport, and no consumables (columns, valves, gases, pumps)Minimal analyzer technician time with maximum technician safety (no toxic gases are transported to the analyzer)Measures four streams simultaneously for faster multi-channel results-20 to +50 °C operating environment

Raman Rxn4 analyzer

Rugged, reliable Raman analyzer ensuring 24/7 process and quality monitoring

  • Measuring principle

    Raman spectroscopy

  • Spectral coverage

    Base Model and Enclosure configuration:
    150-4350 cm-1 (532 nm)
    150-3425 cm-1 (785 nm)
    200-2400 cm-1 (1000 nm)
    Hybrid: 175-1890 cm-1 (785 nm)

  • Spectral resolution

    Base model and Enclosure configuration (average):
    5 cm-1 (532 nm)
    4 cm-1 (785 nm)
    5 cm-1 (1000 nm)
    Hybrid:
    4 cm-1 (785 nm) average

  • Channels

    Base model and Enclosure configuration:
    Up to four channels
    Hybrid:
    Up to two channels

  • Temperature

    Base model:
    Operating:
    5 to 35 °C / 41 to 95 °F (532 nm, 785 nm)
    5 to 30 °C / 41 to 86 °F (1000 nm)
    Storage:
    -15 to 50 °C / 5 to 122 °F
    Hybrid:
    Operating: 5 to 35 °C / 41 to 95 °F
    Storage: -15 to 50 °C / 5 to 122 °F
    Enclosure configuration:
    Operating: (all wavelengths)
    5 to 50 °C / 41 to 122 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    20 to 80 %, non-condensing

  • Input voltage

    Base model and Hybrid:
    100-240 V, 50-60 Hz, ±10%
    Enclosure configuration:
    120 V ±10%, 60 Hz -OR-
    230 V ±10%, 50/60 Hz

  • Power consumption (W)

    Base model and Hybrid:
    400 (max)
    250 (typical start-up)
    120 (typical running)
    Enclosure configuration:
    1560 (max)
    1560 (typical start-up)
    750 (typical running)

  • Warm up time (minutes)

    Base model and Hybrid:
    120
    Enclosure configuration:
    240

  • Unit dimensions (width x height x depth)

    Base model and Hybrid:
    483 x 267 x 556 mm
    19.02 x 10.52 x 21.89 inch
    Enclosure configuration: (with optional trolley)
    1175 x 1480 x 826 mm
    46.26 x 58.27 x 32.52 inch

  • Weight

    Base model:
    28.5 kg / 63 lbs
    Enclosure configuration:
    185.5 kg / 409 lbs (with optional trolley)

  • Sampling probe compatibility

    Base model and enclosure configuration:
    Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46
    Hybrid:
    Channel 1 – Raman Rxn-20 (with accessory optics)
    Channel 2 – Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46

  • Automation interface

    OPC
    Modbus
    HTTPS
    (contact us for other options)

  • Installation options

    Base model and Hybrid:
    19-inch rack package
    Enclosure configuration:
    NEMA 4X enclosure; wall-mountable, moblile trolley, or fixed stand

  • Hazardous area certifications

    Base model and Hybrid:
    ATEX, CSA, IECEx
    Enclosure configuration:
    Call support for options

  • Measuring principle

    Raman spectroscopy

  • Spectral coverage

    Base Model and Enclosure configuration:
    150-4350 cm-1 (532 nm)
    150-3425 cm-1 (785 nm)
    200-2400 cm-1 (1000 nm)
    Hybrid: 175-1890 cm-1 (785 nm)

  • Spectral resolution

    Base model and Enclosure configuration (average):
    5 cm-1 (532 nm)
    4 cm-1 (785 nm)
    5 cm-1 (1000 nm)
    Hybrid:
    4 cm-1 (785 nm) average

  • Channels

    Base model and Enclosure configuration:
    Up to four channels
    Hybrid:
    Up to two channels

  • Temperature

    Base model:
    Operating:
    5 to 35 °C / 41 to 95 °F (532 nm, 785 nm)
    5 to 30 °C / 41 to 86 °F (1000 nm)
    Storage:
    -15 to 50 °C / 5 to 122 °F
    Hybrid:
    Operating: 5 to 35 °C / 41 to 95 °F
    Storage: -15 to 50 °C / 5 to 122 °F
    Enclosure configuration:
    Operating: (all wavelengths)
    5 to 50 °C / 41 to 122 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    20 to 80 %, non-condensing

  • Input voltage

    Base model and Hybrid:
    100-240 V, 50-60 Hz, ±10%
    Enclosure configuration:
    120 V ±10%, 60 Hz -OR-
    230 V ±10%, 50/60 Hz

Micropilot FWR30 – The cloud connected radar level sensor

From smart level monitoring to supply chain management

  • Measuring principle

    Level radar

  • Characteristic / Application

    Applications in all industries
    Mobile and stationary storage tanks

  • Specialities

    Commissioning and operation via digital services like “Netilion Value” or “SupplyCare Hosting”

  • Supply / Communication

    Battery powered
    Mobile connectivity with NB-IoT, LTE-M or 2G (fallback)

  • Frequency

    80 GHz

  • Accuracy

    ±10 mm (0.39 in)

  • Process temperature

    -20°C…+60°C (-4°F…+140°F)

  • Main wetted parts

    Housing: plastic PBT/ PC

  • Process connection

    None

  • Max. measurement distance

    15 m (49 ft)

  • Communication

    Wireless
    Mobile connectivity with NB-IoT, LTE-M or 2G (fallback)

  • Options

    Mounting bracket IBC/ pipe
    Mounting bracket wall/ ceiling

  • Application limits

    DK <1.9
    Metallized plastic tanks

  • Measuring principle

    Level radar solid

  • Characteristic / Application

    Applications in all industries
    Mobile and stationary plastic and metal tanks (IBC tanks, storage silos)
    Reliable non-contact level measurement of solids in metal- and plastic containers

  • Specialities

    Commissioning and operation via digital services like “Netilion Value”, “Netilion Inventory” or “SupplyCare Hosting”

  • Supply / Communication

    Battery powered
    Mobile connectivity with NB-IoT, LTE-M or
    2G (fallback)

  • Frequency

    80 GHz

  • Accuracy

    ±10 mm (0.39 in)

  • Process temperature

    -20°C…+60°C (-4°F…+140°F)

  • Main wetted parts

    Housing: plastic PBT/ PC

  • Process connection

    Threads:
    G 1 1/2″, NPT 1 1/2″

  • Max. measurement distance

    15 m (49 ft)

  • Communication

    Wireless
    Mobile connectivity with NB-IoT, LTE-M or
    2G (fallback)

  • Options

    Mounting bracket IBC/ pipe
    Mounting bracket wall/ ceiling

Conductive Point level detection Liquipoint FTW33

Very compact flush-mounted probe for liquid and pasty media

  • Measuring principle

    Conductive

  • Characteristic / Application

    Compact point level switch for using in pipes and in storage, mixing and process vessels with or without an agitator, for water based or oil based media, with active build up compensation,flush mounting

  • Specialities

    CIP and SIP suitable
    Conductive foam is detectable or can be switched off

  • Supply / Communication

    10…30 V DC

  • Ambient temperature

    -40 … 70°C
    (-40 … 158°F)

  • Process temperature

    Standard:
    -20 … 100°C
    Cleaning:
    -20 … 150°C for 1h
    ( -4 … 302°F for 1h)

  • Process pressure / max. overpressure limit

    Vacuum … 25 bar
    (Vacuum … 362,5 psi)

  • Main wetted parts

    Sensor: 316L
    Sensor isolation: PEEK

  • Process connection

    Thread G1, G1/2, G3/4, M24

  • Process connection hygienic

    Clamp ISO 2852 1 to 1 1/2″, 2″,
    DIN11851 Pipe union

  • Communication

    DC PNP

Capacitance Point level detection Liquipoint FTW23

Cost effective point level switch for water-based liquids

  • Measuring principle

    Capacitive Liquid

  • Characteristic / Application

    Compact point level switch for using in water based liquids

  • Specialities

    CIP and SIP suitable

  • Supply / Communication

    10…30 V DC

  • Ambient temperature

    -20…70°C
    -4… 158°F

  • Process temperature

    Standard:
    -20 … 100°C
    Cleaning:
    -20 … 135°C for 1h
    -4 … 275F for 1h

  • Process pressure / max. overpressure limit

    Vacuum … 16 bar
    Vacuum ….232 psi

  • Main wetted parts

    Sensor: 316L
    Sensor isolation: PEEK

  • Process connection

    Thread G1, G1/2, G3/4, M24

  • Communication

    DC PNP
    IO- Link

  • Certificates / Approvals

    CSA C/US

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG

  • Options

    Weld-in adapter,
    Process adapter for hygienic process connections

  • Application limits

    Conductive foam is recognizes as a liquid

Field of application
The Liquipoint FTW23 is developed and built for the food industry and meets all international hygiene requirements. The device also fits perfectly for industrial applications in all industries. It is intended for use in applications in liquid media without build-up. The IO-Link capability allows easy parameter setting.

For use in storage tanks, mixing vessels and pipes. For water-based liquids; Ex works for media with dielectric constant > 20, with adjustment via IO-Link for media with dielectric constant > 1.5 discernible.
Process connections: Threads
Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 135°C (275°F) for 1 hour
Pressure: -1 to 16bar abs (-14.5 to 232psi)
Hygienic certificates

Benefits
Easy installation thanks to compact design, even in tight conditions or where access is restricted IO-Link reduces costs and complexity due to easy configuration of the devices via engineering toolsCIP and SIP cleanability ensured – up to protection class IP 69Individual adjustment to each medium not necessaryLED display for on-site function check

Vibronic Point level detection Soliphant FTM52

Robust point level switch with rope extension for fine-grained bulk solids also for hazardous areas

  • Measuring principle

    Vibration Solids

  • Characteristic / Application

    Point level switch for fine grained solids and powder
    Grain size: <= 10 mm (<= 0.39 in)
    Fork sensor
    No calibration required
    Not affected by build-up or external vibration
    Robust
    Switch value visible from outside
    Rope extension

  • Specialities

    Build-up and corrosion detection
    Remote version
    3 temperature versions available
    SIL 2

  • Supply / Communication

    10-55V DC PNP 3-wire
    19-253V AC 2-wire
    19…253V AC / 19…55V DC 2 relay contact
    8/16mA
    NAMUR
    PFM

  • Ambient temperature

    -50°C … 70°C
    (-60°F … 160°F)

  • Process temperature

    -40°C …80 °C
    (-40°F … 170°F)

  • Process pressure / max. overpressure limit

    Vacuum … 2 bar
    (Vacuum … 30 psi)
    max. 6 bar / 80 psi for EExd/EExde

  • Min. density of medium

    Standard fork: 10 g/l
    Short fork: 50 g/l

  • Main wetted parts

    Sensor selectable:316L 3,2um
    316L 0,8um
    316L PTFE coated (to avoid build-up)
    Rope: PUR, Silicon

  • Max. tensile strength

    3000 N

  • Process connection

    Thread
    R 1 1/2″
    1 1/4″ NPT
    1 1/2″ NPT
    EN Flange DN50…DN100
    ASME Flange 2″…4″
    JIS Flange 50A…100A

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Sensor length

    750….20000mm
    (30…800″)

  • Communication

    DC PNP 2-wire
    AC Thyristor
    DPDT relay
    8/16mA
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN, INMETRO, NEPSI, EAC

  • Safety approvals

    SIL

  • Options

    Glass cover
    Temperature spacerEN10204-3.1

  • Components

    PFM: FTL325P, FTL375P
    NAMUR: FTL325N, FTL375N

Field of application
Soliphant FTM52 is a robust point level switch for use in silos containing fine-grained or powdery solids even with a low bulk density. Suitable for a wide range of applications with international certificates for use in dust or gas hazardous areas. Available with polished fork and stainless steel housing with Tri-Clamp or with aluminum housing and coated fork. Maintenance-free device for use in typical applications like: cereals, flour, cocoa, sugar, animal feed, dye powder, chalk.

Point level switch for fine grained solids and powder.
Process connections: Threads, flanges and hygienic connection (Tri-Clamp)
Temperature: -40 to +80°C (-40 to +170°F)
Pressure: -1 to +2bar (-14.5 to +30psi)
Sensor length: 750mm to 20,000mm
Sensor material: 316L (3,2µm, 0,8µm, PTFE coated)
International explosion protection certificates

Benefits
SIL2 in accordance with IEC 61508No mechanically moved parts, free of maintenanceMeasurement not affected by build-up or external vibrationVarious electronic inserts: e.g. NAMUR, relay, thyristor and PFM-signal outputs for optimum alignment with the plant control systemBuild-up and abrasion display selectable, density setting and switching delay selectableChoice of coated or polished sensorBuild-up and corrosion detection

Vibronic Point level detection Soliphant FTM51

Robust point level switch with extension tube for fine-grained bulk solids also for hazardous areas

  • Measuring principle

    Vibration Solids

  • Characteristic / Application

    Point level switch for fine grained solids and powder
    Grain size: <= 10 mm (<= 0.39 in)
    Fork sensor
    No calibration required
    Not affected by build-up or external vibration
    Robust
    Switch value visible from outside
    Tube extension

  • Specialities

    Build-up and corrosion detection
    Remote version
    3 temperature versions available
    SIL 2

  • Supply / Communication

    DC PNP 3-wire
    AC 2-wire
    19…253V AC / 19V…55V DC 2 relay contact
    8/16mA
    NAMUR
    PFM

  • Ambient temperature

    -50°C … 70°C
    (-60°F … 160 °F)

  • Process temperature

    -50°C … 280°C
    (-60 °F … 540°F)

  • Process pressure / max. overpressure limit

    Vacuum … 25 bar
    (Vacuum … 360 psi)

  • Min. density of medium

    Standard fork: 10 g/l
    Short fork: 50 g/l

  • Main wetted parts

    selectable:
    316L 3,2 µm
    316L 0,8 µm
    316L PTFE coated (to avoid build-up)
    316L ETFE coated (to avoid corrosion)

  • Process connection

    Thread
    R 1 1/2″
    1 1/4″ NPT
    1 1/2″ NPT
    EN Flange DN50…DN100
    ASME Flange 2″…4″
    JIS Flange 50A…100A

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Sensor length

    300 … 4000mm
    (12 … 155″)
    (6000mm / 230″ on request)

  • Communication

    DC PNP 2-wire
    AC Thyristor
    DPDT relay
    8/16mA
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN, INMETRO, NEPSI, EAC

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1

  • Options

    Glass cover
    Temperature spacer
    EN10204-3.1

  • Components

    PFM: FTL325P, FTL375P
    NAMUR: FTL325N, FTL375N

Field of application
Soliphant FTM51 is a robust point level switch for use in silos containing fine-grained or powdery solids even with a low bulk density. Suitable for a wide range of applications with international certificates for use in dust or gas hazardous areas. Available with polished fork and stainless steel housing with Tri-Clamp or with aluminum housing and coated fork. Maintenance-free device for use in typical applications like: cereals, flour, cocoa, sugar, animal feed, dye powder, chalk.

Point level switch for fine grained solids and powder.

Process connections: Threads, flanges and hygienic connection (Tri-Clamp)
Temperature: -50 to +280°C (-60 to +540°F)
Pressure: -1 to +25bar (-14.5 to +360psi)
Sensor length: 300mm to 4,000mm
Sensor material: 316L (3,2µm, 0,8 µm, PTFE coated, ETFE coated)
International explosion protection certificates

Benefits
SIL2 in accordance with IEC 61508No mechanically moved parts, free of maintenanceMeasurement not affected by build-up or external vibrationVarious electronic inserts: e.g. NAMUR, relay, thyristor and PFM-signal outputs for optimum alignment with the plant control systemBuild-up and abrasion display selectable, density setting and switching delay selectableChoice of coated or polished sensorBuild-up and corrosion detection

Vibronic Point level detection Soliphant FTM50

Robust point level switch for fine-grained bulk solids also for hazardous areas

  • Measuring principle

    Vibration Solids

  • Characteristic / Application

    Compact point level switch for fine grained solids and powder
    Grain size <= 10 mm (<= 0.39 in)
    Fork sensor
    No calibration required
    Not affected by build-up or external vibration
    Robust
    Switch value visible from outside

  • Specialities

    Build-up and corrosion detection
    Remote version
    3 temperature versions available
    SIL 2

  • Supply / Communication

    10-55V DC PNP 3-wire
    19-253V AC 2-wire
    19…253V AC / 19V…55V DC 2 relay contact
    8/16mA
    NAMUR
    PFM

  • Ambient temperature

    -50°C … 70°C
    (-60°F … 160 °F)

  • Process temperature

    -50°C … 280°C
    (-60°F … 540°F)

  • Process pressure / max. overpressure limit

    Vacuum … 25 bar
    (Vacuum … 360 psi)

  • Min. density of medium

    Standard fork: 10 g/l
    Short fork: 50 g/l

  • Main wetted parts

    selectable:
    316L 3,2um
    316L 0,8um
    316L PTFE coated (to avoid build-up)
    316L ETFE coated (to avoid corrosion)

  • Process connection

    Thread
    R 1 1/2″
    1 1/4″ NPT
    1 1/2″ NPT
    EN Flange DN50…DN100
    ASME Flange 2″…4″
    JIS Flange 50A…100A

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Sensor length

    Standard: 200mm (8″)
    Short: 145mm (5.7″)

  • Communication

    DC PNP 2-wire
    AC Thyristor
    DPDT relay
    8/16mA
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN, INMETRO, NEPSI, EAC

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1

  • Options

    Glass cover
    Temperature spacer
    EN10204-3.1

  • Components

    PFM: FTL325P, FTL375P
    NAMUR: FTL325N, FTL375N

Field of application
Soliphant FTM50 is a robust point level switch for use in silos containing fine-grained or powdery solids even with a low bulk density. Suitable for a wide range of applications with international certificates for use in dust or gas hazardous areas. Available with polished fork and stainless steel housing with Tri-Clamp or with aluminum housing and coated fork. Maintenance-free device for use in typical applications like: cereals, flour, cocoa, sugar, animal feed, dye powder, chalk.

Point level switch for fine grained solids and powder.

Process connections: Threads, flanges and hygienic connection (Tri-Clamp)
Temperature: -50 to +280°C (-60 to +540°F)
Pressure: -1 to +25bar (-14.5 to +360psi)
Sensor length: 145mm, 200mm
Sensor material: 316L (3,2µm, 0,8µm, PTFE coated, ETFE coated)
International explosion protection certificates

Benefits
SIL2 in accordance with IEC 61508No mechanically moved parts, free of maintenanceMeasurement not affected by build-up or external vibrationVarious electronic inserts: e.g. NAMUR, relay, thyristor and PFM-signal outputs for optimum alignment with the plant control systemBuild-up and abrasion display selectable, density setting and switching delay selectableChoice of coated or polished sensorBuild-up and corrosion detection

Vibronic Point level detection Liquiphant FTL85

Coated point level switch for liquids for FailSafe overfill protection

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Coated point level switch for MIN and MAX safety applications up to SIL3,
    Dual Sealing/ Second line of defense,
    Modular housing concept

  • Specialities

    Outstanding features:
    – permanent LIVE signal monitors function safety
    – failsafe design and
    – high availability of the measuring values

  • Supply / Communication

    2-wire 4…20 mA

  • Ambient temperature

    -50°C…+70°C
    (-58°F…+160°F)

  • Process temperature

    –50°C…+150°C
    (–58°F…+300°F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (580 psi)

  • Min. density of medium

    Density from 0.4 g/cm3
    (0.4 SGU)

  • Main wetted parts

    With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials

  • Process connection

    Flange:
    DN25…DN100,
    ASME 1″…4″,
    JIS 10K…20K

  • Sensor length

    Extension pipe up to 3 m (9.8 ft)

  • Communication

    2-wire 4…20 mA

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC

  • Safety approvals

    Overfill protection WHG
    Leakage Detection
    SIL3

  • Options

    AlloyC Material
    PWIS free
    Pressure tight feed through
    Weather protection

  • Components

    Nivotester FTL825, Transmitter

Field of application
Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

Point level switch for liquids up to SIL3.Process connections: Threads and flangesTemperature: -50 to +150°C (-76 to +300°F)Pressure: -1 to +40bar (-14.5 to +580psi)Sensor length: Extension pipe up to 3m (9.8ft)Sensor material: Enamel, ECTFE and various PFA materialsInternational explosion protection certificates, overfill protection WHG, SIL

Benefits
Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button Permanent self-monitoring/internal redundancy4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLCNo adjustment: quick, low-cost startupNo mechanically moving parts: no maintenance, no wear, long operating lifeMonitoring of fork for damage, corrosion, buildup and mechanical blocking

Vibronic Point level detection Liquiphant FTL81

Point level switch for liquids for FailSafe overfill protection

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Reliable point level switch with extension pipe for MIN and MAX safety applications up to SIL3.
    Dual Sealing / Second line of defense
    Modular housing concept

  • Specialities

    Outstanding features:
    – permanent LIVE signal
    monitors function safety
    – failsafe design and
    – high availability of the measuring values

  • Supply / Communication

    2-wire 4…20 mA

  • Ambient temperature

    -60°C…+70°C
    (-76°F…+160°F)

  • Process temperature

    -60°C…+280°C
    (-76°F…+540°F)

  • Process pressure / max. overpressure limit

    Vacuum…100 bar
    (1450 psi)

  • Min. density of medium

    Density from 0.4 g/cm3
    (0.4 SGU)

  • Main wetted parts

    316L
    Alloy C

  • Process connection

    Flange:
    DN25…DN100,
    ASME 1″…4″,
    JIS 10K…20K
    Thread:
    G3/4, G1, R3/4,
    R1, MNPT3/4, MNPT1

  • Sensor length

    Extension pipe up to 3 m (9.8 ft)

  • Communication

    2-wire 4…20 mA

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC

  • Safety approvals

    Overfill protection WHG
    Leakage Detection
    SIL3

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    PWIS free
    Pressure tight feed through
    Weather protection

  • Components

    Nivotester FTL825, Transmitter

Field of application
Liquiphant FTL81 is a point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

Point level switch for liquids up to SIL3.Process connections: Threads and flangesTemperature: -60 to +280°C (-76 to +540°F)Pressure: -1 to +100bar (-14.5 to +1,450psi)Sensor length: Extension pipe up to 3m (9.8ft)Sensor material: 316L, Alloy CInternational explosion protection certificates, overfill protection WHG, SIL, marine approvals

Benefits
Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a buttonPermanent self-monitoring/internal redundancy4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLCNo adjustment: quick, low-cost startupNo mechanically moving parts: no maintenance, no wear, long operating lifeMonitoring of fork for damage, corrosion, build-up and mechanical blocking

Vibronic Point level detection Liquiphant FTL80

Point level switch for liquids for FailSafe overfill protection

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Compact point level switch for MIN and MAX safety applications up to SIL3,
    Dual Sealing/ Second line of defense
    Modular housing concept

  • Specialities

    Outstanding features:
    – permanent LIVE signal monitors function safety
    – failsafe design and
    – high availability of the measuring values

  • Supply / Communication

    2-wire 4…20 mA

  • Ambient temperature

    -60°C…+70°C
    (-76°F…+160°F)

  • Process temperature

    -60°C…+280°C
    (-76°F…+540°F)

  • Process pressure / max. overpressure limit

    Vacuum…100 bar
    (1450 psi)

  • Min. density of medium

    Density from 0.4 g/cm3
    (0.4 SGU)

  • Main wetted parts

    316L,
    Alloy C

  • Process connection

    Flange:
    DN25…DN100
    ASME 1″…4″
    JIS 10K…20K
    Thread:
    G3/4, G1, R3/4,
    R1, MNPT3/4, MNPT1

  • Sensor length

    Compact

  • Communication

    2-wire 4…20 mA

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC

  • Safety approvals

    Overfill protection WHG
    Leakage
    SIL3

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    PWIS free
    Pressure tight feed through
    Weather protection

  • Components

    Nivotester FTL825, Transmitter

Field of application
Liquiphant FTL80 is a point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

Point level switch for liquids up to SIL3.Process connections: Threads and flangesTemperature: -60 to +280°C (-76 to +540°F)Pressure: -1 to +100bar (-14.5 to +1,450psi)Sensor material: 316L, Alloy CInternational explosion protection certificates, overfill protection WHG, SIL, marine approvals

Benefits
Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button Permanent self-monitoring/internal redundancy4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLCNo adjustment: quick, low-cost startupNo mechanically moving parts: no maintenance, no wear, long operating lifeMonitoring of fork for damage, corrosion, build-up and mechanical blocking

Vibronic Point level switch Liquiphant FTL71

Point level switch with extension tube for liquids in high-temperature applications

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Modular housing concept
    High process temperatures up to 280°C
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g. Ex,WHG)
    compact, e.g. pipes
    Dual Sealing / Second line of defense

  • Specialities

    Foam detection
    Detect a density change
    second line of defense

  • Supply / Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC bzw 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °F…+158 °F)

  • Process temperature

    -60 °C…+280 °C
    (-76 °F…+540 °F)
    (300°C / 572°F, 50h cumulated)

  • Process pressure / max. overpressure limit

    Vacuum…100 bar
    (Vacuum…1450 bar)

  • Min. density of medium

    0.5g/cm³ (0.4g/cm³ optional)

  • Main wetted parts

    316L / Alloy
    PFA and Enamel on request

  • Process connection

    Thread:
    G3/4A, G1A, R3/4″, R1, NPT3/4, NPT1
    Flange:
    DIN DN25…DN100,
    ASME 1″…4″,
    JIS 25A…100A

  • Sensor length

    Length 130mm (5.12″) (Liquiphant II)
    148mm…3000mm / 6000mm optional
    (5.83″…118″ / 236″ optional)

  • Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC bzw 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS

  • Options

    Heavy duty stainless steel housing mainly for the oil and gas industry

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

Field of application
Liquiphant FTL71 is a point level switch with extension tube for use in hazardous areas with all international certificates. FTL71 is especially designed for applications with high process temperatures up to 280°C and can be used up to SIL2, in homogeneous redundancy up to SIL3. An integrated second line of defense offers the highest degree of safety. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

Point level switch for all liquids.Process connections: Threads and flangesTemperature: -60 to +280°C (-76 to +540°F)Pressure: -1 to +100bar (-14.5 to +1,450psi)Sensor material: 316L, Alloy (PFA and Enamel on request)International explosion protection certificates, overfill protection WHG, SIL, marine approvals

Benefits
Use in safety systems requiring functional safety to SIL2 in accordance with IEC 61508/IEC 61511-1 With welded gas-tight feed-through maximum safety in the event of damaged sensor Wide variety of electronics, e.g. NAMUR, relay, thyristor, PFM signal output: the right connection for every process control systemLarge number of process connections to choose from: universal usageNo calibration: quick, low-cost start-upNo mechanically moving parts: no maintenance, no wear, long operating life. Monitoring of fork for damage: guaranteed functionFDA approved materials (PFA Edlon)

Vibronic Point level detection Liquiphant FTL70

Point level switch for liquids in high-temperature applications

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Modular housing concept
    High process temperatures up to 280°C
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g. Ex,WHG)
    compact, e.g. pipes
    Dual Sealing / Second line of defense

  • Specialities

    Foamdetection
    Detect a densitychange
    second line of defense

  • Supply / Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC bzw 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °F…+158 °F)

  • Process temperature

    -60 °C…+280 °C
    (-76 °F…+540 °F,
    (300°C / 572 °F 50h, cumulated

  • Process pressure / max. overpressure limit

    Vacuum…100 bar
    (Vacuum…1450 psi)

  • Main wetted parts

    316L / Alloy
    PFA and Enamel on request

  • Process connection

    Thread:
    G3/4A, G1A, R3/4″, R1, NPT3/4, NPT1
    Flange:
    DIN DN25…DN100,
    ASME 1″…4″,
    JIS 25A…100A

  • Sensor length

    65mm (2.56″)

  • Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC bzw 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS

  • Options

    Heavy duty stainless steel housing mainly for the oil and gas industry

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

Field of application
Liquiphant FT70 is a point level switch for use in hazardous areas with all international certificates. FTL70 is especially designed for applications with high process temperatures up to 280°C and can be used for Safety Instrumented Systems up to SIL2, in homogeneous redundancy up to SIL3. An integrated second line of defense offers the highest degree of safety. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

Point level switch for all liquids.Process connections: Threads and flangesTemperature: -60 to +280°C (-76 to +540°F)Pressure: -1 to +100bar (-14.5 to +1,450psi)Sensor material: 316L, Alloy (PFA and Enamel on request)International explosion protection certificates, overfill protection WHG, marine approvals, SIL

Benefits
Use in safety systems requiring functional safety to SIL2 in accordance with IEC 61508/IEC 61511-1 With welded gas tight feedthrough maximum safety in the event of damaged sensor Wide variety of electronics, e.g. NAMUR, relay, thyristor, PFM signal output: the right connection for every process control systemLarge number of process connections to choose from: universal usageNo calibration: quick, low-cost start-upNo mechanically moving parts: no maintenance, no wear, long operating life.Monitoring of fork for damage: guaranteed functionFDA approved materials (PFA Edlon)

Liquiphant FTL64 – reliable detection at high temperatures

A level switch for hot and pumpable liquids

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Compact vibronic device for high pressure and high temperature applications,
    Optional extension tube up to 6 m (19.7 ft),
    Modular housing concept,
    Wide range of certificates

  • Specialities

    Heartbeat Technology,
    Bluetooth® Operation and maintenance SmartBlue App,
    LED Module,
    RFID TAG for easy identification,
    Second line of defense,
    Temperature spacer for high process temperature,
    Plug and play functionalities

  • Supply / Communication

    19…253V AC / 2-wire,
    10…55V / DC-PNP 3-wire,
    9…20V DC with relay DPDT,
    19…253V AC or 19…55V DC with relay DPDT,
    2-wire NAMUR,
    2-wire PFM,
    4-20mA HART

  • Ambient temperature

    -60 °C…+70 °C
    (-76 °F…+158 °F)

  • Process temperature

    -60 °C…+280 °C
    (-76 °F…+536 °F)

  • Process pressure / max. overpressure limit

    Vacuum…100 bar
    Vacuum…1450 psi

  • Min. density of medium

    0.5 g/cm³
    (0.4 g/cm³ optional)

  • Main wetted parts

    316L
    Alloy

  • Process connection

    Threads:
    3/4″, 1″
    Flanges:
    DN25…DN100
    ASME 1″…4″
    JIS 50A

  • Sensor length

    up to 6 m (19.7 ft)

  • Communication

    2-wire direct load
    HART
    DC-PNP 3-wire
    Relays
    NAMUR
    PFM
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, IEC Ex, NEPSI, EAC Ex, KC, JPN Ex, INMETRO, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL2/ SIL 3 according to IEC 61508

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3 Process Piping
    AD2000
    CRN

  • Marine approval

    ABS/ LR/ BV/ DNV

  • Options

    Ambient temperature down to -60 °C (-76 °F),
    Heavy duty stainless steel housing,
    Coating PFA (conductive)

  • Components

    FTL325P Interface PFM
    FTL325N Interface NAMUR

Field of application
Liquiphant FTL64 has a strong focus on high temperature applications and simplicity with easy proof testing, reliability and safety (SIL) with compliance to IEC 61508, API 2350 and WHG. The vibronic device is determined for a safe and active measuring technology in applications with high temperatures and want a reliable and proven point level detection for tank overfill protection and pump dry run protection. The FTL64 is easy to use, has a digital connection and gives a real-time data at hand.

Point level switch with extension tube for pumpable liquidsProcess temperature: -60 °C to +280°C (PFA coated: up to 230°C) Process pressure: -1 to +100bar (PFA coated: up to 40bar) Ambient temperature: -60 to +70°C Viscosity up to 10,000mm2/s (cSt) Optional PFA coating for aggressive media Process connections: threads, flanges and hygienic process connection (Tri-Clamp)International explosion protection certificates, overfill protection WHG, SIL, marine approvals

Benefits
Universal measuring principle for limit detection – proven vibronic technology Developed according IEC 61508 for highest safety – SIL2/3 applications (3rd party approved)Periodic proof testing is quickly and simple organized with guided wizards via the SmartBlue-App or via a test button or magnetic pin from outside. Via digital communication you can initiate the device for a fast and easy testing of the safety loop.Heartbeat Technology allows safe, continuous diagnostics and a simple verification, without process interruptionCentralized asset management with easy online access to all device information thanks to digital communication Second line of defense to protect the environment

Liquiphant FTL63 – hygienic point level switch for liquids

Proven in the field, easy to use and perfectly suitable for hygienic applications.

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Premium device for point level detection
    in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
    Modular housing concept.
    Wide range of certificates.

  • Specialities

    Plug and play functionalities,
    Heartbeat Technology,
    LED Module,
    Bluetooth® Operation and maintenance,
    Surface finish: mechanical or electro-polished,
    Density/Concentration measurement,
    SIL 2/3 according to IEC 61508.

  • Supply / Communication

    19 ..253V AC,
    10…55V DC-PNP,
    9…20V DC with relay DPDT,
    19…253V AC or 19…55V DC with relay DPDT,
    8/16mA HART,
    NAMUR,
    PFM

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…64 bar
    (Vacuum…928 psi)

  • Min. density of medium

    0.5 g/cm³
    (0.4 g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads (for weld-in adapter):
    G3/4A, G1A

  • Process connection hygienic

    Tri-Clamp,
    DIN 11851, DIN11864-1
    Ingold,
    Flush mount,
    DRD,
    SMS1145,
    Varivent (Var )

  • Sensor length

    Compact sensor
    Short tube (Liquiphant II)
    148mm…3000mm (6,00…118″)

  • Communication

    HART
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, IEC Ex, CSA C/US, JPN Ex, KC Ex,
    INMETRO Ex, NEPSI Ex/CCC, UK Ex

  • Safety approvals

    Overfill protection WHG;
    SIL 2/ SIL 3

  • Design approvals

    Inspection certificate 3.1, EN10204,
    CoC ASME BPE,
    Conformity to cGMP,
    EU Food Contact Material (EC) 1935/2004,
    US Food Contact Material FDA CFR 21,
    CN Food Contact Material GB 4806,
    Declaration of Conformity ASME B31.3,
    AD2000,
    CRN approval

  • Hygienic approvals

    3-A,
    EHEDG,
    CoC-ASME BPE

  • Options

    LED module,
    Bluetooth module,
    Graphic touch display,
    Customized settings,
    Weld-in adapter

  • Components

    FTL325P Interface PFM
    FTL325N Interface NAMUR
    FML621 Density controller

  • Measuring principle

    Vibration Density

  • Product Headline

    Hygienic point level switch for liquids.
    Point level detection in process and storage tanks as well as in pipelines in hygienic and aseptic applications.

  • Characteristic / Application

    Premium device for density measurement in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
    Modular housing concept.
    Wide range of certificates.

  • Supply / Communication

    via density controller FML621

Liquiphant FTL62 – the specialist for aggressive media

A level switch for aggressive and pumpable liquids

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Compact vibronic device with highly corrosion-resistant coating for aggressive media,
    Optional extension tube up to 3 m (9.8ft),
    Modular housing concept

  • Specialities

    Heartbeat Technology,
    Bluetooth® Operation and maintenance SmartBlue App,
    LED Module,
    RFID TAG for easy identification,
    Second line of defense
    Temperature spacer for high process temperature,
    Plug and play functionalities

  • Supply / Communication

    19…253V AC / 2-wire,
    10…55V / DC-PNP 3-wire,
    9…20V DC with relay DPDT,
    19…253V AC or 19…55V DC with relay DPDT,
    2-wire NAMUR,
    2-wire PFM,
    4-20mA HART

  • Ambient temperature

    -60 °C…+70 °C
    (-76 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    Vacuum…580 psi

  • Min. density of medium

    0.5 g/cm³
    (0.4 g/cm³ optional)

  • Main wetted parts

    ECTFE,
    PFA (Edlon, RubyRed or conductive)
    316L
    Enamel

  • Process connection

    Flanges:
    DN25…DN100
    ASME 1″…4″
    JIS 50A

  • Sensor length

    Up to 3 m (9.8 ft)

  • Communication

    2-wire direct load
    HART
    DC-PNP 3-wire
    Relays
    NAMUR
    PFM
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, IEC Ex, NEPSI, EAC Ex, KC, JPN Ex, INMETRO, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL2/ SIL 3 according to IEC 61508

  • Design approvals

    EN 10204-3.1
    ASME B31.3 Process Piping
    CRN

  • Marine approval

    ABS/ LR/ BV/ DNV

  • Options

    Ambient temperature down to -60 °C (-76 °F),
    Heavy duty stainless steel housing

  • Components

    FTL325P Interface PFM
    FTL325N Interface NAMUR

  • Measuring principle

    Vibration Density

  • Product Headline

    Coated Liquiphant with Density Computer FML621

  • Characteristic / Application

    Compact vibronic device with highly corrosion-resistant coating for aggressive media,
    Optional extension tube up to 3 m (9.8ft),
    Modular housing concept

  • Ambient temperature

    -60 °C…+70 °C
    (-51 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure

    Vacuum…40 bar
    Vacuum…580 psi

  • Sensor length

    Up to 3 m (9.8ft)

  • Certificates / Approvals

    ATEX, IEC Ex

  • Specialities

    Heartbeat Technology,
    Bluetooth® Operation and maintenance SmartBlue App,
    LED Module,
    RFID TAG for easy identification,
    Second line of defense
    Temperature spacer for high process temperature,
    Plug and play functionalities

Vibronic Point level detection Liquiphant FTL51C

Point level switch for liquids with highly corrosion-resistant coating

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    High protection against aggressive media by using antistatic coating
    Modular housing concept
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g.Ex,WHG)
    pipe extension up to 3m (6m option)

  • Specialities

    Foamdetection
    Detekt a densitychange
    second line of defense

  • Supply / Communication

    PROFIBUS PA
    19…253V AC, 2-wire
    10…55V DC-PNP, 3-wire
    DPDT, 19…253V AC, 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM, 2-wire
    NAMUR with testbutton

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °C…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)
    up to 230 °C / 450°F on request

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Min. density of medium

    0.5g/cm³ (0.4g/cm³ optional)

  • Main wetted parts

    ECTFE
    PFA (Edlon)
    PFA (Rubyred)
    PFA (conductive)
    Enamel

  • Process connection

    Flange:
    DN25…DN100,
    ASME 1″…3″,
    JIS RF10 K 50

  • Process connection hygienic

    FDA conform with PFA (Edlon)

  • Sensor length

    ECTFE, PFA 130mm, 148mm…3000mm
    (ECTFE, PFA 5.12″, 5.83″…118″)
    Enamel 130mm, 148mm…1200mm
    (Enmal 5.12″, 5.83″…47.24″)

  • Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC bzw 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    SIL2/ SIL3

  • Design approvals

    EN 10204-3.1

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Heavy duty stainless steel housing mainly for the oil and gas industry

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

  • Measuring principle

    Vibration Density

  • Characteristic / Application

    Liquiphant M Density
    with Density Computer FML621
    Temperature and pressure measurement
    High protection against aggressive media by using antistatic coating
    Modular housing concept
    Wide range of process connections
    Pipe extension up to 3 m (6 m option)

  • Supply / Communication

    Transmitter power supply (MUS)

  • Ambient temperature

    -50…80°C
    -50…60°C for hazardous applications

  • Process temperature

    0…80 °C (validity of accuracy data)
    -50…0°C / 80…150 °C (with reduced technical data)

  • Process pressure

    0…25 bar
    >25…40 bar (with reduced technical data)

  • Wetted parts

    ECTFE, PFA and Enamel

  • Sensor length

    115…3000 mm
    (depends by the covering)

  • Output

Vibronic Point level detection Liquiphant FTL51

Point level switch with extension tube for liquids in all industries

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Modular housing concept
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g. Ex,WHG)
    pipe extension up to 3m (6m option)

  • Specialities

    Foamdetection
    Detect a densitychange
    second line of defense

  • Supply / Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC or 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…100 bar

  • Min. density of medium

    0.5g/cm³(0.4g/cm³ optional)

  • Main wetted parts

    316L / Alloy

  • Process connection

    Thread:
    G3/4A, G1A, R3/4″, R1, NPT3/4, NPT1
    Flange:
    DN25…DN100,
    ASME 1″…4″,
    JIS 25A…100A

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Sensor length

    Length 130mm (5.12″) (Liquiphant II)
    148mm…6000mm (5.83″…236″)

  • Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC bzw 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    SIL2/ SIL3

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Heavy duty stainless steel housing mainly for the oil and gas industry

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

  • Successor

    Liquiphant FTL51B

  • Measuring principle

    Vibration Density

  • Characteristic / Application

    Liquiphant M Density
    with Density Computer FML621
    Temperature and pressure measurement
    Modular housing concept
    Wide range of process connections
    Pipe extension up to 3 m (6 m option)

  • Supply / Communication

    Transmitter power supply (MUS)

  • Ambient temperature

    -50…70°C
    -50…60°C for hazardous applications

  • Process temperature

    0…80°C (validity of accuracy data)
    -50…0°C / 80…150 °C (with reduced technical data)

  • Process pressure

    0…25 bar
    >25..100 bar (with reduced technical data)

  • Wetted parts

    316L/C4

  • Sensor length

    115…3000 mm
    >3000…6000 mm (Option)

  • Output

    Pulse

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Specialities

    Commissioning with ReadWin2000

Vibronic Point level detection Liquiphant FTL33

Point level switch for liquids in compact hygienic design for the food industry

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Point level switch for liquids
    in the food sector

  • Supply / Communication

    20 … 253V AC/DC, 2-wire
    10 … 30V DC-PNP, 3-wire

  • Ambient temperature

    -40 °C … 70 °C
    (-40 °F … 158 °F)

  • Process temperature

    -40 °C … 150 °C
    (-40 °F … 302 °F)

  • Process pressure / max. overpressure limit

    Vacuum … 40 bar
    (Vacuum … 580 psi)

  • Min. density of medium

    >0,7g/cm³
    (>0,5g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads:
    G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1

  • Process connection hygienic

    Flush mount by use of weld in adapter
    DIN11851
    Tri-Clamp

  • Communication

    AC/DC, DC-PNP, IO-Link

  • Certificates / Approvals

    CSA C/US, EAC

  • Safety approvals

    Overfill protection WHG
    Leakage

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG

  • Options

    Switching delay
    Cleaned from oil+grease,
    Surface finish measurement

Field of application
Liquiphant FTL33 is a point level switch for liquids. The FTL33 is especially designed for food & beverage applications where hygienic requirements are requested. The Liquiphant is used for overfill protection or pump dry-run protection. The IO-Link capability allows easy parameter setting.Compact:- Smallest vibronic sensor in the marketSafe:- Continuous self-monitoring- Reliable switching independent of media propertiesEasy:- No calibration- Plug & play-IO-Link connectivity

Point level switch in compact hygienic design with stainless steel housing for the food industry.Process connections: Threads, hygienic process connections, M24 process adapterTemperature: -40 to +150°C (-40 to +302°F)Pressure: -1 to +40bar (-14.5 to +580psi)Surface roughness: 0.76µm or 1.5µmOverfill protection and leakage detection WHG, hygienic certificates, final inspection report

Benefits
Designed for hygienic applications especially in the food industry – hygienic process connections and approvals available. IO-Link reduces costs and complexity due to easy configuration of the devices via engineering toolsCIP and SIP cleanability ensured – up to protection class IP69k Designed according to highest requirements to quality and environmental sustainability, the self-monitoring Liquiphant offers safe switching also in case of power supply loss Independent of changing media properties an accurate switching point is offered A real plug & play sensor is offered without any need for adjustment even with changing media. Measurement is unaffected by conductivity, build-up, turbulence, flows or air bubbles No calibration is required, no specific know-how or tools (e.g. software) necessary Robust design made of stainless steel (316L) assures highest durability – no mechanically moved parts, free of maintenance

Vibronic Point level detection Liquiphant FTL31

Point level switch for liquids in compact design with stainless steel housing

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Level switch for liquids and is used in tanks, vessels
    and pipes.

  • Supply / Communication

    20 … 253V AC/DC, 2-wire
    10 … 30V DC-PNP 3-wire

  • Ambient temperature

    -40 °C … 70 °C
    (-40 °F … 158 °F)

  • Process temperature

    -40 °C … 150 °C
    (-40 °F … 302 °F)

  • Process pressure / max. overpressure limit

    Vacuum … 40 bar
    (Vacuum … 580 psi)

  • Min. density of medium

    >0,7g/cm³
    (>0,5g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads:
    G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1

  • Communication

    AC/DC, DC-PNP

  • Certificates / Approvals

    CSA C/US, EAC

  • Safety approvals

    Overfill protection WHG
    Leakage

  • Design approvals

    EN 10204-3.1

  • Marine approval

    ABS/ LR/ BV/ DNV

  • Options

    Adjustment switching delay
    Cleaned from oil+grease,
    PWIS free

Field of application
Liquiphant FTL31 is a point level switch for liquids. The FTL31 is designed for industrial applications in all industries, mainly the machinery industry. The Liquiphant is used for overfill protection or pump dry-run protection in cleaning systems. The IO-Link capability allows easy parameter setting.Compact:- Smallest vibronic sensor in the marketSafe:- Continuous self-monitoring-Reliable switching independent of media propertiesEasy:- No calibration – Plug & play- IO-Link connectivity

Point level switch in compact design with stainless steel housing.Process connections: ThreadsTemperature: -40 to +150°C (-40 to +302°F)Pressure: -1 to +40bar (-14.5 to 580psi)Surface roughness: 3.2µmOverfill protection and leakage detection WHG, marine approvals, final inspection report

Benefits
Designed according to highest requirements to quality and environmental sustainability. The self-monitoring Liquiphant offers safe switching also in case of power supply loss. Independent of changing media properties an accurate switching point is offered. IO-Link reduces costs and complexity due to easy configuration of the devices via engineering toolsA real plug & play sensor is offered without any need for adjustment even with changing media. Measurement is unaffected by conductivity, build-up, turbulence, flows or air bubblesNo calibration is required, no specific know-how or tools (e.g. software) necessaryRobust design made of stainless steel (316L) assures highest durabilityA modular design offers different process temperatures and the widest variety of process connections and accessories in the market to fit every applicationNo mechanically moved parts, free of maintenance

Ultrasonic measurement Time-of-Flight Prosonic FMU44

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 20m

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0,7 bar … 2,5 bar abs
    (10 psi … 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN100, ASME 4″, JIS 10K 100
    DN150, ASME 6″, JIS 10K 150
    DN200, ASME 8″, JIS 10K 200
    Mounting bracket

  • Blocking distance

    0.5 m (1.9 ft)

  • Max. measurement distance

    Liquids: 20 m (66 ft),
    Solids: 10 m (33 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Fast filling and discharging rate:
    FMU90 + FDU9x
    Level limit detection:
    FMU90 + FDU9x

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0,7 bar … 2,5 bar abs
    (10 psi … 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN100, ASME 4″, JIS 10K 100
    DN150, ASME 6″, JIS 10K 150
    DN200, ASME 8″, JIS 10K 200
    Mounting bracket

  • Blocking distance

    0.5 m (1.9 ft)

  • Max. measurement distance

    Liquids: 20 m (66 ft),
    Solids: 10 m (33 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

Field of application
The Prosonic FMU44 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

Two-wire or four wire instrument for continuous non-contact level and flow measurement.

Process connection: Flange
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: +0.7 to +2.5bar (+10 to +36psi)
Maximum measuring distance: Liquids 20m (66ft), Solids 10m (33ft)
Blocking distance: Liquids and Solids 0.5m (1.9ft)
International explosion protection certificates

Benefits
Reliable non-contact measurementQuick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectableEnvelope curves on the on-site display for simple diagnosisHermetically sealed and potted sensorChemically resistant sensor out of PVDFCalibration without filling or dischargingIntegrated temperature sensor for automatic correction of the temperature dependent sound velocity

Ultrasonic measurement Time-of-Flight Prosonic FMU42

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 2.5 bar abs
    (10 psi … 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN80, ASME 3″, JIS 10K 80
    DN100,ASME 4″, JIS 10K 100
    Mounting bracket

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Foam / high turbulence possible:
    FMU44/FDU92
    Fast filling and discharging
    rate:
    FMU90 + FDU9x
    Level limit detection
    FMU90 + FDU9x

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 2.5 bar abs
    (10 psi … 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN80, ASME 3″, JIS 10K 80
    DN100,ASME 4″, JIS 10K 100
    Mounting bracket

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

Field of application
The Prosonic FMU42 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

Two-wire or four wire instrument for continuous non-contact level and flow measurement.
Process connection: Flange
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: +0.7 to +2.5bar (+10 to +36psi)
Maximum measuring distance: Liquids 10m (33ft), Solids 5m (16ft)
Blocking distance: Liquids and Solids 0.4m (1.3ft)
International explosion protection certificates

Benefits
Reliable non-contact measurementQuick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectableEnvelope curves on the on-site display for simple diagnosisHermetically sealed and potted sensorChemically resistant sensor out of PVDFCalibration without filling or dischargingIntegrated temperature sensor for automatic correction of the temperature dependent sound velocity

Ultrasonic measurement Time-of-Flight Prosonic FMU41

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 2 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 2″

  • Blocking distance

    0.35 m (1.15 ft)

  • Max. measurement distance

    Liquids: 8 m (26 ft),
    Solids: 3.5 m (11 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    For higher resistance:
    FMU42/FDU9x
    Foam / high turbulence possible:
    FMU42/FDU91
    Fast filling and discharging rate:
    FMU90 + FDU9x
    Level limit detection:
    FMU90 + FDU9x

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 2 mm or +/- 0,2 % of set measuring range 1)

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 2″

  • Blocking distance

    0.35 m (1.15 ft)

  • Max. measurement distance

    Liquids: 8 m (26 ft),
    Solids: 3.5 m (11 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

  • Measuring principle

    Ultrasonic

  • Product headline

    Compact ultrasonic measuring instrument
    Cost effective solution for open channels

  • Max. measurement error

    Low accuracy

  • Measuring range

    Measuring distance 0,4…8m [1.3…26ft]

  • Max. process pressure

    atm.

  • Medium temperature range

    -40°C…80°C
    (-40°F…176°F)

Ultrasonic measurement Time-of-Flight Prosonic FMU40

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 5m

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 2 mm or +/- 0.2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 1 1/2″

  • Blocking distance

    0.25 m (0.8 ft)

  • Max. measurement distance

    Liquids: 5 m (16 ft),
    Solids: 2 m (6.6 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    For higher resistance:
    FMU42/FDU9x
    Foam / high turbulence possible:
    FMU41/FDU91
    Fast filling and discharging rate:
    FMU90 + FDU9x
    Level limit detection:
    FMU90 + FDU9x

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 2 mm or +/- 0.2 % of set measuring range 1)

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 1 1/2″

  • Blocking distance

    0.25 m (0.8 ft)

  • Max. measurement distance

    Liquids: 5 m (16 ft),
    Solids: 2 m (6.6 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

  • Measuring principle

    Ultrasonic Limit

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Ambient temperature

Ultrasonic measurement Time-of-Flight Prosonic FMU30

Cost effective all-round instrument for level applications in liquids and bulk solids

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire

  • Accuracy

    +/- 3 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -20 °C … 60 °C
    (-4 °F … 140 °F)

  • Process temperature

    -20 °C … 60 °C
    (- 4°F … 140 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 44 psi)

  • Main wetted parts

    PP/EPDM

  • Process connection

    G / NPT 1 1/2″
    G / NPT 2″

  • Blocking distance

    1 1/2″: 0.25 m (0.8 ft)
    2″:0.35 m (1.15 ft)

  • Application

    Application

  • Max. measurement distance

    Max. measurement distance

  • Communication

    4…20 mA

  • Certificates / Approvals

    ATEX, CSA C/US, IEC Ex, NEPSI

  • Options

    Accessory Enclosed:
    UNI flange 2″ … 4″

  • Application limits

    Application limits

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire

  • Accuracy

    +/- 3 mm or +/- 0.2 % of set measuring range

  • Ambient temperature

    -20 °C … 60 °C
    (-4 °F … 140 °F)

  • Process temperature

    -20 °C … 60 °C
    (-4 °F … 140 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 44 psi)

  • Main wetted parts

    PP/EPDM

  • Process connection

    G / NPT 1 1/2″
    G / NPT 2″

  • Blocking distance

    Sensor 1 1/2″: 0.25 m
    Sensor 2″: 0.35 m

  • Max. measurement distance

    Sensor 1-1/2″: 2 m (6.6 ft)
    Sensor 2″: 3.5 m (11 ft)

  • Communication

    4…20 mA

  • Certificates / Approvals

    ATEX, CSA C/US, IEC Ex, NEPSI

Micropilot FMR67B – 80 GHz radar sensor

Highest performance for demanding applications

  • Measuring principle

    Level radar solid

  • Characteristic / Application

    Reliable, non-contact level measurement for high silos,
    bunkers or stockpiles, especially with many installations,
    long measuring ranges and heavy buildup

  • Specialities

    Heartbeat Verification + Monitoring, SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning, operation and maintenance with
    SmartBlue App, HistoROM, RFID TAG for easy identification
    Very narrow beam angle, Purge air connection, Alignment device

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA)
    PROFINET with Ethernet-APL
    Bluetooth® wireless technology

  • Frequency

    W-Band (~80 GHz)

  • Antenna

    2″ / 50mm drip-off, PTFE
    3″ / 80mm flush, PTFE
    2.6″ / 65mm horn antenna, 316L

  • Accuracy

    +/- 3 mm (0.12 in)

  • Ambient temperature

    -40 … +85 °C (-40 … +185 °F)

  • Process temperature

    -40 … +450 °C (-40 … +842 °F)

  • Process pressure / max. overpressure limit

    Vacuum…160 bar (2320 psi)

  • Main wetted parts

    Horn antenna: 316L / 1.4404, Al2O3 (ceramic),
    graphite Flush / Drip-off antenna: PTFE

  • Process connection

    Flange:
    Standard or UNI DN80…DN250

  • Max. measurement distance

    125 m (410 ft)

  • Communication

    HART/ PROFIBUS PA
    PROFINET with Ethernet-APL
    Bluetooth® wireless
    technology and app (optional)

  • Certificates / Approvals

    IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex,
    INMETRO Ex, NEPSI Ex, UK Ex

  • Safety approvals

    SIL2, SIL3

  • Design approvals

    Acceptance test certificate 3.1, EN10204;
    NACE MR0175 / ISO 15156;
    EU Food Contact Material (EC) 1935/2004;
    US Food Contact Material FDA CFR 21;
    Declaration of Conformity ASME B31.3;
    CRN approval

  • Marine approval

    ABS, LR, BV, RINA, DNV

  • Options

    Display, Customized settings,
    App ‘SmartBlue’ for commissioning and operation via Bluetooth
    Heartbeat for batch detection; Gas-tight implementation;
    Overvoltage protection; PWIS free

Field of application
Micropilot FMR67B is part of the new generation of 80 GHz radar sensors. It is suitable for continuous non-contact level measurement in demanding solid applications – even with extreme process temperatures. Wizards guide users through commissioning, proof tests and verification of the devices and thus guarantee a simple operation. The narrow beam angle is suitable for measurements in narrow silos. Heartbeat Technology identifies anomalies for increased safety and productivity.

The Micropilot FMR67B is suitable for free space applications up to 125m and offers high beam focusing for vessels with many internal fittings. Process connections: FlangesTemperature: –40 to +450 °C (-40 to +842° F) Pressure: –1 to +160 bar (-14.5 to +2320.6 psi)Maximum measuring range: 125 m (1410 ft)Accuracy: ±3 mm (0.12 in) W-Band: 80 GHzInternational explosion protection certificates, SIL, 5- or 10-point factory calibration certificate

Benefits
Easy handling through intuitive operation and wizards, for commissioning and verificationIncreased productivity thanks to process monitoring, verification, and diagnostics in the running process with Heartbeat Technology Safety by Design: Device development according to IEC 61508 Simple device integration into asset management systems through digital communication Highly reliable measurement thanks to narrow beam angle and intelligent evaluation even in vessels with interfering installations

Micropilot FMR66B – 80 GHz radar sensor

Highest performance in every application

  • Measuring principle

    Level radar solid

  • Characteristic / Application

    For simple applications:
    Reliable, non-contact measurement of levels
    in silos or storage tanks for bulk solids

  • Specialities

    Heartbeat Verification + Monitoring, Bluetooth® Commissioning,
    operation and maintenance with SmartBlue App,
    HistoROM, RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA)
    PROFINET with Ethernet-APL
    Bluetooth® wireless technology

  • Frequency

    W-Band (~80 GHz)

  • Antenna

    1-1/2″ / 40mm encapsulated, PVDF
    2″ / 50mm Drip-off, PTFE

  • Accuracy

    +/- 3 mm (0.12 in)

  • Ambient temperature

    -40 … +85 °C (-40 … +185 °F)

  • Process temperature

    -40 … +130 °C (-40 … +266 °F)

  • Process pressure / max. overpressure limit

    Vacuum…16 bar (232 psi)

  • Main wetted parts

    PVDF or PTFE

  • Process connection

    Thread:
    G1-1/2″, MNPT1-1/2″
    Flange:
    UNI DN80…DN150
    Mounting bracket

  • Max. measurement distance

    50 m (164 ft)

  • Communication

    HART/ PROFIBUS PA
    PROFINET with Ethernet-APL
    Bluetooth® wireless
    technology and app (optional)

  • Certificates / Approvals

    IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex,
    KC Ex, INMETRO Ex, NEPSI Ex, UK Ex

  • Safety approvals

    SIL

  • Design approvals

    EU Food Contact Material (EC) 1935/2004;
    US Food Contact Material FDA CFR 21;
    Declaration of Conformity ASME B31.3;
    CRN approval

  • Marine approval

    ABS, LR, BV, RINA, DNV

  • Options

    Display, Customized settings,
    App ‘SmartBlue’ for commissioning and operation via Bluetooth
    Heartbeat for batch detection; Gas-tight implementation;
    Overvoltage protection; PWIS free

  • Application limits

    DK < 1.6
    Reduction of the max. possible measuring range due to:
    Media with poor reflective properties cone of repose
    extremely loose surface of bulk solids, e.g. bulk solids with a
    low bulk density during pneumatic filling buildup, especially of
    moist products.
    Alternative for these applications: FMR67B

Field of application
The Micropilot FMR66B belongs to the new generation of 80 GHz radar sensors. It is suitable for continuous, non-contact level measurement in simple solid applications. Wizards guide through commissioning, retesting and verification of the instrument and guarantee easy handling. The small beam angle is perfect for measurements in narrow silos. Heartbeat Technology detects unwanted anomalies, such as buildup, for increased productivity.

The Micropilot FMR66B is for free-field applications up to 50 m and provides high beam focus for vessels with many internal internals.Process connections: Thread or mounting bracketTemperature: -40 to +200 °C (-40 to 392° F)Pressure: -1 to +16 bar (-14.5 to +266 psi)Maximum measuring range: 50 m (164 ft)Accuracy: ±3 mm (0.12 in)W-Band: 80 GHzInternational explosion protection certificates, SIL, ship approvals, 5- or 10-point factory calibration certificate

Benefits
Easy handling through intuitive operation and wizards, for commissioning and verificationEasier troubleshooting thanks to recommended actions in the displaySafety by Design: Device development according to IEC 61508Increased productivity because of process monitoring, verification and diagnostics during operation with Heartbeat TechnologyEasy device integration into asset management systems through digital communication

Micropilot FMR63B – 80 GHz radar sensor

More simplicity with the specialist for hygienic applications

  • Measuring principle

    Level radar

  • Characteristic / Application

    Premium device for continuous non-contact level measurement
    with hygienic requirements (ASME BPE, USP Class VI);

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning;
    Operation and maintenance with SmartBlue app;
    HistoROM;
    RFID TAG for easy identification;
    Very narrow beam angle

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA)
    PROFINET with Ethernet-APL
    Bluetooth® wireless technology

  • Frequency

    W-Band (~80 GHz)

  • Accuracy

    +/-1 mm (0.04 in)

  • Ambient temperature

    -40 °C … +85 °C (-40 °F … +185 °F)

  • Process temperature

    -40 °C … +200 °C (-40 °F … +392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…25 bar (363 psi)

  • Main wetted parts

    PEEK or PTFE

  • Process connection

    Thread:
    M24

  • Process connection hygienic

    NEUMO BioControl;
    Slotted-nut DIN11851;
    Varivent;
    Tri-Clamp ISO2852

  • Max. measurement distance

    80 m (262 ft)

  • Communication

    HART/ PROFIBUS PA
    PROFINET with Ethernet-APL
    Bluetooth® wireless
    technology and app (optional)

  • Certificates / Approvals

    IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex,
    INMETRO Ex, NEPSI Ex, UK Ex;

  • Safety approvals

    Overfill protection WHG;
    KTW drinking water approval W270;
    NSF/ANSI 61 drinking water approval;
    SIL 2/ SIL 3

  • Design approvals

    Acceptance test certificate 3.1, EN10204;
    EU Food Contact Material (EC) 1935/2004;
    US Food Contact Material FDA CFR 21;
    Declaration of Conformity ASME B31.3;
    Conformity to cGMP;
    CoC ASME BPE;
    CRN approval

  • Hygienic approvals

    3-A;
    EHEDG;
    CoC-ASME BPE

  • Options

    Display,
    Customized settings,
    App ‘SmartBlue’ for commissioning and operation via Bluetooth
    Gas-tight implementation;
    Overvoltage protection;
    PWIS free

  • Application limits

    Process temp. > 200°C (392°F) -> FMR62
    Strong foam, stilling well and bypass (>10 m) -> FMR5x,FMP5x

Field of application
Micropilot FMR63B is part of the new generation of 80 GHz radar sensors. Thanks to its complete hygienic design it is suitable for continuous non-contact level measurement in hygienic applications. Wizards guide users through commissioning, proof tests and verification of the devices and thus guarantee a simple operation. Heartbeat Technology offers verification and monitoring functions to identify anomalies or checking the measurement accuracy.

The Micropilot FMR63B is for free space applications up to 80m and offers high beam focusing for vessels with many internal fittings. Process connections: M24 adapters and hygienic process connectionsTemperature: –40 to +200 °C (-40 to 392° F)Pressure: –1 to +25 bar (-14.5 to +362.6 psi)Maximum measuring range: 80 m (164 ft)Accuracy: ±1 mm (0.04 in) W-band: 80 GHzEHEDG, 3-A, ASME BPE, International explosion protection certificates, 5- or 10-point linearity protocol

Benefits
Fulfils highest compliance requirements of the industry Easy handling through intuitive operation and wizards, for commissioning and verificationIncreased productivity thanks to process monitoring, verification also of the radar´s accuracy and diagnostics in the running process with Heartbeat Technology Simple Display of device status – A change in the backlighting from green to red highlights errors immediately Simple device integration into asset management systems through digital communication

Micropilot FMR60B – 80 GHz radar sensor

More simplicity for your application

  • Measuring principle

    Level radar

  • Characteristic / Application

    For simple continuous non-contact level measurements in
    liquids, pastes, and slurries; Not influenced by changing media,
    temperature differences, gas phases or steam;
    For vessels with many internals

  • Specialities

    Heartbeat Technology;
    SIL 2 according to IEC 61508;
    Bluetooth® commissioning;
    Operation and maintenance with SmartBlue App;
    HistoROM;
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA)
    PROFINET with Ethernet-APL
    Bluetooth® wireless technology

  • Frequency

    W-Band (~80 GHz)

  • Accuracy

    +/-1 mm (0.04 in)

  • Ambient temperature

    -40 … +85 °C (-40 … +185 °F)

  • Process temperature

    -40 … +200 °C (-40 … +392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…20 bar (290 psi)

  • Main wetted parts

    PVDF, PTFE or PEEK

  • Process connection

    Thread: G3/4″ and 1-1/2″, MNPT 3/4″ and 1-1/2″;
    Flange: UNI DN80…DN150;
    Mounting bracket

  • Max. measurement distance

    50 m (164 ft)

  • Communication

    HART/ PROFIBUS PA
    PROFINET with Ethernet-APL
    Bluetooth® wireless
    technology and app (optional)

  • Certificates / Approvals

    IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex,
    INMETRO Ex, NEPSI Ex, UK Ex

  • Safety approvals

    Overfill protection WHG;
    SIL 2

  • Design approvals

    Acceptance test certificate 3.1, EN10204;
    EU Food Contact Material (EC) 1935/2004;
    US Food Contact Material FDA CFR 21;
    Declaration of Conformity ASME B31.3;
    AD2000;
    PMI test;
    CRN approval

  • Marine approval

    ABS, LR, BV, RINA, DNV

  • Options

    Display,
    Customized settings,
    App ‘SmartBlue’ for commissioning
    and operation via Bluetooth
    Gas-tight implementation;
    Overvoltage protection;
    PWIS free

  • Application limits

    Process temp. <-40°C (-40°F) or > 200°C (392°F) -> FMR62B
    Very aggressive media -> FMR62B
    Turbulences, stilling well and bypass -> FMR62B
    Strong foam and interfaces –> FMP5x

Field of application
Micropilot FMR60B is part of the new generation of 80 GHz radar sensors. It is used for continuous non-contact level measurement in simple liquid applications with small process connections. Wizards guide users through commissioning, proof tests and verification of the devices and thus guarantee a simple operation. Heartbeat Technology offers verification and monitoring functions to identify anomalies for more safety and increased productivity.

Micropilot FMR60B is suitable for free-space applications up to 50m and offers high beam focusing for vessels with many internal fittings. Process connections: Threads and flangesTemperature: –40 to +200 °C (-40 to 392° F)Pressure: –1 bis +20 bar (-14.5 to +290 psi)Maximum measuring range: 50 m (164 ft)Accuracy: ±1 mm (0.04 in) W-band: 80 GHzInternational explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5- or 10-point factory calibration certificate

Benefits
Easy handling through intuitive operation and wizards, for commissioning and verificationEasier troubleshooting through recommended actions shown on the display Reduction of systematic errors through guided SIL-locking, verification and proof testing Safety by design: Device development according to IEC 61508 Increased productivity thanks to process monitoring, verification and diagnostics in the running process with Heartbeat Technology

Radar measurement Time-of-Flight Micropilot FMR57

The standard sensor for highest demands in bulk solids level measurement

  • Measuring principle

    Level radar solid

  • Characteristic / Application

    For highest demands in measuring tasks of bulk solids:
    Reliable, non-contact level measurement in high silos, bunkers or stockpiles also under extreme conditions like strongly dusting and build-up forming media

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi- Echo Tracking,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART),
    Bluetooth® wireless technology and App (optional)

  • Frequency

    K-band (~26 GHz)

  • Antenna

    Parabolic DN200/8″, DN250/10″
    Horn DN80/3″, DN100/4″

  • Accuracy

    +/- 3 mm (0.12 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+400 °C
    (-40…+752 °F)

  • Process pressure / max. overpressure limit

    Vacuum…16 bar
    (Vacuum…232 psi)

  • Main wetted parts

    316L, PEEK, PTFE, Polyamid

  • Process connection

    Thread:
    MNPT 1 1/2, R 1 1/2
    Flange:
    DN80…DN100,
    ASME 3″…4″,
    JIS 10K,
    UNI DN100/8″…DN250/10″

  • Max. measurement distance

    70 m (230 ft)

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, JPN Ex, EAC, UK Ex

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    Display,
    Customized parameterization,
    Remote operation via SmartBlue App using Bluetooth®,
    Antenna extension,
    PWIS free

  • Application limits

    Dk < 1.6
    Reduction of the max. possible measuring range through:
    Media with poor reflection properties
    Angle of repose
    Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling
    Build-up, above all of moist products

Field of application
Micropilot FMR57 is the sensor for the highest demands in bulk solids and best suited for measurements in high silos, bunkers or stockpiles. The parabolic antenna facilitates very small emitting angles and thus the measurement in slim silos. Micropilot free space radar is used for continuous, non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.

Horn or parabolic antenna. Thanks to the additional air purge connection even strongly dusting and build-up forming media do not present any problem.
Process connections: Thread or flange
Temperature: -40 to +400°C (–40 to 752°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: 70m (230ft)
K-band: 26GHz
International explosion protection certificates, SIL, 5-point linearity protocol

Benefits
Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)HistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluationHeartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)Reliable measurement even for changing product and process conditionsWorld’s easiest proof test concept for SIL and WHG saves time and cost

Radar measurement Time-of-Flight Micropilot FMR52

For level measurement in aggressive liquids or applications with hygiene requirements

  • Measuring principle

    Level radar

  • Characteristic / Application

    Premium device for continuous non-contact level measurement, in which aggressive media are used as well as for highest hygiene requirements (ASME BPE, USP Class VI);
    Flush mounted, fully PTFE filled horn antenna

  • Specialities

    Heartbeat Technology,
    SIL 2 according to IEC 61508,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi-Echo Tracking,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 2 mm (0.08 in)

  • Ambient temperature

    -50…+80 °C
    (-58…+176 °F)

  • Process temperature

    -196…+200 °C
    (-321…+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…25 bar
    (Vacuum…363 psi)

  • Main wetted parts

    PTFE

  • Process connection

    Flange:
    DN50…DN150
    ASME 2″…6″
    JIS 10K

  • Process connection hygienic

    Tri-Clamp ISO2852
    DIN11851

  • Max. measurement distance

    Standard: 40 m (131 ft)
    With advanced dynamics: 60 m (197 ft)

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    ASME B31.3
    AD2000

  • Hygienic approvals

    3A, EHEDG
    CoC ASME-BPE

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    Display,
    Customized parameterization,
    Remote operation via SmartBlue App using Bluetooth®,
    Gas-tight feed through,
    PWIS free

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application
    Ammoniacal gas phase:
    FMR54 in stilling well
    Strong build-up formation:
    FMR54 with air purge
    Custody transfer measurement:
    FMR5xx

Field of application
For applications in aggressive liquids Micropilot FMR52 offers extraordinary advantages with its completely PTFE-filled and flush-mounted horn antenna. The FMR52 is also the sensor for hygiene-sensitive applications in the food and life sciences industry – ASME BPE, USP Class VI, 3-A and EHEDG approvals. Micropilot is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Flush-mounted, completely PTFE-encapsulated horn antenna.
Process connections: Flush-mounted with cladded flange, process connections for hygiene requirements (Tri-Clamp, 11851)
Temperature: -196 to +200°C (-320,8 to +392°F)
Pressure: -1 to +25bar (-14.5 to +362psi)
Maximum measuring range: 40m (131ft), 60m (197ft) for enhanced dynamics
Accuracy: ±2mm
K-band: 26GHz
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval

Benefits
Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)Reliable non-contact measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluationHeartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test concept for SIL and WHG saves time and cost

Radar measurement Time-of-Flight Micropilot FMR20

Level measurement of liquids and solids in all industries

  • Measuring principle

    Level radar

  • Characteristic / Application

    Water & Wastewater (e.g. basins / channels / rivers / dams / lift stations / storm water basins / pump control)
    Utility applications in all industries
    Storage tanks

  • Specialities

    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App

  • Supply / Communication

    2-wire (HART, 4…20 mA, Modbus),
    Bluetooth® wireless technology and App (optional)

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 2 mm (0,08″)

  • Ambient temperature

    -40…+80°C (-40…+176°F)

  • Process temperature

    -40…+80°C (-40…+176°F)

  • Process pressure / max. overpressure limit

    -1…3 bar (-14,5…43 psi)

  • Main wetted parts

    PVDF, PBT

  • Process connection

    Thread:
    G1″, NPT1″; G1 1/2″, NPT1 1/2″, G2″, NPT2″,
    Flange:
    UNI DN80….DN150 (3″…6″)

Radar measurement Time-of-Flight Micropilot FMR10

Level measurement in liquids for water & wastewater and utilities in all industries

  • Measuring principle

    Level radar

  • Characteristic / Application

    Simple applications in Water & Wastewater
    Utility applications in all industries
    Easy storage tanks

  • Specialities

    Bluetooth® commissioning,
    Operation and maintenance via SmartBlue App

  • Supply / Communication

    2-wire (4…20 mA)
    Bluetooth® wireless technology and App

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 5 mm (0,2″)

  • Process temperature

    -40…+60°C
    (-40…+140°F)

  • Process pressure / max. overpressure limit

    -1…3 bar (-14,50…43 psi)

  • Main wetted parts

    PVDF, PBT

  • Process connection

    Thread:
    G1″, NPT1″; G1 1/2″, NPT1 1/2″

  • Max. measurement distance

    Standard: 8 m (26.2 ft)
    With flooding protection tube: 12 m (39.4 ft)

  • Communication

    Bluetooth® wireless technology

  • Certificates / Approvals

    CSA C/US

  • Options

    Flooding protection tube
    Different mounting possibilities

  • Application limits

    DK < 4:
    FMR5x;
    Turbulent surfaces:
    FMR5x;
    Ammoniacal gas phase:
    FMR54 in stilling well;
    Strong build-up formation:
    FMR54 with air purge;
    Only PTFE resistant:
    FMR52;
    Custody transfer measurement:
    FMR5xx or NMR8x

Field of application
Micropilot FMR10 offers continuous non-contact level measurement and is a perfect application fit for the water & wastewater industry and utilities across all industries. FMR10 belongs to the first radars with Bluetooth® commissioning, operation and maintenance app. Signal curves can be shown via app on every Bluetooth®-enabled smartphone or tablet (iOS, Android). With the compact design, thanks to unique chip, the device is ideal for limited space applications.

Radar for continuous level measurement in liquids. For use in storage tanks, open basins, pump/lift stations or sewer management.Process connections: ThreadsProcess temperature: -40 to +60°C (-40 to +140°F)Process pressure: -1 to +3bar (-14.5 to +43psi)Maximum measuring range: up to 12m (39ft) with mounted flooding tube protectionAccuracy: ±5mm (0.2″)Measuring frequency: 26GHz

Benefits
Non-contact radar with Bluetooth® commissioning, operation and maintenance app Most compact radar due to unique radar chip design offering perfect fit in limited space applications Best price-performance-ratio radar Perfect application fit for water & wastewater and utilities in all industries (IP66, IP68 / NEMA4x /6P)Full PVDF body to resist outdoor conditions, sealed wiring and fully potted electronics eliminates water ingress and allows operation under harsh environmental conditions Easy setup with three main parameters suits for most applications Simple, safe and secure wireless remote access via Bluetooth®

Translate »